A study on relative humidity sensors using PVA and PMMA coating

Simple relative humidity sensors are demonstrated using tapered silica microfibers. The silica microfibers are tapered using flame brushing method to reduce the fiber's waist diameter from 128 micrometers to 2.6 micrometers. The tapered silica microfibers were then coated using polyvinyl acetat...

Full description

Bibliographic Details
Main Authors: Zuraidah*, Harith, Huda Adnan, Abdullah Zain, Malathy, Batumalay, Sulaiman Wadi, Harun
Format: Article
Published: IOP Publishing Ltd 2019
Subjects:
Online Access:http://eprints.intimal.edu.my/1367/
Description
Summary:Simple relative humidity sensors are demonstrated using tapered silica microfibers. The silica microfibers are tapered using flame brushing method to reduce the fiber's waist diameter from 128 micrometers to 2.6 micrometers. The tapered silica microfibers were then coated using polyvinyl acetate (PVA) and polymethyl methacrylate (PMMA) before it was used to sense the relative humidity. The tapered silica microfiber coated with PVA performed better compared to tapered silica microfiber coated using PMMA. The tapered silica microfiber with PVA based sensor has better sensitivity of 0.3023 dB/RH%.