Performance of T-stub to CFT joints using blind bolts with headed anchors

This paper assesses the performance of a newly developed blind bolt, intended for use in constructing bolted moment-resisting connections to concrete-filled tubular steel profiles. A total of ten connection tests are reported, with each configuration having been subjected to a predominantly tensile...

Full description

Bibliographic Details
Main Authors: Tizani, Walid, Pitrakkos, Theodoros
Format: Article
Published: American Society of Civil Engineers 2015
Online Access:https://eprints.nottingham.ac.uk/34015/
_version_ 1848794756470013952
author Tizani, Walid
Pitrakkos, Theodoros
author_facet Tizani, Walid
Pitrakkos, Theodoros
author_sort Tizani, Walid
building Nottingham Research Data Repository
collection Online Access
description This paper assesses the performance of a newly developed blind bolt, intended for use in constructing bolted moment-resisting connections to concrete-filled tubular steel profiles. A total of ten connection tests are reported, with each configuration having been subjected to a predominantly tensile force in a representation of the tension region of a typical moment connection. The test variables included type of fastener, addition of concrete to the tube, strength of the concrete, spacing among bolts, and bolt class. On the basis of reformability response, the benefits of filling the tubular member with concrete are highlighted. The favorable performance that results from using a relatively, high-grade concrete infill is also highlighted. The addition of a concrete infill to the tube stiffens and strengthens the otherwise relatively flexible tube walls, enhancing overall connection behavior in terms of stiffness, strength, and ductility. The performance of connections to concrete-filled tubular steel profiles using blind bolts with headed anchors is shown to be suitable for moment-resisting construction.
first_indexed 2025-11-14T19:21:15Z
format Article
id nottingham-34015
institution University of Nottingham Malaysia Campus
institution_category Local University
last_indexed 2025-11-14T19:21:15Z
publishDate 2015
publisher American Society of Civil Engineers
recordtype eprints
repository_type Digital Repository
spelling nottingham-340152020-05-04T17:15:57Z https://eprints.nottingham.ac.uk/34015/ Performance of T-stub to CFT joints using blind bolts with headed anchors Tizani, Walid Pitrakkos, Theodoros This paper assesses the performance of a newly developed blind bolt, intended for use in constructing bolted moment-resisting connections to concrete-filled tubular steel profiles. A total of ten connection tests are reported, with each configuration having been subjected to a predominantly tensile force in a representation of the tension region of a typical moment connection. The test variables included type of fastener, addition of concrete to the tube, strength of the concrete, spacing among bolts, and bolt class. On the basis of reformability response, the benefits of filling the tubular member with concrete are highlighted. The favorable performance that results from using a relatively, high-grade concrete infill is also highlighted. The addition of a concrete infill to the tube stiffens and strengthens the otherwise relatively flexible tube walls, enhancing overall connection behavior in terms of stiffness, strength, and ductility. The performance of connections to concrete-filled tubular steel profiles using blind bolts with headed anchors is shown to be suitable for moment-resisting construction. American Society of Civil Engineers 2015-10-01 Article PeerReviewed Tizani, Walid and Pitrakkos, Theodoros (2015) Performance of T-stub to CFT joints using blind bolts with headed anchors. Journal of Structural Engineering, 141 (10). 04015001. ISSN 0733-9445 http://dx.doi.org/10.1061/(ASCE)ST.1943-541X.0001169 doi:10.1061/(ASCE)ST.1943-541X.0001169 doi:10.1061/(ASCE)ST.1943-541X.0001169
spellingShingle Tizani, Walid
Pitrakkos, Theodoros
Performance of T-stub to CFT joints using blind bolts with headed anchors
title Performance of T-stub to CFT joints using blind bolts with headed anchors
title_full Performance of T-stub to CFT joints using blind bolts with headed anchors
title_fullStr Performance of T-stub to CFT joints using blind bolts with headed anchors
title_full_unstemmed Performance of T-stub to CFT joints using blind bolts with headed anchors
title_short Performance of T-stub to CFT joints using blind bolts with headed anchors
title_sort performance of t-stub to cft joints using blind bolts with headed anchors
url https://eprints.nottingham.ac.uk/34015/
https://eprints.nottingham.ac.uk/34015/
https://eprints.nottingham.ac.uk/34015/