A power electronic controlled dump load with negligible harmonics for accurate loading used in testing small wind turbines

Permanent magnet synchronous generators (PMSG) are at the core of small scale wind power generators manufactured by a wide range of manufacturers in different configurations: vertical or horizontal axis blades, with various geometries and aerodynamics of the blades; by installing these small scale w...

Full description

Bibliographic Details
Main Authors: Klumpner, Christian, Al, Baydu, Hann, David B.
Format: Conference or Workshop Item
Published: 2010
Subjects:
Online Access:https://eprints.nottingham.ac.uk/34824/
_version_ 1848794943394414592
author Klumpner, Christian
Al, Baydu
Hann, David B.
author_facet Klumpner, Christian
Al, Baydu
Hann, David B.
author_sort Klumpner, Christian
building Nottingham Research Data Repository
collection Online Access
description Permanent magnet synchronous generators (PMSG) are at the core of small scale wind power generators manufactured by a wide range of manufacturers in different configurations: vertical or horizontal axis blades, with various geometries and aerodynamics of the blades; by installing these small scale wind turbines in very large numbers at household levels, it is expected that these will make a positive contribution to the increase of renewable energy generation, reducing the use of fossil fuels that are blamed for climate change. However, a proper evaluation of the technical specification of these small scale wind generators in various weather conditions is necessary in order to assess the full potential of benefits. This paper reports on the implementation and testing of a power electronic dump load that allows continuously adjustable loading of a PMSG with sinusoidal currents and have the capability to self synchronize to its frequency/speed whilst avoiding transient/loosing of synchronism.
first_indexed 2025-11-14T19:24:13Z
format Conference or Workshop Item
id nottingham-34824
institution University of Nottingham Malaysia Campus
institution_category Local University
last_indexed 2025-11-14T19:24:13Z
publishDate 2010
recordtype eprints
repository_type Digital Repository
spelling nottingham-348242020-05-04T16:29:07Z https://eprints.nottingham.ac.uk/34824/ A power electronic controlled dump load with negligible harmonics for accurate loading used in testing small wind turbines Klumpner, Christian Al, Baydu Hann, David B. Permanent magnet synchronous generators (PMSG) are at the core of small scale wind power generators manufactured by a wide range of manufacturers in different configurations: vertical or horizontal axis blades, with various geometries and aerodynamics of the blades; by installing these small scale wind turbines in very large numbers at household levels, it is expected that these will make a positive contribution to the increase of renewable energy generation, reducing the use of fossil fuels that are blamed for climate change. However, a proper evaluation of the technical specification of these small scale wind generators in various weather conditions is necessary in order to assess the full potential of benefits. This paper reports on the implementation and testing of a power electronic dump load that allows continuously adjustable loading of a PMSG with sinusoidal currents and have the capability to self synchronize to its frequency/speed whilst avoiding transient/loosing of synchronism. 2010-03-24 Conference or Workshop Item PeerReviewed Klumpner, Christian, Al, Baydu and Hann, David B. (2010) A power electronic controlled dump load with negligible harmonics for accurate loading used in testing small wind turbines. In: 2010 IEEE International Symposium in Industrial Electronics (ISIE 2010), 4-7 Jul 2010, Bari, Italy. Generators Harmonic Analysis Resistance Resistors Stators Transistors Wind Turbines http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=5637240 10.1109/ISIE.2010.5637240 10.1109/ISIE.2010.5637240 10.1109/ISIE.2010.5637240
spellingShingle Generators
Harmonic Analysis
Resistance
Resistors
Stators
Transistors
Wind Turbines
Klumpner, Christian
Al, Baydu
Hann, David B.
A power electronic controlled dump load with negligible harmonics for accurate loading used in testing small wind turbines
title A power electronic controlled dump load with negligible harmonics for accurate loading used in testing small wind turbines
title_full A power electronic controlled dump load with negligible harmonics for accurate loading used in testing small wind turbines
title_fullStr A power electronic controlled dump load with negligible harmonics for accurate loading used in testing small wind turbines
title_full_unstemmed A power electronic controlled dump load with negligible harmonics for accurate loading used in testing small wind turbines
title_short A power electronic controlled dump load with negligible harmonics for accurate loading used in testing small wind turbines
title_sort power electronic controlled dump load with negligible harmonics for accurate loading used in testing small wind turbines
topic Generators
Harmonic Analysis
Resistance
Resistors
Stators
Transistors
Wind Turbines
url https://eprints.nottingham.ac.uk/34824/
https://eprints.nottingham.ac.uk/34824/
https://eprints.nottingham.ac.uk/34824/