Solar facades for heating and cooling in buildings

The aim of this thesis is to study the energy performance of a building integrated heating and cooling system. The research objectives are to investigate the system operating characters, to develop mathematical models for the heating and cooling systems, to demonstrate the technologies experimentall...

Full description

Bibliographic Details
Main Author: Chan, Hoy-Yen
Format: Thesis (University of Nottingham only)
Language:English
Published: 2011
Subjects:
Online Access:https://eprints.nottingham.ac.uk/12319/
_version_ 1848791476224393216
author Chan, Hoy-Yen
author_facet Chan, Hoy-Yen
author_sort Chan, Hoy-Yen
building Nottingham Research Data Repository
collection Online Access
description The aim of this thesis is to study the energy performance of a building integrated heating and cooling system. The research objectives are to investigate the system operating characters, to develop mathematical models for the heating and cooling systems, to demonstrate the technologies experimentally, to identify the best designs for a combined system and to investigate the cost effectiveness of the system. The main components of the systems are the aluminium plate façade and the building wall behind it, these form a plenum between them and the air is then heated or cooled as it flows through this plenum. Mathematical models were developed based on the energy balance equations and solved by matrix inversion method. These models were then validated with experimental results. The experiments were carried out in the laboratory with a facade area of 2m2. Two designs of facade were tested, i.e. flat and transpired plates. Results showed that the transpired design gave better thermal performance; the system efficiency for the flat plate was only about 30%, whereas it was about 85% for the transpired plate. On the other hand, a cooling system with double plenums was found to be better than a single plenum. Thus, a transpired plate with two plenums was identified as the best design for space heating and cooling. The cooling efficiency was nearly 2.0 even at low solar radiation intensity. A simulation study was carried out by assuming a 40m2 of façade was installed on an office building in London. The yearly energy saving was estimated as 10,877kWh, which is equivalent to 5,874kgCO2/year of emission avoidance. The system is calculated to cost about £70/m2, and for a discount rate of 5% and 30 years of lifetime, the payback period for this system would be less than a years.
first_indexed 2025-11-14T18:29:07Z
format Thesis (University of Nottingham only)
id nottingham-12319
institution University of Nottingham Malaysia Campus
institution_category Local University
language English
last_indexed 2025-11-14T18:29:07Z
publishDate 2011
recordtype eprints
repository_type Digital Repository
spelling nottingham-123192025-02-28T11:18:38Z https://eprints.nottingham.ac.uk/12319/ Solar facades for heating and cooling in buildings Chan, Hoy-Yen The aim of this thesis is to study the energy performance of a building integrated heating and cooling system. The research objectives are to investigate the system operating characters, to develop mathematical models for the heating and cooling systems, to demonstrate the technologies experimentally, to identify the best designs for a combined system and to investigate the cost effectiveness of the system. The main components of the systems are the aluminium plate façade and the building wall behind it, these form a plenum between them and the air is then heated or cooled as it flows through this plenum. Mathematical models were developed based on the energy balance equations and solved by matrix inversion method. These models were then validated with experimental results. The experiments were carried out in the laboratory with a facade area of 2m2. Two designs of facade were tested, i.e. flat and transpired plates. Results showed that the transpired design gave better thermal performance; the system efficiency for the flat plate was only about 30%, whereas it was about 85% for the transpired plate. On the other hand, a cooling system with double plenums was found to be better than a single plenum. Thus, a transpired plate with two plenums was identified as the best design for space heating and cooling. The cooling efficiency was nearly 2.0 even at low solar radiation intensity. A simulation study was carried out by assuming a 40m2 of façade was installed on an office building in London. The yearly energy saving was estimated as 10,877kWh, which is equivalent to 5,874kgCO2/year of emission avoidance. The system is calculated to cost about £70/m2, and for a discount rate of 5% and 30 years of lifetime, the payback period for this system would be less than a years. 2011-12-16 Thesis (University of Nottingham only) NonPeerReviewed application/pdf en arr https://eprints.nottingham.ac.uk/12319/1/Final_011111.pdf Chan, Hoy-Yen (2011) Solar facades for heating and cooling in buildings. PhD thesis, University of Nottingham. solar facades heating cooling architecture energy conservation
spellingShingle solar facades
heating
cooling
architecture
energy conservation
Chan, Hoy-Yen
Solar facades for heating and cooling in buildings
title Solar facades for heating and cooling in buildings
title_full Solar facades for heating and cooling in buildings
title_fullStr Solar facades for heating and cooling in buildings
title_full_unstemmed Solar facades for heating and cooling in buildings
title_short Solar facades for heating and cooling in buildings
title_sort solar facades for heating and cooling in buildings
topic solar facades
heating
cooling
architecture
energy conservation
url https://eprints.nottingham.ac.uk/12319/