In situ determination of the static inductance and resistance of a plasma focus capacitor bank

The static (unloaded) electrical parameters of a capacitor bank are of utmost importance for the purpose of modeling the system as a whole when the capacitor bank is discharged into its dynamic electromagnetic load. Using a physical short circuit across the electromagnetic load is usually technic...

Full description

Bibliographic Details
Main Authors: Saw, S. H., Lee, S., Roy, F., Chong, P. L., Vengadeswaran, V., Sidik, A. S. M., Leong, Y. W., Arwinder, Singh*
Format: Article
Language:English
Published: AIP Publishing 2010
Subjects:
Online Access:http://eprints.intimal.edu.my/265/
http://eprints.intimal.edu.my/265/1/1.pdf
_version_ 1848766434151235584
author Saw, S. H.
Lee, S.
Roy, F.
Chong, P. L.
Vengadeswaran, V.
Sidik, A. S. M.
Leong, Y. W.
Arwinder, Singh*
author_facet Saw, S. H.
Lee, S.
Roy, F.
Chong, P. L.
Vengadeswaran, V.
Sidik, A. S. M.
Leong, Y. W.
Arwinder, Singh*
author_sort Saw, S. H.
building INTI Institutional Repository
collection Online Access
description The static (unloaded) electrical parameters of a capacitor bank are of utmost importance for the purpose of modeling the system as a whole when the capacitor bank is discharged into its dynamic electromagnetic load. Using a physical short circuit across the electromagnetic load is usually technically difficult and is unnecessary. The discharge can be operated at the highest pressure permissible in order to minimize current sheet motion, thus simulating zero dynamic load, to enable bank parameters, static inductance L0, and resistance r0 to be obtained using lightly damped sinusoid equations given the bank capacitance C0. However, for a plasma focus, even at the highest permissible pressure it is found that there is significant residual motion, so that the assumption of a zero dynamic load introduces unacceptable errors into the determination of the circuit parameters. To overcome this problem, the Lee model code is used to fit the computed current trace to the measured current waveform. Hence the dynamics is incorporated into the solution and the capacitor bank parameters are computed using the Lee model code, and more accurate static bank parameters are obtained.
first_indexed 2025-11-14T11:51:05Z
format Article
id intimal-265
institution INTI International University
institution_category Local University
language English
last_indexed 2025-11-14T11:51:05Z
publishDate 2010
publisher AIP Publishing
recordtype eprints
repository_type Digital Repository
spelling intimal-2652017-11-22T07:12:18Z http://eprints.intimal.edu.my/265/ In situ determination of the static inductance and resistance of a plasma focus capacitor bank Saw, S. H. Lee, S. Roy, F. Chong, P. L. Vengadeswaran, V. Sidik, A. S. M. Leong, Y. W. Arwinder, Singh* QC Physics The static (unloaded) electrical parameters of a capacitor bank are of utmost importance for the purpose of modeling the system as a whole when the capacitor bank is discharged into its dynamic electromagnetic load. Using a physical short circuit across the electromagnetic load is usually technically difficult and is unnecessary. The discharge can be operated at the highest pressure permissible in order to minimize current sheet motion, thus simulating zero dynamic load, to enable bank parameters, static inductance L0, and resistance r0 to be obtained using lightly damped sinusoid equations given the bank capacitance C0. However, for a plasma focus, even at the highest permissible pressure it is found that there is significant residual motion, so that the assumption of a zero dynamic load introduces unacceptable errors into the determination of the circuit parameters. To overcome this problem, the Lee model code is used to fit the computed current trace to the measured current waveform. Hence the dynamics is incorporated into the solution and the capacitor bank parameters are computed using the Lee model code, and more accurate static bank parameters are obtained. AIP Publishing 2010 Article PeerReviewed text en http://eprints.intimal.edu.my/265/1/1.pdf Saw, S. H. and Lee, S. and Roy, F. and Chong, P. L. and Vengadeswaran, V. and Sidik, A. S. M. and Leong, Y. W. and Arwinder, Singh* (2010) In situ determination of the static inductance and resistance of a plasma focus capacitor bank. Review of Scientific Instruments, 81 (5). ISSN 1089-7623 10.1063/1.3429207
spellingShingle QC Physics
Saw, S. H.
Lee, S.
Roy, F.
Chong, P. L.
Vengadeswaran, V.
Sidik, A. S. M.
Leong, Y. W.
Arwinder, Singh*
In situ determination of the static inductance and resistance of a plasma focus capacitor bank
title In situ determination of the static inductance and resistance of a plasma focus capacitor bank
title_full In situ determination of the static inductance and resistance of a plasma focus capacitor bank
title_fullStr In situ determination of the static inductance and resistance of a plasma focus capacitor bank
title_full_unstemmed In situ determination of the static inductance and resistance of a plasma focus capacitor bank
title_short In situ determination of the static inductance and resistance of a plasma focus capacitor bank
title_sort in situ determination of the static inductance and resistance of a plasma focus capacitor bank
topic QC Physics
url http://eprints.intimal.edu.my/265/
http://eprints.intimal.edu.my/265/
http://eprints.intimal.edu.my/265/1/1.pdf