Effect of duty cycle on THD for multilevel inverter based on selective harmonic elimination technique

Multilevel inverters controlled suffers from the issue of harmonic distortion in the output voltage. Selective Harmonic Elimination (SHE) technique plays an effective role to eliminate these harmonics. The undesirable odd harmonics can be eliminated by having optimized the switching angles in S...

Full description

Bibliographic Details
Main Authors: Aboadla, Ezzidin Hassan Elmabrouk, Khan, Sheroz, Habaebi, Mohamed Hadi, Gunawan, Teddy Surya, Hamida, Belal Ahmed, Yaacob, Mashkuri, Aboadla, Ali, Khalil, Ashraf F., Muhaisen, Naser
Format: Proceeding Paper
Language:English
English
Published: IEEE 2018
Subjects:
Online Access:http://irep.iium.edu.my/67991/
http://irep.iium.edu.my/67991/1/67991_Effect%20of%20Duty%20Cycle%20on%20THD%20for%20Multilevel%20Inverter%20_article.pdf
http://irep.iium.edu.my/67991/2/67991_Effect%20of%20Duty%20Cycle%20on%20THD%20for%20Multilevel%20Inverter%20_Scopus.pdf
_version_ 1848786865634672640
author Aboadla, Ezzidin Hassan Elmabrouk
Khan, Sheroz
Habaebi, Mohamed Hadi
Gunawan, Teddy Surya
Hamida, Belal Ahmed
Yaacob, Mashkuri
Aboadla, Ali
Khalil, Ashraf F.
Muhaisen, Naser
author_facet Aboadla, Ezzidin Hassan Elmabrouk
Khan, Sheroz
Habaebi, Mohamed Hadi
Gunawan, Teddy Surya
Hamida, Belal Ahmed
Yaacob, Mashkuri
Aboadla, Ali
Khalil, Ashraf F.
Muhaisen, Naser
author_sort Aboadla, Ezzidin Hassan Elmabrouk
building IIUM Repository
collection Online Access
description Multilevel inverters controlled suffers from the issue of harmonic distortion in the output voltage. Selective Harmonic Elimination (SHE) technique plays an effective role to eliminate these harmonics. The undesirable odd harmonics can be eliminated by having optimized the switching angles in SHE signal. To optimized and obtained these switching angles, a number of nonlinear equations should be solved using a numerical method. In addition to the modulation index, by changing the value of the duty cycle the Total Harmonics Distortion (THD) will also change. In this paper, a novel Optimization Harmonic Elimination Technique (OHET) based on SHE scheme is proposed in order to minimize Total Harmonic Distortion (THD). To evaluate and investigate the performance of the proposed scheme, a seven-level cascaded inverter is simulated by MATLAB and PSIM software.
first_indexed 2025-11-14T17:15:50Z
format Proceeding Paper
id iium-67991
institution International Islamic University Malaysia
institution_category Local University
language English
English
last_indexed 2025-11-14T17:15:50Z
publishDate 2018
publisher IEEE
recordtype eprints
repository_type Digital Repository
spelling iium-679912019-08-17T04:30:19Z http://irep.iium.edu.my/67991/ Effect of duty cycle on THD for multilevel inverter based on selective harmonic elimination technique Aboadla, Ezzidin Hassan Elmabrouk Khan, Sheroz Habaebi, Mohamed Hadi Gunawan, Teddy Surya Hamida, Belal Ahmed Yaacob, Mashkuri Aboadla, Ali Khalil, Ashraf F. Muhaisen, Naser TK7800 Electronics. Computer engineering. Computer hardware. Photoelectronic devices Multilevel inverters controlled suffers from the issue of harmonic distortion in the output voltage. Selective Harmonic Elimination (SHE) technique plays an effective role to eliminate these harmonics. The undesirable odd harmonics can be eliminated by having optimized the switching angles in SHE signal. To optimized and obtained these switching angles, a number of nonlinear equations should be solved using a numerical method. In addition to the modulation index, by changing the value of the duty cycle the Total Harmonics Distortion (THD) will also change. In this paper, a novel Optimization Harmonic Elimination Technique (OHET) based on SHE scheme is proposed in order to minimize Total Harmonic Distortion (THD). To evaluate and investigate the performance of the proposed scheme, a seven-level cascaded inverter is simulated by MATLAB and PSIM software. IEEE 2018-09-19 Proceeding Paper PeerReviewed application/pdf en http://irep.iium.edu.my/67991/1/67991_Effect%20of%20Duty%20Cycle%20on%20THD%20for%20Multilevel%20Inverter%20_article.pdf application/pdf en http://irep.iium.edu.my/67991/2/67991_Effect%20of%20Duty%20Cycle%20on%20THD%20for%20Multilevel%20Inverter%20_Scopus.pdf Aboadla, Ezzidin Hassan Elmabrouk and Khan, Sheroz and Habaebi, Mohamed Hadi and Gunawan, Teddy Surya and Hamida, Belal Ahmed and Yaacob, Mashkuri and Aboadla, Ali and Khalil, Ashraf F. and Muhaisen, Naser (2018) Effect of duty cycle on THD for multilevel inverter based on selective harmonic elimination technique. In: 2018 7th International Conference on Computer Communication Engineering (ICCCE2018), 19-20 September 2018, Kuala Lumpur. https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=8539330&tag=1
spellingShingle TK7800 Electronics. Computer engineering. Computer hardware. Photoelectronic devices
Aboadla, Ezzidin Hassan Elmabrouk
Khan, Sheroz
Habaebi, Mohamed Hadi
Gunawan, Teddy Surya
Hamida, Belal Ahmed
Yaacob, Mashkuri
Aboadla, Ali
Khalil, Ashraf F.
Muhaisen, Naser
Effect of duty cycle on THD for multilevel inverter based on selective harmonic elimination technique
title Effect of duty cycle on THD for multilevel inverter based on selective harmonic elimination technique
title_full Effect of duty cycle on THD for multilevel inverter based on selective harmonic elimination technique
title_fullStr Effect of duty cycle on THD for multilevel inverter based on selective harmonic elimination technique
title_full_unstemmed Effect of duty cycle on THD for multilevel inverter based on selective harmonic elimination technique
title_short Effect of duty cycle on THD for multilevel inverter based on selective harmonic elimination technique
title_sort effect of duty cycle on thd for multilevel inverter based on selective harmonic elimination technique
topic TK7800 Electronics. Computer engineering. Computer hardware. Photoelectronic devices
url http://irep.iium.edu.my/67991/
http://irep.iium.edu.my/67991/
http://irep.iium.edu.my/67991/1/67991_Effect%20of%20Duty%20Cycle%20on%20THD%20for%20Multilevel%20Inverter%20_article.pdf
http://irep.iium.edu.my/67991/2/67991_Effect%20of%20Duty%20Cycle%20on%20THD%20for%20Multilevel%20Inverter%20_Scopus.pdf