EPI at 7T : functional imaging and off-resonance correction techniques

The work presented in this thesis describes the development and implementation of a number of ideas and methods that allow fMRI to be carried out using echo-planar imaging at ultra high field strength, despite the significant problems associated with this. In the first study, EPI is used to probe h...

Full description

Bibliographic Details
Main Author: Harmer, Jack
Format: Thesis (University of Nottingham only)
Language:English
Published: 2013
Online Access:https://eprints.nottingham.ac.uk/28018/
_version_ 1848793488939810816
author Harmer, Jack
author_facet Harmer, Jack
author_sort Harmer, Jack
building Nottingham Research Data Repository
collection Online Access
description The work presented in this thesis describes the development and implementation of a number of ideas and methods that allow fMRI to be carried out using echo-planar imaging at ultra high field strength, despite the significant problems associated with this. In the first study, EPI is used to probe how the gradient echo (GE) and spin echo (SE) BOLD responses relate to the underlying neurological processes, whilst the brain is in both its active and resting states. These finding show that SE BOLD contrast is harder to detect but less localised to areas around large draining veins than GE BOLD contrast and thus potentially more localised to sites that represent true functional areas of activation. The second study describes how dynamic delta B0 mapping can be performed during fMRI experiments with a hyperoxic challenge in order to assess the magnitude and extent of delta B0 effects that arise due to susceptibility differences between air and tissue. Developing on this, this work describes the steps involved in the design and implementation of a dual echo GE/SE EPI sequence and how it can be used to enable off-resonance effects, such as image distortion and signal concentration/dilution, to be corrected on a dynamic basis for, simultaneously acquired, GE and SE data. The final study demonstrates how such a sequence can be used to detect resting state networks. Showing that the correspondingly low temporal separation of the GE and SE data allows GE and SE BOLD contrast mechanisms to be compared in a number of novels ways in different resting state networks.
first_indexed 2025-11-14T19:01:06Z
format Thesis (University of Nottingham only)
id nottingham-28018
institution University of Nottingham Malaysia Campus
institution_category Local University
language English
last_indexed 2025-11-14T19:01:06Z
publishDate 2013
recordtype eprints
repository_type Digital Repository
spelling nottingham-280182025-02-28T11:32:56Z https://eprints.nottingham.ac.uk/28018/ EPI at 7T : functional imaging and off-resonance correction techniques Harmer, Jack The work presented in this thesis describes the development and implementation of a number of ideas and methods that allow fMRI to be carried out using echo-planar imaging at ultra high field strength, despite the significant problems associated with this. In the first study, EPI is used to probe how the gradient echo (GE) and spin echo (SE) BOLD responses relate to the underlying neurological processes, whilst the brain is in both its active and resting states. These finding show that SE BOLD contrast is harder to detect but less localised to areas around large draining veins than GE BOLD contrast and thus potentially more localised to sites that represent true functional areas of activation. The second study describes how dynamic delta B0 mapping can be performed during fMRI experiments with a hyperoxic challenge in order to assess the magnitude and extent of delta B0 effects that arise due to susceptibility differences between air and tissue. Developing on this, this work describes the steps involved in the design and implementation of a dual echo GE/SE EPI sequence and how it can be used to enable off-resonance effects, such as image distortion and signal concentration/dilution, to be corrected on a dynamic basis for, simultaneously acquired, GE and SE data. The final study demonstrates how such a sequence can be used to detect resting state networks. Showing that the correspondingly low temporal separation of the GE and SE data allows GE and SE BOLD contrast mechanisms to be compared in a number of novels ways in different resting state networks. 2013-07-15 Thesis (University of Nottingham only) NonPeerReviewed application/pdf en arr https://eprints.nottingham.ac.uk/28018/1/602722.pdf Harmer, Jack (2013) EPI at 7T : functional imaging and off-resonance correction techniques. PhD thesis, University of Nottingham.
spellingShingle Harmer, Jack
EPI at 7T : functional imaging and off-resonance correction techniques
title EPI at 7T : functional imaging and off-resonance correction techniques
title_full EPI at 7T : functional imaging and off-resonance correction techniques
title_fullStr EPI at 7T : functional imaging and off-resonance correction techniques
title_full_unstemmed EPI at 7T : functional imaging and off-resonance correction techniques
title_short EPI at 7T : functional imaging and off-resonance correction techniques
title_sort epi at 7t : functional imaging and off-resonance correction techniques
url https://eprints.nottingham.ac.uk/28018/