Delay analysis of two-way synchronization scheme for phasor measurement unit based digital smart grid applications

The power system has been experiencing adaptation of new problem solving technologies which have intelligent capabilities to arrive better solutions. Smart Grid is the best leading technology that presents better integration platforms of synchronous power generation system (Solar energy, hydro p...

Full description

Bibliographic Details
Main Authors: Hasan, Mohammad Kamrul, Ahmed, Musse Mohamud, Janin, Zuriati, Khan, Sheroz, Hassan Abdalla Hashim, Aisha, Islam, Shayla
Format: Proceeding Paper
Language:English
English
Published: IEEE 2019
Subjects:
Online Access:http://irep.iium.edu.my/72525/
http://irep.iium.edu.my/72525/1/72525%20Delay%20Analysis%20of%20Two-way%20Synchronization%20Scheme%20SCOPUS.pdf
http://irep.iium.edu.my/72525/2/72525%20Delay%20Analysis%20of%20Two-way%20Synchronization%20Scheme%20for%20Phasor%20Measurement.pdf
_version_ 1848787626332520448
author Hasan, Mohammad Kamrul
Ahmed, Musse Mohamud
Janin, Zuriati
Khan, Sheroz
Hassan Abdalla Hashim, Aisha
Islam, Shayla
author_facet Hasan, Mohammad Kamrul
Ahmed, Musse Mohamud
Janin, Zuriati
Khan, Sheroz
Hassan Abdalla Hashim, Aisha
Islam, Shayla
author_sort Hasan, Mohammad Kamrul
building IIUM Repository
collection Online Access
description The power system has been experiencing adaptation of new problem solving technologies which have intelligent capabilities to arrive better solutions. Smart Grid is the best leading technology that presents better integration platforms of synchronous power generation system (Solar energy, hydro power plant, thermal plant, coal based power plant as well as fuel based power generation systems. Likewise, other power system components that require efficient techniques and methods for solving day-to-day problems have also being applied to the Smart Grid. Thus, the variables and the parameters of electrical and mechanical occurrences are needed to monitor, detect faults, measures the accuracies that actions timely to an interconnected grid system. In WAM-based smart grid system, the occurrences are monitored using frequency parameters, rotational speed as well as phasor angles of voltage. This parameter ensures the fault detection, monitoring, measurement and control of the interconnected digital smart grid applications. The recent development of IEEE C37.118 based frameworks in Phasor Measurement Unit (PMU) based Wide Area Measurement (WAM) systems of smart grid. However due to extensive level of delay and error the grid application became unstable in measuring, controlling and monitoring. Therefore, this paper has designed the two-way synchronization communication framework for smart grid application. The mat lab based simulation evaluation has made to measure the delay occurrences in smart grid applications. The designed scheme is a higher-level communication scheme is to be utilized, and validated to come up with the required solution of reconciling between input values and output values from the available synchronous applications.
first_indexed 2025-11-14T17:27:55Z
format Proceeding Paper
id iium-72525
institution International Islamic University Malaysia
institution_category Local University
language English
English
last_indexed 2025-11-14T17:27:55Z
publishDate 2019
publisher IEEE
recordtype eprints
repository_type Digital Repository
spelling iium-725252020-07-29T07:19:17Z http://irep.iium.edu.my/72525/ Delay analysis of two-way synchronization scheme for phasor measurement unit based digital smart grid applications Hasan, Mohammad Kamrul Ahmed, Musse Mohamud Janin, Zuriati Khan, Sheroz Hassan Abdalla Hashim, Aisha Islam, Shayla T Technology (General) The power system has been experiencing adaptation of new problem solving technologies which have intelligent capabilities to arrive better solutions. Smart Grid is the best leading technology that presents better integration platforms of synchronous power generation system (Solar energy, hydro power plant, thermal plant, coal based power plant as well as fuel based power generation systems. Likewise, other power system components that require efficient techniques and methods for solving day-to-day problems have also being applied to the Smart Grid. Thus, the variables and the parameters of electrical and mechanical occurrences are needed to monitor, detect faults, measures the accuracies that actions timely to an interconnected grid system. In WAM-based smart grid system, the occurrences are monitored using frequency parameters, rotational speed as well as phasor angles of voltage. This parameter ensures the fault detection, monitoring, measurement and control of the interconnected digital smart grid applications. The recent development of IEEE C37.118 based frameworks in Phasor Measurement Unit (PMU) based Wide Area Measurement (WAM) systems of smart grid. However due to extensive level of delay and error the grid application became unstable in measuring, controlling and monitoring. Therefore, this paper has designed the two-way synchronization communication framework for smart grid application. The mat lab based simulation evaluation has made to measure the delay occurrences in smart grid applications. The designed scheme is a higher-level communication scheme is to be utilized, and validated to come up with the required solution of reconciling between input values and output values from the available synchronous applications. IEEE 2019-04-15 Proceeding Paper PeerReviewed application/pdf en http://irep.iium.edu.my/72525/1/72525%20Delay%20Analysis%20of%20Two-way%20Synchronization%20Scheme%20SCOPUS.pdf application/pdf en http://irep.iium.edu.my/72525/2/72525%20Delay%20Analysis%20of%20Two-way%20Synchronization%20Scheme%20for%20Phasor%20Measurement.pdf Hasan, Mohammad Kamrul and Ahmed, Musse Mohamud and Janin, Zuriati and Khan, Sheroz and Hassan Abdalla Hashim, Aisha and Islam, Shayla (2019) Delay analysis of two-way synchronization scheme for phasor measurement unit based digital smart grid applications. In: 2018 IEEE 5th International Conference on Smart Instrumentation, Measurement and Application (ICSIMA), 28th-30th November 2018, Songkla, Thailand. https://ieeexplore-ieee-org.ezproxy.um.edu.my/document/8688788 10.1109/ICSIMA.2018.8688788
spellingShingle T Technology (General)
Hasan, Mohammad Kamrul
Ahmed, Musse Mohamud
Janin, Zuriati
Khan, Sheroz
Hassan Abdalla Hashim, Aisha
Islam, Shayla
Delay analysis of two-way synchronization scheme for phasor measurement unit based digital smart grid applications
title Delay analysis of two-way synchronization scheme for phasor measurement unit based digital smart grid applications
title_full Delay analysis of two-way synchronization scheme for phasor measurement unit based digital smart grid applications
title_fullStr Delay analysis of two-way synchronization scheme for phasor measurement unit based digital smart grid applications
title_full_unstemmed Delay analysis of two-way synchronization scheme for phasor measurement unit based digital smart grid applications
title_short Delay analysis of two-way synchronization scheme for phasor measurement unit based digital smart grid applications
title_sort delay analysis of two-way synchronization scheme for phasor measurement unit based digital smart grid applications
topic T Technology (General)
url http://irep.iium.edu.my/72525/
http://irep.iium.edu.my/72525/
http://irep.iium.edu.my/72525/
http://irep.iium.edu.my/72525/1/72525%20Delay%20Analysis%20of%20Two-way%20Synchronization%20Scheme%20SCOPUS.pdf
http://irep.iium.edu.my/72525/2/72525%20Delay%20Analysis%20of%20Two-way%20Synchronization%20Scheme%20for%20Phasor%20Measurement.pdf