Corneal curvature measurements utilizing a new swept-source optical coherence tomography Tomey OA-2000® and comparison with IOLMaster® 500 in pterygium patients

Introduction: Corneal curvature (CC) is an important anterior segment parameter. This study compared CC measurements conducted with two optical devices in pterygium eyes. Methods: Sixty pterygium eyes of 30 patients were enrolled in this study. CC was measured three times with the optical biometer a...

Full description

Bibliographic Details
Main Authors: Hilmi, Mohd Radzi, Mohd Kamal, Khairidzan, Che Azemin, Mohd Zulfaezal, Ithnin, Mohd. Hafidz, Md Mustafa, Md Muziman Syah, Yusof @ Alias, Firdaus, Ahmad, Norsham
Format: Article
Language:English
Published: Fakultas Kedokteran Universitas Islam Sultan Agung 2018
Subjects:
Online Access:http://irep.iium.edu.my/68281/
http://irep.iium.edu.my/68281/13/Corneal%20Curvature%20Measurements%20Utilizing%20a%20New%20Swept-source%20Optical%20Coherence%20Tomography%20Tomey%20OA-2000%C2%AE%20and%20Comparison%20With%20IOL%20Master%C2%AE%20500%20in%20Pterygium%20Patients.pdf
_version_ 1848786912230244352
author Hilmi, Mohd Radzi
Mohd Kamal, Khairidzan
Che Azemin, Mohd Zulfaezal
Ithnin, Mohd. Hafidz
Md Mustafa, Md Muziman Syah
Yusof @ Alias, Firdaus
Ahmad, Norsham
author_facet Hilmi, Mohd Radzi
Mohd Kamal, Khairidzan
Che Azemin, Mohd Zulfaezal
Ithnin, Mohd. Hafidz
Md Mustafa, Md Muziman Syah
Yusof @ Alias, Firdaus
Ahmad, Norsham
author_sort Hilmi, Mohd Radzi
building IIUM Repository
collection Online Access
description Introduction: Corneal curvature (CC) is an important anterior segment parameter. This study compared CC measurements conducted with two optical devices in pterygium eyes. Methods: Sixty pterygium eyes of 30 patients were enrolled in this study. CC was measured three times with the optical biometer and topography-keratometer Tomey OA-2000 (Tomey Corporation, Nagoya, Japan), then with partial optical coherence interferometry (PCI) IOL Master 500 (Carl Zeiss Meditec, Dublin, CA) and data were statistically analysed. Results: The measurements revealed in a mean CC of 43.86 ± 1.57 D with Tomey OA-2000 and 43.84 ± 1.55 D with IOL Master. Distribution of data is normal, and no significance difference in CC values was detected (P = 0.952) between the two devices. Correlation between CC measurements was highly significant (r = 0. 99; P < 0.0001). The mean difference of CC values between devices was 0.017 D and 95% limit of agreement was -0.088 to 0.12. Duration taken for measurements with the standard biometer IOL Master was longer (55.17 ± 2.24 seconds) than with Tomey OA-2000 (39.88 ± 2.38 seconds) in automatic mode. Duration of manual measurement with Tomey OA-2000 in manual mode was shorter (28.57 ± 2.71 seconds). Conclusion: In pterygium eyes, CC measured with Tomey OA-2000 and IOL Master showed similar values, and high correlation was observed between these two devices. This shows that both devices can be used interchangeably. Tomey OA-2000 is better in terms of faster to operate and has its own topography systems.
first_indexed 2025-11-14T17:16:34Z
format Article
id iium-68281
institution International Islamic University Malaysia
institution_category Local University
language English
last_indexed 2025-11-14T17:16:34Z
publishDate 2018
publisher Fakultas Kedokteran Universitas Islam Sultan Agung
recordtype eprints
repository_type Digital Repository
spelling iium-682812022-06-30T06:50:33Z http://irep.iium.edu.my/68281/ Corneal curvature measurements utilizing a new swept-source optical coherence tomography Tomey OA-2000® and comparison with IOLMaster® 500 in pterygium patients Hilmi, Mohd Radzi Mohd Kamal, Khairidzan Che Azemin, Mohd Zulfaezal Ithnin, Mohd. Hafidz Md Mustafa, Md Muziman Syah Yusof @ Alias, Firdaus Ahmad, Norsham RE Ophthalmology Introduction: Corneal curvature (CC) is an important anterior segment parameter. This study compared CC measurements conducted with two optical devices in pterygium eyes. Methods: Sixty pterygium eyes of 30 patients were enrolled in this study. CC was measured three times with the optical biometer and topography-keratometer Tomey OA-2000 (Tomey Corporation, Nagoya, Japan), then with partial optical coherence interferometry (PCI) IOL Master 500 (Carl Zeiss Meditec, Dublin, CA) and data were statistically analysed. Results: The measurements revealed in a mean CC of 43.86 ± 1.57 D with Tomey OA-2000 and 43.84 ± 1.55 D with IOL Master. Distribution of data is normal, and no significance difference in CC values was detected (P = 0.952) between the two devices. Correlation between CC measurements was highly significant (r = 0. 99; P < 0.0001). The mean difference of CC values between devices was 0.017 D and 95% limit of agreement was -0.088 to 0.12. Duration taken for measurements with the standard biometer IOL Master was longer (55.17 ± 2.24 seconds) than with Tomey OA-2000 (39.88 ± 2.38 seconds) in automatic mode. Duration of manual measurement with Tomey OA-2000 in manual mode was shorter (28.57 ± 2.71 seconds). Conclusion: In pterygium eyes, CC measured with Tomey OA-2000 and IOL Master showed similar values, and high correlation was observed between these two devices. This shows that both devices can be used interchangeably. Tomey OA-2000 is better in terms of faster to operate and has its own topography systems. Fakultas Kedokteran Universitas Islam Sultan Agung 2018-11-11 Article PeerReviewed application/pdf en http://irep.iium.edu.my/68281/13/Corneal%20Curvature%20Measurements%20Utilizing%20a%20New%20Swept-source%20Optical%20Coherence%20Tomography%20Tomey%20OA-2000%C2%AE%20and%20Comparison%20With%20IOL%20Master%C2%AE%20500%20in%20Pterygium%20Patients.pdf Hilmi, Mohd Radzi and Mohd Kamal, Khairidzan and Che Azemin, Mohd Zulfaezal and Ithnin, Mohd. Hafidz and Md Mustafa, Md Muziman Syah and Yusof @ Alias, Firdaus and Ahmad, Norsham (2018) Corneal curvature measurements utilizing a new swept-source optical coherence tomography Tomey OA-2000® and comparison with IOLMaster® 500 in pterygium patients. Sains Medika: Jurnal Kedokteran dan Kesehatan, 9 (1). ISSN 2085-1545 E-ISSN 2339-093X http://jurnal.unissula.ac.id/index.php/sainsmedika/article/view/2918 10.26532/sainsmed.v9i1.2918
spellingShingle RE Ophthalmology
Hilmi, Mohd Radzi
Mohd Kamal, Khairidzan
Che Azemin, Mohd Zulfaezal
Ithnin, Mohd. Hafidz
Md Mustafa, Md Muziman Syah
Yusof @ Alias, Firdaus
Ahmad, Norsham
Corneal curvature measurements utilizing a new swept-source optical coherence tomography Tomey OA-2000® and comparison with IOLMaster® 500 in pterygium patients
title Corneal curvature measurements utilizing a new swept-source optical coherence tomography Tomey OA-2000® and comparison with IOLMaster® 500 in pterygium patients
title_full Corneal curvature measurements utilizing a new swept-source optical coherence tomography Tomey OA-2000® and comparison with IOLMaster® 500 in pterygium patients
title_fullStr Corneal curvature measurements utilizing a new swept-source optical coherence tomography Tomey OA-2000® and comparison with IOLMaster® 500 in pterygium patients
title_full_unstemmed Corneal curvature measurements utilizing a new swept-source optical coherence tomography Tomey OA-2000® and comparison with IOLMaster® 500 in pterygium patients
title_short Corneal curvature measurements utilizing a new swept-source optical coherence tomography Tomey OA-2000® and comparison with IOLMaster® 500 in pterygium patients
title_sort corneal curvature measurements utilizing a new swept-source optical coherence tomography tomey oa-2000® and comparison with iolmaster® 500 in pterygium patients
topic RE Ophthalmology
url http://irep.iium.edu.my/68281/
http://irep.iium.edu.my/68281/
http://irep.iium.edu.my/68281/
http://irep.iium.edu.my/68281/13/Corneal%20Curvature%20Measurements%20Utilizing%20a%20New%20Swept-source%20Optical%20Coherence%20Tomography%20Tomey%20OA-2000%C2%AE%20and%20Comparison%20With%20IOL%20Master%C2%AE%20500%20in%20Pterygium%20Patients.pdf