Corneal curvature measurements utilizing a new swept-source optical coherence tomography Tomey OA-2000® and comparison with IOLMaster® 500 in pterygium patients
Introduction: Corneal curvature (CC) is an important anterior segment parameter. This study compared CC measurements conducted with two optical devices in pterygium eyes. Methods: Sixty pterygium eyes of 30 patients were enrolled in this study. CC was measured three times with the optical biometer a...
| Main Authors: | Hilmi, Mohd Radzi, Mohd Kamal, Khairidzan, Che Azemin, Mohd Zulfaezal, Ithnin, Mohd. Hafidz, Md Mustafa, Md Muziman Syah, Yusof @ Alias, Firdaus, Ahmad, Norsham |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Fakultas Kedokteran Universitas Islam Sultan Agung
2018
|
| Subjects: | |
| Online Access: | http://irep.iium.edu.my/68281/ http://irep.iium.edu.my/68281/13/Corneal%20Curvature%20Measurements%20Utilizing%20a%20New%20Swept-source%20Optical%20Coherence%20Tomography%20Tomey%20OA-2000%C2%AE%20and%20Comparison%20With%20IOL%20Master%C2%AE%20500%20in%20Pterygium%20Patients.pdf |
Similar Items
Changes in apical corneal curvature in unilateral primary Pterygium and normal adults using simulated-K and corneal irregularity measurement
by: Hilmi, Mohd Radzi, et al.
Published: (2019)
by: Hilmi, Mohd Radzi, et al.
Published: (2019)
Association of net pterygium tissue mass (dryweight) in determining changes in oculovisual functions and anterior corneal curvature relative to pterygium types
by: Che Rosli, Noor Syahira, et al.
Published: (2020)
by: Che Rosli, Noor Syahira, et al.
Published: (2020)
Pterygium recurrence and corneal stabilization point after pterygium excision using the controlled partial avulsion fibrin glue technique
by: Hilmi, Mohd Radzi, et al.
Published: (2020)
by: Hilmi, Mohd Radzi, et al.
Published: (2020)
Utilization of anterior segment optical coherence tomography enhanced high resolution corneal in measuring pterygium thickness
by: Hilmi, Mohd Radzi, et al.
Published: (2019)
by: Hilmi, Mohd Radzi, et al.
Published: (2019)
Topographic changes as predictor for determining anterior corneal curvature stabilization point subsequent to pterygium excision using controlled partial avulsion fibrin glue technique
by: Hilmi, Mohd Radzi, et al.
Published: (2019)
by: Hilmi, Mohd Radzi, et al.
Published: (2019)
Post-pterygium surgery prediction of contrast sensitivity function using fleshiness grade, length and weight of pterygium
by: Che Azemin, Mohd Zulfaezal, et al.
Published: (2020)
by: Che Azemin, Mohd Zulfaezal, et al.
Published: (2020)
Post-pterygium surgery prediction of contrast sensitivity function using fleshiness grade, redness and weight of pterygium
by: Che Azemin, Mohd Zulfaezal, et al.
Published: (2020)
by: Che Azemin, Mohd Zulfaezal, et al.
Published: (2020)
Post-pterygium surgery prediction of contrast sensitivity function using fleshiness grade, thickness and length of pterygium
by: Che Azemin, Mohd Zulfaezal, et al.
Published: (2020)
by: Che Azemin, Mohd Zulfaezal, et al.
Published: (2020)
Post-pterygium surgery prediction of contrast sensitivity function using fleshiness grade, redness, and thickness of pterygium
by: Che Azemin, Mohd Zulfaezal, et al.
Published: (2020)
by: Che Azemin, Mohd Zulfaezal, et al.
Published: (2020)
Post-pterygium surgery prediction of contrast sensitivity function using fleshiness grade, redness and length of pterygium
by: Che Azemin, Mohd Zulfaezal, et al.
Published: (2020)
by: Che Azemin, Mohd Zulfaezal, et al.
Published: (2020)
Post-pterygium surgery prediction of contrast sensitivity function using fleshiness grade, redness, thickness and weight of pterygium
by: Che Azemin, Mohd Zulfaezal, et al.
Published: (2020)
by: Che Azemin, Mohd Zulfaezal, et al.
Published: (2020)
Post-pterygium surgery prediction of contrast sensitivity function using fleshiness grade, redness, thickness and length of pterygium
by: Che Azemin, Mohd Zulfaezal, et al.
Published: (2020)
by: Che Azemin, Mohd Zulfaezal, et al.
Published: (2020)
Post-pterygium surgery prediction of contrast sensitivity function using fleshiness grade, redness, length and weight of pterygium
by: Che Azemin, Mohd Zulfaezal, et al.
Published: (2020)
by: Che Azemin, Mohd Zulfaezal, et al.
Published: (2020)
Post-pterygium surgery prediction of contrast sensitivity function using fleshiness grade, thickness, length and weight of pterygium
by: Che Azemin, Mohd Zulfaezal, et al.
Published: (2020)
by: Che Azemin, Mohd Zulfaezal, et al.
Published: (2020)
Post-pterygium surgery prediction of contrast sensitivity function using fleshiness grade, redness, thickness, length and weight of pterygium
by: Che Azemin, Mohd Zulfaezal, et al.
Published: (2020)
by: Che Azemin, Mohd Zulfaezal, et al.
Published: (2020)
Supervised pterygium fibrovascular redness grading using generalized regression neural network
by: Che Azemin, Mohd Zulfaezal, et al.
Published: (2014)
by: Che Azemin, Mohd Zulfaezal, et al.
Published: (2014)
Tear film and lid margin changes in patients with different types of primary pterygium
by: Hilmi, Mohd Radzi, et al.
Published: (2019)
by: Hilmi, Mohd Radzi, et al.
Published: (2019)
Comparative analysis of subjective and objective clinical pterygium grading based on its redness appearance
by: Hilmi, Mohd Radzi, et al.
Published: (2015)
by: Hilmi, Mohd Radzi, et al.
Published: (2015)
Benchmarked pterygium images for human and machine graders
by: Che Azemin, Mohd Zulfaezal, et al.
Published: (2016)
by: Che Azemin, Mohd Zulfaezal, et al.
Published: (2016)
GLCM texture analysis on different color space for pterygium grading
by: Che Azemin, Mohd Zulfaezal, et al.
Published: (2015)
by: Che Azemin, Mohd Zulfaezal, et al.
Published: (2015)
Corneo-pterygium total area measurements utilizing image analysis method
by: Hilmi, Mohd Radzi, et al.
Published: (2019)
by: Hilmi, Mohd Radzi, et al.
Published: (2019)
Corneo-pterygium total area measurements utilising image analysis method
by: Hilmi, Mohd Radzi, et al.
Published: (2019)
by: Hilmi, Mohd Radzi, et al.
Published: (2019)
Inter-grader reliability of a supervised pterygium redness grading system
by: Che Azemin, Mohd Zulfaezal, et al.
Published: (2016)
by: Che Azemin, Mohd Zulfaezal, et al.
Published: (2016)
Corneal thickness and curvature of one sample of young myopic population in Malaysia
by: Bariah Mohd-Ali,, et al.
Published: (2009)
by: Bariah Mohd-Ali,, et al.
Published: (2009)
Reliability measurement of corneal wavefront aberrations using corneal videokeratograph Atlas 9000
by: Mat Rejab @ Md Rejab, Noorshazana, et al.
Published: (2019)
by: Mat Rejab @ Md Rejab, Noorshazana, et al.
Published: (2019)
Reliability analysis of subjectively graded real-image pterygium based on its translucence appearance between two experienced clinicians preliminary report
by: Hilmi, Mohd Radzi, et al.
Published: (2019)
by: Hilmi, Mohd Radzi, et al.
Published: (2019)
Measurement of pterygium tissue dry weight using two different tissue preparation techniques in freeze-dry method
by: Hilmi, Mohd Radzi, et al.
Published: (2019)
by: Hilmi, Mohd Radzi, et al.
Published: (2019)
The comparison of Shape factor and mean toric keratometry between pterygium and normals
by: Hilmi, Mohd Radzi, et al.
Published: (2019)
by: Hilmi, Mohd Radzi, et al.
Published: (2019)
Prediction of changes in visual acuity and contrast sensitivity function by tissue redness after pterygium surgery
by: Hilmi, Mohd Radzi, et al.
Published: (2017)
by: Hilmi, Mohd Radzi, et al.
Published: (2017)
Measurement of contrast sensitivity using the M&S smart system II compared with the standard Pelli–Robson chart in patients with primary pterygium
by: Hilmi, Mohd Radzi, et al.
Published: (2018)
by: Hilmi, Mohd Radzi, et al.
Published: (2018)
The prevalence of pterygium and pinguecula in a clinic population
by: Kamarudin, Siti Nursyahirah, et al.
Published: (2020)
by: Kamarudin, Siti Nursyahirah, et al.
Published: (2020)
Automated inferior tear meniscus height measurement in a sequence of video
by: Che Azemin, Mohd Zulfaezal, et al.
Published: (2012)
by: Che Azemin, Mohd Zulfaezal, et al.
Published: (2012)
Reliability of pterygium redness grading software (PRGS) in describing different types of primary pterygia based on appearance
by: Mohd Radzi Hilmi,, et al.
Published: (2020)
by: Mohd Radzi Hilmi,, et al.
Published: (2020)
Effects of different types of primary pterygium on changes in oculovisual function
by: Mohd Radzi Hilmi,, et al.
Published: (2020)
by: Mohd Radzi Hilmi,, et al.
Published: (2020)
Repeatability and reproducibility of pterygium thickness measurement using OCT imaging modality of Anterior Segment Optical Coherence Tomography (AS-OCT)
by: Hilmi, Mohd Radzi, et al.
Published: (2019)
by: Hilmi, Mohd Radzi, et al.
Published: (2019)
Standard operation procedure for binocular vision cases, Department of Optometry & Visual Science, Kulliyyah of Allied Health Sciences, International Islamic University Malaysia
by: Ithnin, Mohd. Hafidz, et al.
Published: (2020)
by: Ithnin, Mohd. Hafidz, et al.
Published: (2020)
New contact lens method formula for post laser refractive surgery corneal power
by: Md Mustafa, Md Muziman Syah, et al.
Published: (2016)
by: Md Mustafa, Md Muziman Syah, et al.
Published: (2016)
Comparison of surgically induced astigmatism after superotemporal and superonasal clear corneal incisions in post phacoemulsification
by: Md Mustafa, Md Muziman Syah, et al.
Published: (2018)
by: Md Mustafa, Md Muziman Syah, et al.
Published: (2018)
Comparison of visual acuity and contrast sensitivity between unilateral primary Pterygium and normal adults utilizing computerized M&S smart system II
by: Hilmi, Mohd Radzi, et al.
Published: (2019)
by: Hilmi, Mohd Radzi, et al.
Published: (2019)
Epidemiology and genetics of catastrophizing and pain in OA
by: Harvey, Hollie
Published: (2017)
by: Harvey, Hollie
Published: (2017)
Similar Items
-
Changes in apical corneal curvature in unilateral primary Pterygium and normal adults using simulated-K and corneal irregularity measurement
by: Hilmi, Mohd Radzi, et al.
Published: (2019) -
Association of net pterygium tissue mass (dryweight) in determining changes in oculovisual functions and anterior corneal curvature relative to pterygium types
by: Che Rosli, Noor Syahira, et al.
Published: (2020) -
Pterygium recurrence and corneal stabilization point after pterygium excision using the controlled partial avulsion fibrin glue technique
by: Hilmi, Mohd Radzi, et al.
Published: (2020) -
Utilization of anterior segment optical coherence tomography enhanced high resolution corneal in measuring pterygium thickness
by: Hilmi, Mohd Radzi, et al.
Published: (2019) -
Topographic changes as predictor for determining anterior corneal curvature stabilization point subsequent to pterygium excision using controlled partial avulsion fibrin glue technique
by: Hilmi, Mohd Radzi, et al.
Published: (2019)