Fracture prediction on patient-specific tibia model with osteogenesis Imperfecta under various loading direction

This study aims to predict the fracture of bone with osteogenesis imperfecta (OI) by considering the homogenization properties of real patient. A Type-III of osteotomy in OI femur was used as bone specimen. Nine representative volume element (RVE) models were developed based on μCT-images of bone...

Full description

Bibliographic Details
Main Authors: Mok, C J, Basaruddin, Khairul Salleh, Mat Som, Mohd Hanafi, A. Majid, M.S.A., Sulaiman, Abdul Razak, Awang, Mohd Shukrimi
Format: Proceeding Paper
Language:English
English
Published: Institute of Physics Publishing 2019
Subjects:
Online Access:http://irep.iium.edu.my/79664/
http://irep.iium.edu.my/79664/1/79664_Fracture%20prediction%20on%20patient-specific_conf.%20article.pdf
http://irep.iium.edu.my/79664/2/79664_Fracture%20prediction%20on%20patient-specific_scopus.pdf
_version_ 1848788812934676480
author Mok, C J
Basaruddin, Khairul Salleh
Mat Som, Mohd Hanafi
A. Majid, M.S.A.
Sulaiman, Abdul Razak
Awang, Mohd Shukrimi
author_facet Mok, C J
Basaruddin, Khairul Salleh
Mat Som, Mohd Hanafi
A. Majid, M.S.A.
Sulaiman, Abdul Razak
Awang, Mohd Shukrimi
author_sort Mok, C J
building IIUM Repository
collection Online Access
description This study aims to predict the fracture of bone with osteogenesis imperfecta (OI) by considering the homogenization properties of real patient. A Type-III of osteotomy in OI femur was used as bone specimen. Nine representative volume element (RVE) models were developed based on μCT-images of bone specimen. Homogenized properties particularly the Young's moduli of the RVEs was obtained based on homogenization theory in Voxelcon software. The obtained homogenized properties were then assigned to the OI patient-specific model that was developed from CT-images of real patient. The fracture of OI bone was predicted based on linear static analysis and finite element method under loadings of activity daily living (ADL). The results found that the fracture might be happen to the patient under jumping load case, whereas the subject is expected to be safe under standing still and walking load case.
first_indexed 2025-11-14T17:46:47Z
format Proceeding Paper
id iium-79664
institution International Islamic University Malaysia
institution_category Local University
language English
English
last_indexed 2025-11-14T17:46:47Z
publishDate 2019
publisher Institute of Physics Publishing
recordtype eprints
repository_type Digital Repository
spelling iium-796642021-02-01T00:47:18Z http://irep.iium.edu.my/79664/ Fracture prediction on patient-specific tibia model with osteogenesis Imperfecta under various loading direction Mok, C J Basaruddin, Khairul Salleh Mat Som, Mohd Hanafi A. Majid, M.S.A. Sulaiman, Abdul Razak Awang, Mohd Shukrimi R Medicine (General) RD701 Orthopedics TJ Mechanical engineering and machinery This study aims to predict the fracture of bone with osteogenesis imperfecta (OI) by considering the homogenization properties of real patient. A Type-III of osteotomy in OI femur was used as bone specimen. Nine representative volume element (RVE) models were developed based on μCT-images of bone specimen. Homogenized properties particularly the Young's moduli of the RVEs was obtained based on homogenization theory in Voxelcon software. The obtained homogenized properties were then assigned to the OI patient-specific model that was developed from CT-images of real patient. The fracture of OI bone was predicted based on linear static analysis and finite element method under loadings of activity daily living (ADL). The results found that the fracture might be happen to the patient under jumping load case, whereas the subject is expected to be safe under standing still and walking load case. Institute of Physics Publishing 2019-12-02 Proceeding Paper NonPeerReviewed application/pdf en http://irep.iium.edu.my/79664/1/79664_Fracture%20prediction%20on%20patient-specific_conf.%20article.pdf application/pdf en http://irep.iium.edu.my/79664/2/79664_Fracture%20prediction%20on%20patient-specific_scopus.pdf Mok, C J and Basaruddin, Khairul Salleh and Mat Som, Mohd Hanafi and A. Majid, M.S.A. and Sulaiman, Abdul Razak and Awang, Mohd Shukrimi (2019) Fracture prediction on patient-specific tibia model with osteogenesis Imperfecta under various loading direction. In: "6th International Conference on Applications and Design in Mechanical Engineering 2019, ICADME 2019", 26 - 27 August 2019, Penang. https://iopscience.iop.org/article/10.1088/1757-899X/670/1/012073/meta 10.1088/1757-899X/670/1/012073
spellingShingle R Medicine (General)
RD701 Orthopedics
TJ Mechanical engineering and machinery
Mok, C J
Basaruddin, Khairul Salleh
Mat Som, Mohd Hanafi
A. Majid, M.S.A.
Sulaiman, Abdul Razak
Awang, Mohd Shukrimi
Fracture prediction on patient-specific tibia model with osteogenesis Imperfecta under various loading direction
title Fracture prediction on patient-specific tibia model with osteogenesis Imperfecta under various loading direction
title_full Fracture prediction on patient-specific tibia model with osteogenesis Imperfecta under various loading direction
title_fullStr Fracture prediction on patient-specific tibia model with osteogenesis Imperfecta under various loading direction
title_full_unstemmed Fracture prediction on patient-specific tibia model with osteogenesis Imperfecta under various loading direction
title_short Fracture prediction on patient-specific tibia model with osteogenesis Imperfecta under various loading direction
title_sort fracture prediction on patient-specific tibia model with osteogenesis imperfecta under various loading direction
topic R Medicine (General)
RD701 Orthopedics
TJ Mechanical engineering and machinery
url http://irep.iium.edu.my/79664/
http://irep.iium.edu.my/79664/
http://irep.iium.edu.my/79664/
http://irep.iium.edu.my/79664/1/79664_Fracture%20prediction%20on%20patient-specific_conf.%20article.pdf
http://irep.iium.edu.my/79664/2/79664_Fracture%20prediction%20on%20patient-specific_scopus.pdf