Sensorless control of AC machines for low and zero speed operation without additional test signal injection

This work considers the sensorless control of AC machines for the low and zero speed operation range. Two novel techniques have been developed that use the inherit nature of the inverter PWM to estimate the rotor position of the machine. The inherent back EMF and the saliency of AC machines can be...

Full description

Bibliographic Details
Main Author: Raute, Reiko
Format: Thesis (University of Nottingham only)
Language:English
Published: 2009
Subjects:
Online Access:https://eprints.nottingham.ac.uk/10930/
_version_ 1848791157397520384
author Raute, Reiko
author_facet Raute, Reiko
author_sort Raute, Reiko
building Nottingham Research Data Repository
collection Online Access
description This work considers the sensorless control of AC machines for the low and zero speed operation range. Two novel techniques have been developed that use the inherit nature of the inverter PWM to estimate the rotor position of the machine. The inherent back EMF and the saliency of AC machines can be utilized to identify the rotor/flux position. The zero vector current derivative (ZVCD) technique for permanent magnet synchronous machines (PMSM) utilizes both of these effects. No additional test signals are injected into the machine and the difficulty in sensing the machine terminal voltage at low speed is eased. Only three standard current transducers are used in the drive system. For the position/ speed estimator only the machine current derivative during the relatively long (at low speed) zero voltage vectors is used for obtaining the rotor position. Practical results show the operation of the drive at several torque and speed conditions including stand still. A further method has been developed for the sensorless control of induction machines. The high frequency harmonics present in a PWM inverter drive system can be used to detect an equivalent impendence saliency that shows modulation due to rotor/ flux position saliency. The proposed method focuses particularly on the extraction of spatial saliency modulation due to rotor bar slotting effect, which can be used to determine the mechanical rotor position. No additional signal injection is required; the method simply employs some of the inherent PWM carrier harmonics.
first_indexed 2025-11-14T18:24:03Z
format Thesis (University of Nottingham only)
id nottingham-10930
institution University of Nottingham Malaysia Campus
institution_category Local University
language English
last_indexed 2025-11-14T18:24:03Z
publishDate 2009
recordtype eprints
repository_type Digital Repository
spelling nottingham-109302025-02-28T11:10:20Z https://eprints.nottingham.ac.uk/10930/ Sensorless control of AC machines for low and zero speed operation without additional test signal injection Raute, Reiko This work considers the sensorless control of AC machines for the low and zero speed operation range. Two novel techniques have been developed that use the inherit nature of the inverter PWM to estimate the rotor position of the machine. The inherent back EMF and the saliency of AC machines can be utilized to identify the rotor/flux position. The zero vector current derivative (ZVCD) technique for permanent magnet synchronous machines (PMSM) utilizes both of these effects. No additional test signals are injected into the machine and the difficulty in sensing the machine terminal voltage at low speed is eased. Only three standard current transducers are used in the drive system. For the position/ speed estimator only the machine current derivative during the relatively long (at low speed) zero voltage vectors is used for obtaining the rotor position. Practical results show the operation of the drive at several torque and speed conditions including stand still. A further method has been developed for the sensorless control of induction machines. The high frequency harmonics present in a PWM inverter drive system can be used to detect an equivalent impendence saliency that shows modulation due to rotor/ flux position saliency. The proposed method focuses particularly on the extraction of spatial saliency modulation due to rotor bar slotting effect, which can be used to determine the mechanical rotor position. No additional signal injection is required; the method simply employs some of the inherent PWM carrier harmonics. 2009-12-10 Thesis (University of Nottingham only) NonPeerReviewed application/pdf en arr https://eprints.nottingham.ac.uk/10930/1/PhDThesis_ReikoRaute.pdf Raute, Reiko (2009) Sensorless control of AC machines for low and zero speed operation without additional test signal injection. PhD thesis, University of Nottingham. Sensorless control AC machines Inverter
spellingShingle Sensorless control
AC machines
Inverter
Raute, Reiko
Sensorless control of AC machines for low and zero speed operation without additional test signal injection
title Sensorless control of AC machines for low and zero speed operation without additional test signal injection
title_full Sensorless control of AC machines for low and zero speed operation without additional test signal injection
title_fullStr Sensorless control of AC machines for low and zero speed operation without additional test signal injection
title_full_unstemmed Sensorless control of AC machines for low and zero speed operation without additional test signal injection
title_short Sensorless control of AC machines for low and zero speed operation without additional test signal injection
title_sort sensorless control of ac machines for low and zero speed operation without additional test signal injection
topic Sensorless control
AC machines
Inverter
url https://eprints.nottingham.ac.uk/10930/