Resonant–Repetitive combined control for stand-alone power supply unit
This paper investigates a combined resonant–repetitive (RR) control structure for a three-phase four-leg DC/AC converter power supply. The RR control configuration is com-posed by a resonant controller tuned at the system fundamental frequency working in conjunction with a plug-in-type repetitive con...
| Main Authors: | , , , , |
|---|---|
| Format: | Article |
| Published: |
IEEE
2015
|
| Subjects: | |
| Online Access: | https://eprints.nottingham.ac.uk/33129/ |
| _version_ | 1848794564004937728 |
|---|---|
| author | Lidozzi, Alessandro Solero, Luca Crescimbini, Fabio Ji, Chao Zanchetta, Pericle |
| author_facet | Lidozzi, Alessandro Solero, Luca Crescimbini, Fabio Ji, Chao Zanchetta, Pericle |
| author_sort | Lidozzi, Alessandro |
| building | Nottingham Research Data Repository |
| collection | Online Access |
| description | This paper investigates a combined resonant–repetitive (RR) control structure for a three-phase four-leg DC/AC converter power supply. The RR control configuration is com-posed by a resonant controller tuned at the system fundamental frequency working in conjunction with a plug-in-type repetitive controller. The resonant part of the control scheme is used to as-sure prompt tracking of the inverter output voltage and to achieve as fast as possible system response to load variations; to this pur-pose, it is tuned at the fundamental frequency. At the same time,the resonant controller is able to stabilize the system without the necessity of any further additional controller; the repetitive part of the scheme is implemented for the fine regulation at the system harmonic frequencies. The proposed control configuration is used to regulate the power supply output voltage, providing very good tracking of the output voltage reference even in the presence of anon linear load. Experimental validation from a 40-kVA converter prototype is presented to validate the operation of the proposed converter and control. |
| first_indexed | 2025-11-14T19:18:11Z |
| format | Article |
| id | nottingham-33129 |
| institution | University of Nottingham Malaysia Campus |
| institution_category | Local University |
| last_indexed | 2025-11-14T19:18:11Z |
| publishDate | 2015 |
| publisher | IEEE |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | nottingham-331292020-05-04T17:22:22Z https://eprints.nottingham.ac.uk/33129/ Resonant–Repetitive combined control for stand-alone power supply unit Lidozzi, Alessandro Solero, Luca Crescimbini, Fabio Ji, Chao Zanchetta, Pericle This paper investigates a combined resonant–repetitive (RR) control structure for a three-phase four-leg DC/AC converter power supply. The RR control configuration is com-posed by a resonant controller tuned at the system fundamental frequency working in conjunction with a plug-in-type repetitive controller. The resonant part of the control scheme is used to as-sure prompt tracking of the inverter output voltage and to achieve as fast as possible system response to load variations; to this pur-pose, it is tuned at the fundamental frequency. At the same time,the resonant controller is able to stabilize the system without the necessity of any further additional controller; the repetitive part of the scheme is implemented for the fine regulation at the system harmonic frequencies. The proposed control configuration is used to regulate the power supply output voltage, providing very good tracking of the output voltage reference even in the presence of anon linear load. Experimental validation from a 40-kVA converter prototype is presented to validate the operation of the proposed converter and control. IEEE 2015-11-19 Article PeerReviewed Lidozzi, Alessandro, Solero, Luca, Crescimbini, Fabio, Ji, Chao and Zanchetta, Pericle (2015) Resonant–Repetitive combined control for stand-alone power supply unit. IEEE Transactions on Industry Applications, 51 (6). pp. 4653-4663. ISSN 0093-9994 Distributed power generation DC-AC power converters harmonic distortion repetitive control resonant control unbalanced loads. http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7163582 doi:10.1109/TIA.2015.2458960 doi:10.1109/TIA.2015.2458960 |
| spellingShingle | Distributed power generation DC-AC power converters harmonic distortion repetitive control resonant control unbalanced loads. Lidozzi, Alessandro Solero, Luca Crescimbini, Fabio Ji, Chao Zanchetta, Pericle Resonant–Repetitive combined control for stand-alone power supply unit |
| title | Resonant–Repetitive combined control for stand-alone power supply unit |
| title_full | Resonant–Repetitive combined control for stand-alone power supply unit |
| title_fullStr | Resonant–Repetitive combined control for stand-alone power supply unit |
| title_full_unstemmed | Resonant–Repetitive combined control for stand-alone power supply unit |
| title_short | Resonant–Repetitive combined control for stand-alone power supply unit |
| title_sort | resonant–repetitive combined control for stand-alone power supply unit |
| topic | Distributed power generation DC-AC power converters harmonic distortion repetitive control resonant control unbalanced loads. |
| url | https://eprints.nottingham.ac.uk/33129/ https://eprints.nottingham.ac.uk/33129/ https://eprints.nottingham.ac.uk/33129/ |