A novel oximeter

The measurement of oxygen saturation SO2 is one of the vital signs relied on by the medical profession. Pulse oximeters are widely used in many branches of medicine; and are the most widely used method of assessing oxygen saturation. However they can only be applied to an extremity (usually a finger...

Full description

Bibliographic Details
Main Author: Rodmell, Paul Irvin
Format: Thesis (University of Nottingham only)
Language:English
Published: 2006
Subjects:
Online Access:https://eprints.nottingham.ac.uk/31151/
_version_ 1848794137037373440
author Rodmell, Paul Irvin
author_facet Rodmell, Paul Irvin
author_sort Rodmell, Paul Irvin
building Nottingham Research Data Repository
collection Online Access
description The measurement of oxygen saturation SO2 is one of the vital signs relied on by the medical profession. Pulse oximeters are widely used in many branches of medicine; and are the most widely used method of assessing oxygen saturation. However they can only be applied to an extremity (usually a finger or toe), need calibration, and are known to be inaccurate under certain conditions. The object of this research was to develop an oximeter, that does not require a pulsatile signal, (and so can be used anywhere on the body); can be used in either transmission of reflective mode; does not require calibration; and does not suffer from the known problems of pulse oximeters. The instrument must work with reflected light, and so the first step was to develop a Monte Carlo simulation of the Attenuation spectra, for visible light, from a scattering media (tissue). A mathematical model of the attenuation surface had then to be found, and its effect on the absorbtion spectra of oxyhemoglobin HbO2 and de-oxyhemoglobin Hb understood. Then the oxygen saturation the ratio of HbO2 to total haemoglobin could be recovered. Methods of computing oxygen saturation from the raw reflectance spectra were devised and then tested with single reflection spectra, the results indicate that a low cost instrument could be developed. The technique was applied to images from a hyper-spectral camera, this instrument takes a full spectrum at each pixel of an image, and enabled an oxygen saturation map for large areas of the body to be produced. The technique is being used with AstraZenca Ltd as a bio marker skin for irritation studies
first_indexed 2025-11-14T19:11:24Z
format Thesis (University of Nottingham only)
id nottingham-31151
institution University of Nottingham Malaysia Campus
institution_category Local University
language English
last_indexed 2025-11-14T19:11:24Z
publishDate 2006
recordtype eprints
repository_type Digital Repository
spelling nottingham-311512025-02-28T11:45:57Z https://eprints.nottingham.ac.uk/31151/ A novel oximeter Rodmell, Paul Irvin The measurement of oxygen saturation SO2 is one of the vital signs relied on by the medical profession. Pulse oximeters are widely used in many branches of medicine; and are the most widely used method of assessing oxygen saturation. However they can only be applied to an extremity (usually a finger or toe), need calibration, and are known to be inaccurate under certain conditions. The object of this research was to develop an oximeter, that does not require a pulsatile signal, (and so can be used anywhere on the body); can be used in either transmission of reflective mode; does not require calibration; and does not suffer from the known problems of pulse oximeters. The instrument must work with reflected light, and so the first step was to develop a Monte Carlo simulation of the Attenuation spectra, for visible light, from a scattering media (tissue). A mathematical model of the attenuation surface had then to be found, and its effect on the absorbtion spectra of oxyhemoglobin HbO2 and de-oxyhemoglobin Hb understood. Then the oxygen saturation the ratio of HbO2 to total haemoglobin could be recovered. Methods of computing oxygen saturation from the raw reflectance spectra were devised and then tested with single reflection spectra, the results indicate that a low cost instrument could be developed. The technique was applied to images from a hyper-spectral camera, this instrument takes a full spectrum at each pixel of an image, and enabled an oxygen saturation map for large areas of the body to be produced. The technique is being used with AstraZenca Ltd as a bio marker skin for irritation studies 2006-07-14 Thesis (University of Nottingham only) NonPeerReviewed application/pdf en arr https://eprints.nottingham.ac.uk/31151/1/537669.pdf Rodmell, Paul Irvin (2006) A novel oximeter. PhD thesis, University of Nottingham. Oximetry Oxygen saturation
spellingShingle Oximetry
Oxygen saturation
Rodmell, Paul Irvin
A novel oximeter
title A novel oximeter
title_full A novel oximeter
title_fullStr A novel oximeter
title_full_unstemmed A novel oximeter
title_short A novel oximeter
title_sort novel oximeter
topic Oximetry
Oxygen saturation
url https://eprints.nottingham.ac.uk/31151/