Finite element investigation of the effect of spina bifida on loading of the vertebral isthmus

Background: Spondylolysis (SL) of the lower lumbar spine is frequently associated with spina bifida occulta (SBO). There has not been any study that has demonstrated biomechanical or genetic predispositions to explain the coexistence of these two pathologies. In axial rotation, the intact vertebral...

Full description

Bibliographic Details
Main Authors: Quah, Conal, Yeoman, Mark S., Cizinauskas, Andrius, Cooper, Kevin, McNally, Donal, Boszczyk, Bronek
Format: Article
Published: Elsevier 2014
Subjects:
Online Access:https://eprints.nottingham.ac.uk/35551/
_version_ 1848795105331249152
author Quah, Conal
Yeoman, Mark S.
Cizinauskas, Andrius
Cooper, Kevin
McNally, Donal
Boszczyk, Bronek
author_facet Quah, Conal
Yeoman, Mark S.
Cizinauskas, Andrius
Cooper, Kevin
McNally, Donal
Boszczyk, Bronek
author_sort Quah, Conal
building Nottingham Research Data Repository
collection Online Access
description Background: Spondylolysis (SL) of the lower lumbar spine is frequently associated with spina bifida occulta (SBO). There has not been any study that has demonstrated biomechanical or genetic predispositions to explain the coexistence of these two pathologies. In axial rotation, the intact vertebral arch allows torsional load to be shared between the facet joints. In SBO, the load cannot be shared across the arch, theoretically increasing the mechanical demand of the vertebral isthmus during combined axial loading and rotation when compared to the normal state. Purpose: To test the hypothesis that fatigue failure limits will be exceeded in the case of a bifid arch, but not in the intact case, when the segment is subjected to complex loading corresponding to normal sporting activities. Study Design: Descriptive Laboratory Study. Methods: Finite element models of natural and SBO (L4-S1) including ligaments were loaded axially to 1kN and were combined with axial rotation of 3°. Bilateral stresses, alternating stresses and shear fatigue failure on intact and SBO L5 isthmus were assessed and compared. Results: Under 1kN axial load, the von Mises stresses observed in SBO and in the intact cases were very similar (differences <5MPa) having a maximum at the ventral end of the isthmus that decreases monotonically to the dorsal end. However, under 1kN axial load and rotation, the maximum von Mises stresses observed in the ipsilateral L5 isthmus in the SBO case (31MPa) was much higher than the intact case (24.2MPa) indicating a lack of load sharing across the vertebral arch in SBO. When assessing the equivalent alternating shear stress amplitude, this was found to be 22.6 MPa for the SBO case and 13.6 MPa for the intact case. From this it is estimated that shear fatigue failure will occur in less than 70,000 cycles, under repetitive axial load & rotation conditions in the SBO case, while for the intact case, fatigue failure will occur only over 10 million cycles. Conclusion: SBO predisposes spondylolysis by generating increased stresses across the inferior isthmus of the inferior articular process, specifically in combined axial rotation and anteroposterior shear. Clinical Relevance: Athletes with SBO who participate in sports that require repetitive lumbar rotation, hyperextension and/or axial loading are at a higher risk of developing spondylolysis compared to athletes with an intact spine.
first_indexed 2025-11-14T19:26:48Z
format Article
id nottingham-35551
institution University of Nottingham Malaysia Campus
institution_category Local University
last_indexed 2025-11-14T19:26:48Z
publishDate 2014
publisher Elsevier
recordtype eprints
repository_type Digital Repository
spelling nottingham-355512024-08-15T15:14:54Z https://eprints.nottingham.ac.uk/35551/ Finite element investigation of the effect of spina bifida on loading of the vertebral isthmus Quah, Conal Yeoman, Mark S. Cizinauskas, Andrius Cooper, Kevin McNally, Donal Boszczyk, Bronek Background: Spondylolysis (SL) of the lower lumbar spine is frequently associated with spina bifida occulta (SBO). There has not been any study that has demonstrated biomechanical or genetic predispositions to explain the coexistence of these two pathologies. In axial rotation, the intact vertebral arch allows torsional load to be shared between the facet joints. In SBO, the load cannot be shared across the arch, theoretically increasing the mechanical demand of the vertebral isthmus during combined axial loading and rotation when compared to the normal state. Purpose: To test the hypothesis that fatigue failure limits will be exceeded in the case of a bifid arch, but not in the intact case, when the segment is subjected to complex loading corresponding to normal sporting activities. Study Design: Descriptive Laboratory Study. Methods: Finite element models of natural and SBO (L4-S1) including ligaments were loaded axially to 1kN and were combined with axial rotation of 3°. Bilateral stresses, alternating stresses and shear fatigue failure on intact and SBO L5 isthmus were assessed and compared. Results: Under 1kN axial load, the von Mises stresses observed in SBO and in the intact cases were very similar (differences <5MPa) having a maximum at the ventral end of the isthmus that decreases monotonically to the dorsal end. However, under 1kN axial load and rotation, the maximum von Mises stresses observed in the ipsilateral L5 isthmus in the SBO case (31MPa) was much higher than the intact case (24.2MPa) indicating a lack of load sharing across the vertebral arch in SBO. When assessing the equivalent alternating shear stress amplitude, this was found to be 22.6 MPa for the SBO case and 13.6 MPa for the intact case. From this it is estimated that shear fatigue failure will occur in less than 70,000 cycles, under repetitive axial load & rotation conditions in the SBO case, while for the intact case, fatigue failure will occur only over 10 million cycles. Conclusion: SBO predisposes spondylolysis by generating increased stresses across the inferior isthmus of the inferior articular process, specifically in combined axial rotation and anteroposterior shear. Clinical Relevance: Athletes with SBO who participate in sports that require repetitive lumbar rotation, hyperextension and/or axial loading are at a higher risk of developing spondylolysis compared to athletes with an intact spine. Elsevier 2014-04-01 Article NonPeerReviewed Quah, Conal, Yeoman, Mark S., Cizinauskas, Andrius, Cooper, Kevin, McNally, Donal and Boszczyk, Bronek (2014) Finite element investigation of the effect of spina bifida on loading of the vertebral isthmus. Spine Journal, 14 (4). pp. 675-682. ISSN 1529-9430 Spina bifida occulta; Spondylolysis; Finite element analysis; Pars interarticularis fatigue fracture; Lumbar spine; Laminectomy http://www.sciencedirect.com/science/article/pii/S1529943013014873 doi:10.1016/j.spinee.2013.08.040 doi:10.1016/j.spinee.2013.08.040
spellingShingle Spina bifida occulta; Spondylolysis; Finite element analysis; Pars interarticularis fatigue fracture; Lumbar spine; Laminectomy
Quah, Conal
Yeoman, Mark S.
Cizinauskas, Andrius
Cooper, Kevin
McNally, Donal
Boszczyk, Bronek
Finite element investigation of the effect of spina bifida on loading of the vertebral isthmus
title Finite element investigation of the effect of spina bifida on loading of the vertebral isthmus
title_full Finite element investigation of the effect of spina bifida on loading of the vertebral isthmus
title_fullStr Finite element investigation of the effect of spina bifida on loading of the vertebral isthmus
title_full_unstemmed Finite element investigation of the effect of spina bifida on loading of the vertebral isthmus
title_short Finite element investigation of the effect of spina bifida on loading of the vertebral isthmus
title_sort finite element investigation of the effect of spina bifida on loading of the vertebral isthmus
topic Spina bifida occulta; Spondylolysis; Finite element analysis; Pars interarticularis fatigue fracture; Lumbar spine; Laminectomy
url https://eprints.nottingham.ac.uk/35551/
https://eprints.nottingham.ac.uk/35551/
https://eprints.nottingham.ac.uk/35551/