Reducing the gradient artefact in simultaneous EEG-fMRI by adjusting the subject’s axial position

Large artefacts which compromise EEG data quality are generated when electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) are carried out concurrently. The gradient artefact produced by the time-varying magnetic field gradients is the largest of these artefacts. Although ave...

Full description

Bibliographic Details
Main Authors: Mullinger, Karen J., Yan, Winston X., Bowtell, Richard W.
Format: Article
Published: Elsevier 2011
Online Access:https://eprints.nottingham.ac.uk/1453/
_version_ 1848790609514463232
author Mullinger, Karen J.
Yan, Winston X.
Bowtell, Richard W.
author_facet Mullinger, Karen J.
Yan, Winston X.
Bowtell, Richard W.
author_sort Mullinger, Karen J.
building Nottingham Research Data Repository
collection Online Access
description Large artefacts which compromise EEG data quality are generated when electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) are carried out concurrently. The gradient artefact produced by the time-varying magnetic field gradients is the largest of these artefacts. Although average artefact correction (AAS) and related techniques can remove the majority of this artefact, the need to avoid amplifier saturation necessitates the use of a large dynamic range and strong low-pass filtering in EEG recording. Any intrinsic reduction in the gradient artefact amplitude would allow data with a higher bandwidth to be acquired without amplifier saturation, thus increasing the frequency range of neuronal activity that can be investigated using combined EEG-fMRI. Furthermore, gradient artefact correction methods assume a constant artefact morphology over time, so their performance is compromised by subject movement. Since the resulting, residual gradient artefacts can easily swamp signals from brain activity, any reduction in their amplitude would be highly advantageous for simultaneous EEG-fMRI studies. The aim of this work was to investigate whether adjustment of the subject’s axial position in the MRI scanner can reduce the amplitude of the induced gradient artefact, before and after artefact correction using AAS. The variation in gradient artefact amplitude as a function of the subject’s axial position was first investigated in six subjects by applying gradient pulses along the three Cartesian axes. The results of this study showed that a significant reduction in the gradient artefact magnitude can be achieved by shifting the subject axially by 4 cm towards the feet relative to the standard subject position (nasion at iso-centre). In a further study, the 4 cm shift was shown to produce a 40% reduction in the RMS amplitude (and a 31% reduction in the range) of the gradient artefact generated during the execution of a standard multi-slice, EPI sequence. By picking out signals occurring at harmonics of the slice acquisition frequency, it was also shown that the 4 cm shift led to a 36% reduction in the residual gradient artefact after AAS. Functional and anatomical MR data quality is not affected by the 4 cm shift, as the head remains in the homogeneous region of the static magnet field and gradients.
first_indexed 2025-11-14T18:15:20Z
format Article
id nottingham-1453
institution University of Nottingham Malaysia Campus
institution_category Local University
last_indexed 2025-11-14T18:15:20Z
publishDate 2011
publisher Elsevier
recordtype eprints
repository_type Digital Repository
spelling nottingham-14532020-05-04T20:24:24Z https://eprints.nottingham.ac.uk/1453/ Reducing the gradient artefact in simultaneous EEG-fMRI by adjusting the subject’s axial position Mullinger, Karen J. Yan, Winston X. Bowtell, Richard W. Large artefacts which compromise EEG data quality are generated when electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) are carried out concurrently. The gradient artefact produced by the time-varying magnetic field gradients is the largest of these artefacts. Although average artefact correction (AAS) and related techniques can remove the majority of this artefact, the need to avoid amplifier saturation necessitates the use of a large dynamic range and strong low-pass filtering in EEG recording. Any intrinsic reduction in the gradient artefact amplitude would allow data with a higher bandwidth to be acquired without amplifier saturation, thus increasing the frequency range of neuronal activity that can be investigated using combined EEG-fMRI. Furthermore, gradient artefact correction methods assume a constant artefact morphology over time, so their performance is compromised by subject movement. Since the resulting, residual gradient artefacts can easily swamp signals from brain activity, any reduction in their amplitude would be highly advantageous for simultaneous EEG-fMRI studies. The aim of this work was to investigate whether adjustment of the subject’s axial position in the MRI scanner can reduce the amplitude of the induced gradient artefact, before and after artefact correction using AAS. The variation in gradient artefact amplitude as a function of the subject’s axial position was first investigated in six subjects by applying gradient pulses along the three Cartesian axes. The results of this study showed that a significant reduction in the gradient artefact magnitude can be achieved by shifting the subject axially by 4 cm towards the feet relative to the standard subject position (nasion at iso-centre). In a further study, the 4 cm shift was shown to produce a 40% reduction in the RMS amplitude (and a 31% reduction in the range) of the gradient artefact generated during the execution of a standard multi-slice, EPI sequence. By picking out signals occurring at harmonics of the slice acquisition frequency, it was also shown that the 4 cm shift led to a 36% reduction in the residual gradient artefact after AAS. Functional and anatomical MR data quality is not affected by the 4 cm shift, as the head remains in the homogeneous region of the static magnet field and gradients. Elsevier 2011 Article PeerReviewed Mullinger, Karen J., Yan, Winston X. and Bowtell, Richard W. (2011) Reducing the gradient artefact in simultaneous EEG-fMRI by adjusting the subject’s axial position. NeuroImage, 54 (3). pp. 1942-1950. ISSN 1053-8119 http://dx.doi.org/10.1016/j.neuroimage.2010.09.079 doi:10.1016/j.neuroimage.2010.09.079 doi:10.1016/j.neuroimage.2010.09.079
spellingShingle Mullinger, Karen J.
Yan, Winston X.
Bowtell, Richard W.
Reducing the gradient artefact in simultaneous EEG-fMRI by adjusting the subject’s axial position
title Reducing the gradient artefact in simultaneous EEG-fMRI by adjusting the subject’s axial position
title_full Reducing the gradient artefact in simultaneous EEG-fMRI by adjusting the subject’s axial position
title_fullStr Reducing the gradient artefact in simultaneous EEG-fMRI by adjusting the subject’s axial position
title_full_unstemmed Reducing the gradient artefact in simultaneous EEG-fMRI by adjusting the subject’s axial position
title_short Reducing the gradient artefact in simultaneous EEG-fMRI by adjusting the subject’s axial position
title_sort reducing the gradient artefact in simultaneous eeg-fmri by adjusting the subject’s axial position
url https://eprints.nottingham.ac.uk/1453/
https://eprints.nottingham.ac.uk/1453/
https://eprints.nottingham.ac.uk/1453/