Inter-digital sensor for non-invasive blood glucose monitoring
This paper is to describe a contemporary approach of microwave spectroscopy by adapting the interdigital capacitor sensor in estimating the glucose levels in blood through the electromagnetic properties change. Interdigital capacitor configuration has been implemented in various field of application...
| Main Authors: | , , , , , , |
|---|---|
| Format: | Proceeding Paper |
| Language: | English English |
| Published: |
Institute of Electrical and Electronics Engineers Inc.
2018
|
| Subjects: | |
| Online Access: | http://irep.iium.edu.my/70142/ http://irep.iium.edu.my/70142/1/70142_Inter-digital%20sensor%20for%20non-invasive%20_SCOPUS.pdf http://irep.iium.edu.my/70142/7/70142_Inter-digital%20sensor%20for%20non-invasive%20blood.pdf |
| _version_ | 1848787239190921216 |
|---|---|
| author | Wan Morshidi, Wan Hafiy Zaharudin, Zarimin Khan, Sheroz Nordin, Anis Nurashikin Shaikh, Faraz Ahmed Adam, Ismail Abdul Kadir, Kushsairy |
| author_facet | Wan Morshidi, Wan Hafiy Zaharudin, Zarimin Khan, Sheroz Nordin, Anis Nurashikin Shaikh, Faraz Ahmed Adam, Ismail Abdul Kadir, Kushsairy |
| author_sort | Wan Morshidi, Wan Hafiy |
| building | IIUM Repository |
| collection | Online Access |
| description | This paper is to describe a contemporary approach of microwave spectroscopy by adapting the interdigital capacitor sensor in estimating the glucose levels in blood through the electromagnetic properties change. Interdigital capacitor configuration has been implemented in various field of applications nowadays such surface acoustic wave (SAW) equipment, microwave devices, chemical and biological sensors. Such a wide area of applications has proven it to be a reliable device, which can be applied in non-invasive blood glucose monitoring system. Focus of this ongoing work is to study the analytical expression for calculating the capacitance and electric field changes of the suggested inter-digital capacitor structure. This also involves the study of parameters, which affect the frequency response changes in the proposed configuration and to present a model of biological tissue. Moreover, the dependency of the capacitance on the geometrical properties of interdigital capacitor structure, electrical properties of the structure as well as those of the human biological tissue are being examined in this project. Production of a sensor based on capacitive sensing, which can be used for the non-invasive approach of blood glucose monitoring is the main target of this paper. The results include reporting changes in parameters such as relative permittivity because of blood sugar |
| first_indexed | 2025-11-14T17:21:46Z |
| format | Proceeding Paper |
| id | iium-70142 |
| institution | International Islamic University Malaysia |
| institution_category | Local University |
| language | English English |
| last_indexed | 2025-11-14T17:21:46Z |
| publishDate | 2018 |
| publisher | Institute of Electrical and Electronics Engineers Inc. |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | iium-701422019-02-22T07:15:51Z http://irep.iium.edu.my/70142/ Inter-digital sensor for non-invasive blood glucose monitoring Wan Morshidi, Wan Hafiy Zaharudin, Zarimin Khan, Sheroz Nordin, Anis Nurashikin Shaikh, Faraz Ahmed Adam, Ismail Abdul Kadir, Kushsairy TK Electrical engineering. Electronics Nuclear engineering This paper is to describe a contemporary approach of microwave spectroscopy by adapting the interdigital capacitor sensor in estimating the glucose levels in blood through the electromagnetic properties change. Interdigital capacitor configuration has been implemented in various field of applications nowadays such surface acoustic wave (SAW) equipment, microwave devices, chemical and biological sensors. Such a wide area of applications has proven it to be a reliable device, which can be applied in non-invasive blood glucose monitoring system. Focus of this ongoing work is to study the analytical expression for calculating the capacitance and electric field changes of the suggested inter-digital capacitor structure. This also involves the study of parameters, which affect the frequency response changes in the proposed configuration and to present a model of biological tissue. Moreover, the dependency of the capacitance on the geometrical properties of interdigital capacitor structure, electrical properties of the structure as well as those of the human biological tissue are being examined in this project. Production of a sensor based on capacitive sensing, which can be used for the non-invasive approach of blood glucose monitoring is the main target of this paper. The results include reporting changes in parameters such as relative permittivity because of blood sugar Institute of Electrical and Electronics Engineers Inc. 2018 Proceeding Paper PeerReviewed application/pdf en http://irep.iium.edu.my/70142/1/70142_Inter-digital%20sensor%20for%20non-invasive%20_SCOPUS.pdf application/pdf en http://irep.iium.edu.my/70142/7/70142_Inter-digital%20sensor%20for%20non-invasive%20blood.pdf Wan Morshidi, Wan Hafiy and Zaharudin, Zarimin and Khan, Sheroz and Nordin, Anis Nurashikin and Shaikh, Faraz Ahmed and Adam, Ismail and Abdul Kadir, Kushsairy (2018) Inter-digital sensor for non-invasive blood glucose monitoring. In: 2018 IEEE International Conference on Innovative Research and Development (ICIRD 2018), 11th-12th May 2018, Bangkok, Thailand. https://ieeexplore.ieee.org/document/8376339 10.1109/ICIRD.2018.8376339 |
| spellingShingle | TK Electrical engineering. Electronics Nuclear engineering Wan Morshidi, Wan Hafiy Zaharudin, Zarimin Khan, Sheroz Nordin, Anis Nurashikin Shaikh, Faraz Ahmed Adam, Ismail Abdul Kadir, Kushsairy Inter-digital sensor for non-invasive blood glucose monitoring |
| title | Inter-digital sensor for non-invasive blood glucose monitoring |
| title_full | Inter-digital sensor for non-invasive blood glucose monitoring |
| title_fullStr | Inter-digital sensor for non-invasive blood glucose monitoring |
| title_full_unstemmed | Inter-digital sensor for non-invasive blood glucose monitoring |
| title_short | Inter-digital sensor for non-invasive blood glucose monitoring |
| title_sort | inter-digital sensor for non-invasive blood glucose monitoring |
| topic | TK Electrical engineering. Electronics Nuclear engineering |
| url | http://irep.iium.edu.my/70142/ http://irep.iium.edu.my/70142/ http://irep.iium.edu.my/70142/ http://irep.iium.edu.my/70142/1/70142_Inter-digital%20sensor%20for%20non-invasive%20_SCOPUS.pdf http://irep.iium.edu.my/70142/7/70142_Inter-digital%20sensor%20for%20non-invasive%20blood.pdf |