Reliability and identification of aortic valve prolapse in the horse

Background The objectives were to determine and assess the reliability of criteria for identification of aortic valve prolapse (AVP) using echocardiography in the horse. Results Opinion of equine cardiologists indicated that a long-axis view of the aortic valve (AoV) was most commonly used for...

Full description

Bibliographic Details
Main Authors: Hallowell, Gayle D., Bowen, Mark
Format: Article
Published: BioMed Central 2013
Online Access:https://eprints.nottingham.ac.uk/2378/
_version_ 1848790769407623168
author Hallowell, Gayle D.
Bowen, Mark
author_facet Hallowell, Gayle D.
Bowen, Mark
author_sort Hallowell, Gayle D.
building Nottingham Research Data Repository
collection Online Access
description Background The objectives were to determine and assess the reliability of criteria for identification of aortic valve prolapse (AVP) using echocardiography in the horse. Results Opinion of equine cardiologists indicated that a long-axis view of the aortic valve (AoV) was most commonly used for identification of AVP (46%; n=13). There was consensus that AVP could be mimicked by ultrasound probe malignment. This was confirmed in 7 healthy horses, where the appearance of AVP could be induced by malalignment. In a study of a further 8 healthy horses (5 with AVP) examined daily for 5 days, by two echocardiographers standardized imaging guidelines gave good to excellent agreement for the assessment of AVP (kappa>0.80) and good agreement between days and observers (kappa >0.6). The technique allowed for assessment of the degree of prolapse and measurement of the prolapse distance that provided excellent agreement between echocardiographers, days and observers (kappa/ICC>0.8). Assessments made using real-time zoomed images provided similar measurements to the standard views (ICC=0.9), with agreement for the identification of AVP (kappa>0.8). Short axis views of the AoV were used for identification of AVP by fewer respondents (23%), however provided less agreement for the identification of AVP (kappa>0.6) and only adequate agreement with observations made in long axis (kappa>0.5), with AVP being identified more often in short axis (92%) compared to long axis (76%). Orthogonal views were used by 31% of respondents to identify the presence of AVP, and 85% to identify cusp. Its identification on both views on 4 days was used to categorise horses as having AVP, providing a positive predictive value of 79% and negative predictive value of 18%. Only the non-coronary cusp (NCC) of the AoV was observed to prolapse in these studies. Prolapse of the NCC was confirmed during the optimisation study using four-dimensional echocardiography, which concurred with the findings of two-dimensional echocardiography. Conclusions This study has demonstrated reliable diagnostic criteria for the identification and assessment of AVP that can be used for longitudinal research studies to better define the prevalence and natural history of this condition.
first_indexed 2025-11-14T18:17:53Z
format Article
id nottingham-2378
institution University of Nottingham Malaysia Campus
institution_category Local University
last_indexed 2025-11-14T18:17:53Z
publishDate 2013
publisher BioMed Central
recordtype eprints
repository_type Digital Repository
spelling nottingham-23782020-05-04T16:35:32Z https://eprints.nottingham.ac.uk/2378/ Reliability and identification of aortic valve prolapse in the horse Hallowell, Gayle D. Bowen, Mark Background The objectives were to determine and assess the reliability of criteria for identification of aortic valve prolapse (AVP) using echocardiography in the horse. Results Opinion of equine cardiologists indicated that a long-axis view of the aortic valve (AoV) was most commonly used for identification of AVP (46%; n=13). There was consensus that AVP could be mimicked by ultrasound probe malignment. This was confirmed in 7 healthy horses, where the appearance of AVP could be induced by malalignment. In a study of a further 8 healthy horses (5 with AVP) examined daily for 5 days, by two echocardiographers standardized imaging guidelines gave good to excellent agreement for the assessment of AVP (kappa>0.80) and good agreement between days and observers (kappa >0.6). The technique allowed for assessment of the degree of prolapse and measurement of the prolapse distance that provided excellent agreement between echocardiographers, days and observers (kappa/ICC>0.8). Assessments made using real-time zoomed images provided similar measurements to the standard views (ICC=0.9), with agreement for the identification of AVP (kappa>0.8). Short axis views of the AoV were used for identification of AVP by fewer respondents (23%), however provided less agreement for the identification of AVP (kappa>0.6) and only adequate agreement with observations made in long axis (kappa>0.5), with AVP being identified more often in short axis (92%) compared to long axis (76%). Orthogonal views were used by 31% of respondents to identify the presence of AVP, and 85% to identify cusp. Its identification on both views on 4 days was used to categorise horses as having AVP, providing a positive predictive value of 79% and negative predictive value of 18%. Only the non-coronary cusp (NCC) of the AoV was observed to prolapse in these studies. Prolapse of the NCC was confirmed during the optimisation study using four-dimensional echocardiography, which concurred with the findings of two-dimensional echocardiography. Conclusions This study has demonstrated reliable diagnostic criteria for the identification and assessment of AVP that can be used for longitudinal research studies to better define the prevalence and natural history of this condition. BioMed Central 2013-01-11 Article PeerReviewed Hallowell, Gayle D. and Bowen, Mark (2013) Reliability and identification of aortic valve prolapse in the horse. BMC Veterinary Research, 9 . 9/1-9/9. ISSN 1746-6148 http://www.biomedcentral.com/1746-6148/9/9 doi:10.1186/1746-6148-9-9 doi:10.1186/1746-6148-9-9
spellingShingle Hallowell, Gayle D.
Bowen, Mark
Reliability and identification of aortic valve prolapse in the horse
title Reliability and identification of aortic valve prolapse in the horse
title_full Reliability and identification of aortic valve prolapse in the horse
title_fullStr Reliability and identification of aortic valve prolapse in the horse
title_full_unstemmed Reliability and identification of aortic valve prolapse in the horse
title_short Reliability and identification of aortic valve prolapse in the horse
title_sort reliability and identification of aortic valve prolapse in the horse
url https://eprints.nottingham.ac.uk/2378/
https://eprints.nottingham.ac.uk/2378/
https://eprints.nottingham.ac.uk/2378/