The Evaluation of Design Guidelines for Stratum Ventilation in the Tropics

Building ventilation is highly used and rated at one of the highest energy consuming categories. Numerous efforts have been done to reduce energy usage and thus the evolution of green buildings. However, the conventional design has generated plenty comfort and health related issues. Stratum ventilat...

Full description

Bibliographic Details
Main Author: Liew, Hui Jin
Format: Thesis
Language:English
Published: 2015
Subjects:
Online Access:http://eprints.intimal.edu.my/106/
http://eprints.intimal.edu.my/106/1/BMEGI%20-%2047.pdf
_version_ 1848766372064002048
author Liew, Hui Jin
author_facet Liew, Hui Jin
author_sort Liew, Hui Jin
building INTI Institutional Repository
collection Online Access
description Building ventilation is highly used and rated at one of the highest energy consuming categories. Numerous efforts have been done to reduce energy usage and thus the evolution of green buildings. However, the conventional design has generated plenty comfort and health related issues. Stratum ventilation has been studied from 2009 and the potential of the design for thermal corn tort is regarded as good compared to existing designs like the ceiling-based or the under-floor design. INTl International University takes part as study field for simulation model to evaluate stratum ventilation for airflow patterns, velocity profile, temperature, relative humidity and also local mean age. A small room (W4m x L5.15m) and a medium size room (W7.85m x L9.2m) has been modelled and simulated with FIoEFD software to understand the stratum potential. Prior to that, the flow of air and velocity of air has been determined using design guidelines and standards that limit the design of stratum ventilation. The overall result of the models is acceptable as the thermal comfort when evaluated using the Fanger’s Model of PMV-PPD Model. Occupant’s breathing zone is evaluated and PMV Index based on ASIIRAE Thermal Comfort Tool has shown majority of the occupants are within the cool region between -0.3 up to-l.3. The local mean age of air for medium size room is ranging from 250s to 300s while small room from 60s to 120s. According to the results, the thermal comfort using stratum ventilation in a tropical country is acceptable.�
first_indexed 2025-11-14T11:50:06Z
format Thesis
id intimal-106
institution INTI International University
institution_category Local University
language English
last_indexed 2025-11-14T11:50:06Z
publishDate 2015
recordtype eprints
repository_type Digital Repository
spelling intimal-1062016-04-06T09:45:59Z http://eprints.intimal.edu.my/106/ The Evaluation of Design Guidelines for Stratum Ventilation in the Tropics Liew, Hui Jin TJ Mechanical engineering and machinery Building ventilation is highly used and rated at one of the highest energy consuming categories. Numerous efforts have been done to reduce energy usage and thus the evolution of green buildings. However, the conventional design has generated plenty comfort and health related issues. Stratum ventilation has been studied from 2009 and the potential of the design for thermal corn tort is regarded as good compared to existing designs like the ceiling-based or the under-floor design. INTl International University takes part as study field for simulation model to evaluate stratum ventilation for airflow patterns, velocity profile, temperature, relative humidity and also local mean age. A small room (W4m x L5.15m) and a medium size room (W7.85m x L9.2m) has been modelled and simulated with FIoEFD software to understand the stratum potential. Prior to that, the flow of air and velocity of air has been determined using design guidelines and standards that limit the design of stratum ventilation. The overall result of the models is acceptable as the thermal comfort when evaluated using the Fanger’s Model of PMV-PPD Model. Occupant’s breathing zone is evaluated and PMV Index based on ASIIRAE Thermal Comfort Tool has shown majority of the occupants are within the cool region between -0.3 up to-l.3. The local mean age of air for medium size room is ranging from 250s to 300s while small room from 60s to 120s. According to the results, the thermal comfort using stratum ventilation in a tropical country is acceptable.� 2015 Thesis NonPeerReviewed text en http://eprints.intimal.edu.my/106/1/BMEGI%20-%2047.pdf Liew, Hui Jin (2015) The Evaluation of Design Guidelines for Stratum Ventilation in the Tropics. Other thesis, INTI International University.
spellingShingle TJ Mechanical engineering and machinery
Liew, Hui Jin
The Evaluation of Design Guidelines for Stratum Ventilation in the Tropics
title The Evaluation of Design Guidelines for Stratum Ventilation in the Tropics
title_full The Evaluation of Design Guidelines for Stratum Ventilation in the Tropics
title_fullStr The Evaluation of Design Guidelines for Stratum Ventilation in the Tropics
title_full_unstemmed The Evaluation of Design Guidelines for Stratum Ventilation in the Tropics
title_short The Evaluation of Design Guidelines for Stratum Ventilation in the Tropics
title_sort evaluation of design guidelines for stratum ventilation in the tropics
topic TJ Mechanical engineering and machinery
url http://eprints.intimal.edu.my/106/
http://eprints.intimal.edu.my/106/1/BMEGI%20-%2047.pdf