Speech-evoked activation in adult temporal cortex measured using functional near-infrared spectroscopy (fNIRS): Are the measurements reliable?

Functional near-infrared spectroscopy (fNIRS) is a silent, non-invasive neuroimaging technique that is potentially well suited to auditory research. However, the reliability of auditory-evoked activation measured using fNIRS is largely unknown. The present study investigated the test-retest reliabil...

Full description

Bibliographic Details
Main Authors: Wiggins, Ian M., Anderson, Carly A., Kitterick, Pádraig T., Hartley, Douglas E.H.
Format: Article
Published: Elsevier 2016
Subjects:
Online Access:https://eprints.nottingham.ac.uk/35468/
_version_ 1848795085175521280
author Wiggins, Ian M.
Anderson, Carly A.
Kitterick, Pádraig T.
Hartley, Douglas E.H.
author_facet Wiggins, Ian M.
Anderson, Carly A.
Kitterick, Pádraig T.
Hartley, Douglas E.H.
author_sort Wiggins, Ian M.
building Nottingham Research Data Repository
collection Online Access
description Functional near-infrared spectroscopy (fNIRS) is a silent, non-invasive neuroimaging technique that is potentially well suited to auditory research. However, the reliability of auditory-evoked activation measured using fNIRS is largely unknown. The present study investigated the test-retest reliability of speech-evoked fNIRS responses in normally-hearing adults. Seventeen participants underwent fNIRS imaging in two sessions separated by three months. In a block design, participants were presented with auditory speech, visual speech (silent speechreading), and audiovisual speech conditions. Optode arrays were placed bilaterally over the temporal lobes, targeting auditory brain regions. A range of established metrics was used to quantify the reproducibility of cortical activation patterns, as well as the amplitude and time course of the haemodynamic response within predefined regions of interest. The use of a signal processing algorithm designed to reduce the influence of systemic physiological signals was found to be crucial to achieving reliable detection of significant activation at the group level. For auditory speech (with or without visual cues), reliability was good to excellent at the group level, but highly variable among individuals. Temporal-lobe activation in response to visual speech was less reliable, especially in the right hemisphere. Consistent with previous reports, fNIRS reliability was improved by averaging across a small number of channels overlying a cortical region of interest. Overall, the present results confirm that fNIRS can measure speech-evoked auditory responses in adults that are highly reliable at the group level, and indicate that signal processing to reduce physiological noise may substantially improve the reliability of fNIRS measurements.
first_indexed 2025-11-14T19:26:28Z
format Article
id nottingham-35468
institution University of Nottingham Malaysia Campus
institution_category Local University
last_indexed 2025-11-14T19:26:28Z
publishDate 2016
publisher Elsevier
recordtype eprints
repository_type Digital Repository
spelling nottingham-354682020-05-04T18:00:28Z https://eprints.nottingham.ac.uk/35468/ Speech-evoked activation in adult temporal cortex measured using functional near-infrared spectroscopy (fNIRS): Are the measurements reliable? Wiggins, Ian M. Anderson, Carly A. Kitterick, Pádraig T. Hartley, Douglas E.H. Functional near-infrared spectroscopy (fNIRS) is a silent, non-invasive neuroimaging technique that is potentially well suited to auditory research. However, the reliability of auditory-evoked activation measured using fNIRS is largely unknown. The present study investigated the test-retest reliability of speech-evoked fNIRS responses in normally-hearing adults. Seventeen participants underwent fNIRS imaging in two sessions separated by three months. In a block design, participants were presented with auditory speech, visual speech (silent speechreading), and audiovisual speech conditions. Optode arrays were placed bilaterally over the temporal lobes, targeting auditory brain regions. A range of established metrics was used to quantify the reproducibility of cortical activation patterns, as well as the amplitude and time course of the haemodynamic response within predefined regions of interest. The use of a signal processing algorithm designed to reduce the influence of systemic physiological signals was found to be crucial to achieving reliable detection of significant activation at the group level. For auditory speech (with or without visual cues), reliability was good to excellent at the group level, but highly variable among individuals. Temporal-lobe activation in response to visual speech was less reliable, especially in the right hemisphere. Consistent with previous reports, fNIRS reliability was improved by averaging across a small number of channels overlying a cortical region of interest. Overall, the present results confirm that fNIRS can measure speech-evoked auditory responses in adults that are highly reliable at the group level, and indicate that signal processing to reduce physiological noise may substantially improve the reliability of fNIRS measurements. Elsevier 2016-07-20 Article PeerReviewed Wiggins, Ian M., Anderson, Carly A., Kitterick, Pádraig T. and Hartley, Douglas E.H. (2016) Speech-evoked activation in adult temporal cortex measured using functional near-infrared spectroscopy (fNIRS): Are the measurements reliable? Hearing Research, 339 . pp. 142-154. ISSN 1878-5891 Auditory Cortex; fNIRS; Functional Near-infrared Spectroscopy; Speech; Speechreading; Test-retest Reliability http://www.sciencedirect.com/science/article/pii/S0378595516300570 doi:10.1016/j.heares.2016.07.007 doi:10.1016/j.heares.2016.07.007
spellingShingle Auditory Cortex; fNIRS; Functional Near-infrared Spectroscopy; Speech; Speechreading; Test-retest Reliability
Wiggins, Ian M.
Anderson, Carly A.
Kitterick, Pádraig T.
Hartley, Douglas E.H.
Speech-evoked activation in adult temporal cortex measured using functional near-infrared spectroscopy (fNIRS): Are the measurements reliable?
title Speech-evoked activation in adult temporal cortex measured using functional near-infrared spectroscopy (fNIRS): Are the measurements reliable?
title_full Speech-evoked activation in adult temporal cortex measured using functional near-infrared spectroscopy (fNIRS): Are the measurements reliable?
title_fullStr Speech-evoked activation in adult temporal cortex measured using functional near-infrared spectroscopy (fNIRS): Are the measurements reliable?
title_full_unstemmed Speech-evoked activation in adult temporal cortex measured using functional near-infrared spectroscopy (fNIRS): Are the measurements reliable?
title_short Speech-evoked activation in adult temporal cortex measured using functional near-infrared spectroscopy (fNIRS): Are the measurements reliable?
title_sort speech-evoked activation in adult temporal cortex measured using functional near-infrared spectroscopy (fnirs): are the measurements reliable?
topic Auditory Cortex; fNIRS; Functional Near-infrared Spectroscopy; Speech; Speechreading; Test-retest Reliability
url https://eprints.nottingham.ac.uk/35468/
https://eprints.nottingham.ac.uk/35468/
https://eprints.nottingham.ac.uk/35468/