Rapid method for determining malondialdehyde as secondary oxidation product in palm olein system by Fourier transform infrared spectroscopy

A simple and rapid Fourier transform infrared (FTIR) spectroscopic method has been developed for the quantitative determination of malondialdehyde as secondary oxidation product in a palm olein system. The FTIR method was based on a sodium chloride transmission cell and utilised a partial least squ...

Full description

Bibliographic Details
Main Authors: Mirghani, Mohamed Elwathig Saeed, Che Man, Yakoob, Selamat, Jinap, Baharin , B. S., Bakar, Jamilah
Format: Article
Language:English
English
Published: http://www.wiley.com/bw/journal.asp?ref=0958-0344 2002
Subjects:
Online Access:http://irep.iium.edu.my/7790/
http://irep.iium.edu.my/7790/1/Phytochemical_Analysis.BMP
http://irep.iium.edu.my/7790/2/Phyrochemical_Analysis.pdf
_version_ 1848776905656893440
author Mirghani, Mohamed Elwathig Saeed
Che Man, Yakoob
Selamat, Jinap
Baharin , B. S.
Bakar, Jamilah
author_facet Mirghani, Mohamed Elwathig Saeed
Che Man, Yakoob
Selamat, Jinap
Baharin , B. S.
Bakar, Jamilah
author_sort Mirghani, Mohamed Elwathig Saeed
building IIUM Repository
collection Online Access
description A simple and rapid Fourier transform infrared (FTIR) spectroscopic method has been developed for the quantitative determination of malondialdehyde as secondary oxidation product in a palm olein system. The FTIR method was based on a sodium chloride transmission cell and utilised a partial least square statistical approach to derive a calibration model. The frequency region combinations that gave good calibration were 2900–2800, and 1800–1600 cm−1. The precision and accuracy, in the range 0–60 µmol malondialdehyde/kg oil, were comparable to those of the modified distillation method with a coefficient of determination (r2) of 0.9891 and standard error of calibration of 1.49. The calibration was cross-validated and produced an r2 of 0.9786 and standard error of prediction of 2.136. The results showed that the FTIR method is versatile, efficient and accurate, and suitable for routine quality control analysis with the result obtainable in about 2 min from a sample of less than 2 mL. Copyright © 2002 John Wiley & Sons, Ltd.
first_indexed 2025-11-14T14:37:31Z
format Article
id iium-7790
institution International Islamic University Malaysia
institution_category Local University
language English
English
last_indexed 2025-11-14T14:37:31Z
publishDate 2002
publisher http://www.wiley.com/bw/journal.asp?ref=0958-0344
recordtype eprints
repository_type Digital Repository
spelling iium-77902012-05-08T00:43:40Z http://irep.iium.edu.my/7790/ Rapid method for determining malondialdehyde as secondary oxidation product in palm olein system by Fourier transform infrared spectroscopy Mirghani, Mohamed Elwathig Saeed Che Man, Yakoob Selamat, Jinap Baharin , B. S. Bakar, Jamilah T Technology (General) A simple and rapid Fourier transform infrared (FTIR) spectroscopic method has been developed for the quantitative determination of malondialdehyde as secondary oxidation product in a palm olein system. The FTIR method was based on a sodium chloride transmission cell and utilised a partial least square statistical approach to derive a calibration model. The frequency region combinations that gave good calibration were 2900–2800, and 1800–1600 cm−1. The precision and accuracy, in the range 0–60 µmol malondialdehyde/kg oil, were comparable to those of the modified distillation method with a coefficient of determination (r2) of 0.9891 and standard error of calibration of 1.49. The calibration was cross-validated and produced an r2 of 0.9786 and standard error of prediction of 2.136. The results showed that the FTIR method is versatile, efficient and accurate, and suitable for routine quality control analysis with the result obtainable in about 2 min from a sample of less than 2 mL. Copyright © 2002 John Wiley & Sons, Ltd. http://www.wiley.com/bw/journal.asp?ref=0958-0344 2002-05-15 Article PeerReviewed application/pdf en http://irep.iium.edu.my/7790/1/Phytochemical_Analysis.BMP application/pdf en http://irep.iium.edu.my/7790/2/Phyrochemical_Analysis.pdf Mirghani, Mohamed Elwathig Saeed and Che Man, Yakoob and Selamat, Jinap and Baharin , B. S. and Bakar, Jamilah (2002) Rapid method for determining malondialdehyde as secondary oxidation product in palm olein system by Fourier transform infrared spectroscopy. Phytochemical Analysis , 13 (4). pp. 195-201. ISSN 1099-1565 http://www.wiley.com/bw/journal.asp?ref=0958-0344 DOI: 10.1002/pca.641
spellingShingle T Technology (General)
Mirghani, Mohamed Elwathig Saeed
Che Man, Yakoob
Selamat, Jinap
Baharin , B. S.
Bakar, Jamilah
Rapid method for determining malondialdehyde as secondary oxidation product in palm olein system by Fourier transform infrared spectroscopy
title Rapid method for determining malondialdehyde as secondary oxidation product in palm olein system by Fourier transform infrared spectroscopy
title_full Rapid method for determining malondialdehyde as secondary oxidation product in palm olein system by Fourier transform infrared spectroscopy
title_fullStr Rapid method for determining malondialdehyde as secondary oxidation product in palm olein system by Fourier transform infrared spectroscopy
title_full_unstemmed Rapid method for determining malondialdehyde as secondary oxidation product in palm olein system by Fourier transform infrared spectroscopy
title_short Rapid method for determining malondialdehyde as secondary oxidation product in palm olein system by Fourier transform infrared spectroscopy
title_sort rapid method for determining malondialdehyde as secondary oxidation product in palm olein system by fourier transform infrared spectroscopy
topic T Technology (General)
url http://irep.iium.edu.my/7790/
http://irep.iium.edu.my/7790/
http://irep.iium.edu.my/7790/
http://irep.iium.edu.my/7790/1/Phytochemical_Analysis.BMP
http://irep.iium.edu.my/7790/2/Phyrochemical_Analysis.pdf