The detection and measurement of hydrogen sulphide

Gas measurement techniques for hydrogen sulphide (H2S) have been investigated, with particular reference to the monitoring of average ambient concentrations and also the rapidly changing concentrations which may be associated with vehicle pollution. Two new techniques have been identified, and new...

Full description

Bibliographic Details
Main Author: Deuchar, Christopher Norton
Format: Thesis (University of Nottingham only)
Language:English
Published: 2003
Subjects:
Online Access:https://eprints.nottingham.ac.uk/10223/
_version_ 1848791049679405056
author Deuchar, Christopher Norton
author_facet Deuchar, Christopher Norton
author_sort Deuchar, Christopher Norton
building Nottingham Research Data Repository
collection Online Access
description Gas measurement techniques for hydrogen sulphide (H2S) have been investigated, with particular reference to the monitoring of average ambient concentrations and also the rapidly changing concentrations which may be associated with vehicle pollution. Two new techniques have been identified, and new equipment built and tested, for H2S determination. The first of these is designed to measure long term average concentrations of H2S and the second to evaluate rapidly changing peak concentrations over very short periods of time. The implementation of catalytic converters in modern petrol driven motor vehicles has resulted in undesirable emissions of hydrogen sulphide gas. The reasons for these emissions are discussed. Ambient concentrations of H2S have been measured at the roadside and the average contribution originating from vehicular emissions on major roads determined. Results are presented which confirm the elevation of hydrogen sulphide concentrations at the road side of an average of single figure parts per billion. Peak H2S concentrations of up to 100 ppb were also measured at the roadside and within motor vehicles. The peaks were of very short duration and therefore of only minimal contribution to average ambient concentrations. Measurements of H2S concentrations at a variety of locations have also been made,and results are presented, of comparisons between areas with no source of H2S nearby, roadside sites and other possible H2S sources such as sewage treatment works and landfill sites. Known H2S concentrations, in excess of 500 ppm from a point source on a landfill site, were found to diminish rapidly toward zero, within 150 m of the source. This demonstrated the high reactivity of H2S and therefore the importance of measuring H2S concentration as closely as possible to the emission source. Consequently, this high reactivity is particularly important in the consideration of roadside and 'on-road' monitoring of H2S.
first_indexed 2025-11-14T18:22:20Z
format Thesis (University of Nottingham only)
id nottingham-10223
institution University of Nottingham Malaysia Campus
institution_category Local University
language English
last_indexed 2025-11-14T18:22:20Z
publishDate 2003
recordtype eprints
repository_type Digital Repository
spelling nottingham-102232025-02-28T11:07:31Z https://eprints.nottingham.ac.uk/10223/ The detection and measurement of hydrogen sulphide Deuchar, Christopher Norton Gas measurement techniques for hydrogen sulphide (H2S) have been investigated, with particular reference to the monitoring of average ambient concentrations and also the rapidly changing concentrations which may be associated with vehicle pollution. Two new techniques have been identified, and new equipment built and tested, for H2S determination. The first of these is designed to measure long term average concentrations of H2S and the second to evaluate rapidly changing peak concentrations over very short periods of time. The implementation of catalytic converters in modern petrol driven motor vehicles has resulted in undesirable emissions of hydrogen sulphide gas. The reasons for these emissions are discussed. Ambient concentrations of H2S have been measured at the roadside and the average contribution originating from vehicular emissions on major roads determined. Results are presented which confirm the elevation of hydrogen sulphide concentrations at the road side of an average of single figure parts per billion. Peak H2S concentrations of up to 100 ppb were also measured at the roadside and within motor vehicles. The peaks were of very short duration and therefore of only minimal contribution to average ambient concentrations. Measurements of H2S concentrations at a variety of locations have also been made,and results are presented, of comparisons between areas with no source of H2S nearby, roadside sites and other possible H2S sources such as sewage treatment works and landfill sites. Known H2S concentrations, in excess of 500 ppm from a point source on a landfill site, were found to diminish rapidly toward zero, within 150 m of the source. This demonstrated the high reactivity of H2S and therefore the importance of measuring H2S concentration as closely as possible to the emission source. Consequently, this high reactivity is particularly important in the consideration of roadside and 'on-road' monitoring of H2S. 2003 Thesis (University of Nottingham only) NonPeerReviewed application/pdf en arr https://eprints.nottingham.ac.uk/10223/1/ThesisDeuchar2003.pdf Deuchar, Christopher Norton (2003) The detection and measurement of hydrogen sulphide. PhD thesis, University of Nottingham. Hydrogen suplhide hydrogen sulfide H2S ambient motor vehicles landfill roadside catalytic converter sewage
spellingShingle Hydrogen suplhide
hydrogen sulfide
H2S
ambient
motor vehicles
landfill
roadside
catalytic converter
sewage
Deuchar, Christopher Norton
The detection and measurement of hydrogen sulphide
title The detection and measurement of hydrogen sulphide
title_full The detection and measurement of hydrogen sulphide
title_fullStr The detection and measurement of hydrogen sulphide
title_full_unstemmed The detection and measurement of hydrogen sulphide
title_short The detection and measurement of hydrogen sulphide
title_sort detection and measurement of hydrogen sulphide
topic Hydrogen suplhide
hydrogen sulfide
H2S
ambient
motor vehicles
landfill
roadside
catalytic converter
sewage
url https://eprints.nottingham.ac.uk/10223/