An enhanced zero crossing based HVAC phase synchronous inverter for electrostatic generator in microgrid systems

Electrostatic Generator (ESG) faced far more challenges when it integrated with the phase synchronous inverter systems as ESG can generate high voltage DC and very low current. This high DC voltage needs to be converted and also low current of the ESG have to be increased for microgrid system which...

Full description

Bibliographic Details
Main Authors: Rahman, Tawfikur, Motakabber, S. M.A., Ibrahimy, Muhammad Ibn, Wahidur Rahman, Mozasser
Format: Article
Language:English
English
Published: Institute of Advanced Engineering and Science 2017
Subjects:
Online Access:http://irep.iium.edu.my/60278/
http://irep.iium.edu.my/60278/1/357-813-1-PB.pdf
http://irep.iium.edu.my/60278/7/An%20enhanced%20zero%20crossing%20based%20HVAC%20phase%20synchronous%20inverter%20for%20electrostatic%20generator%20in%20microgrid%20systems_SCOPUS.pdf
_version_ 1848785463740989440
author Rahman, Tawfikur
Motakabber, S. M.A.
Ibrahimy, Muhammad Ibn
Wahidur Rahman, Mozasser
author_facet Rahman, Tawfikur
Motakabber, S. M.A.
Ibrahimy, Muhammad Ibn
Wahidur Rahman, Mozasser
author_sort Rahman, Tawfikur
building IIUM Repository
collection Online Access
description Electrostatic Generator (ESG) faced far more challenges when it integrated with the phase synchronous inverter systems as ESG can generate high voltage DC and very low current. This high DC voltage needs to be converted and also low current of the ESG have to be increased for microgrid system which works generally performed by power inverter circuit. Therefore, phase synchronous inverter (PSI) is presented, to increase the inverter output current, with the aid of zero crossing voltage source controller. However, there is an issue to design the inverter which are harmonic distortion and phase angle. In this paper, a zero-crossing circuit is developed to synchronize inverter and microgrid phase and according to the simulation result, the phase angle is 3.22. In addition, an LCL filter is designed to reduce the harmonic distortion. The performance of the PSI had been demonstrated by modeling it in MATLAB2016a software. The considered parameter of the design is input voltage 10kV, switching frequency 60Hz, modulation index 0.85 and cut-off frequency 33Hz. The simulation results show that the designed inverter can greatly improve the system stability and robustness of the microgrid system and the obtained PSI system efficiency is 97.35% that performed better compared to the related inverter techniques.
first_indexed 2025-11-14T16:53:33Z
format Article
id iium-60278
institution International Islamic University Malaysia
institution_category Local University
language English
English
last_indexed 2025-11-14T16:53:33Z
publishDate 2017
publisher Institute of Advanced Engineering and Science
recordtype eprints
repository_type Digital Repository
spelling iium-602782018-04-02T07:13:35Z http://irep.iium.edu.my/60278/ An enhanced zero crossing based HVAC phase synchronous inverter for electrostatic generator in microgrid systems Rahman, Tawfikur Motakabber, S. M.A. Ibrahimy, Muhammad Ibn Wahidur Rahman, Mozasser TK3001 Distribution or transmission of electric power. The electric power circuit Electrostatic Generator (ESG) faced far more challenges when it integrated with the phase synchronous inverter systems as ESG can generate high voltage DC and very low current. This high DC voltage needs to be converted and also low current of the ESG have to be increased for microgrid system which works generally performed by power inverter circuit. Therefore, phase synchronous inverter (PSI) is presented, to increase the inverter output current, with the aid of zero crossing voltage source controller. However, there is an issue to design the inverter which are harmonic distortion and phase angle. In this paper, a zero-crossing circuit is developed to synchronize inverter and microgrid phase and according to the simulation result, the phase angle is 3.22. In addition, an LCL filter is designed to reduce the harmonic distortion. The performance of the PSI had been demonstrated by modeling it in MATLAB2016a software. The considered parameter of the design is input voltage 10kV, switching frequency 60Hz, modulation index 0.85 and cut-off frequency 33Hz. The simulation results show that the designed inverter can greatly improve the system stability and robustness of the microgrid system and the obtained PSI system efficiency is 97.35% that performed better compared to the related inverter techniques. Institute of Advanced Engineering and Science 2017 Article PeerReviewed application/pdf en http://irep.iium.edu.my/60278/1/357-813-1-PB.pdf application/pdf en http://irep.iium.edu.my/60278/7/An%20enhanced%20zero%20crossing%20based%20HVAC%20phase%20synchronous%20inverter%20for%20electrostatic%20generator%20in%20microgrid%20systems_SCOPUS.pdf Rahman, Tawfikur and Motakabber, S. M.A. and Ibrahimy, Muhammad Ibn and Wahidur Rahman, Mozasser (2017) An enhanced zero crossing based HVAC phase synchronous inverter for electrostatic generator in microgrid systems. Indonesian Journal of Electrical Engineering and Informatics, 5 (4). pp. 285-294. ISSN 2089-3272 http://section.iaesonline.com/index.php/IJEEI 10.11591/ijeei.v5i4.357
spellingShingle TK3001 Distribution or transmission of electric power. The electric power circuit
Rahman, Tawfikur
Motakabber, S. M.A.
Ibrahimy, Muhammad Ibn
Wahidur Rahman, Mozasser
An enhanced zero crossing based HVAC phase synchronous inverter for electrostatic generator in microgrid systems
title An enhanced zero crossing based HVAC phase synchronous inverter for electrostatic generator in microgrid systems
title_full An enhanced zero crossing based HVAC phase synchronous inverter for electrostatic generator in microgrid systems
title_fullStr An enhanced zero crossing based HVAC phase synchronous inverter for electrostatic generator in microgrid systems
title_full_unstemmed An enhanced zero crossing based HVAC phase synchronous inverter for electrostatic generator in microgrid systems
title_short An enhanced zero crossing based HVAC phase synchronous inverter for electrostatic generator in microgrid systems
title_sort enhanced zero crossing based hvac phase synchronous inverter for electrostatic generator in microgrid systems
topic TK3001 Distribution or transmission of electric power. The electric power circuit
url http://irep.iium.edu.my/60278/
http://irep.iium.edu.my/60278/
http://irep.iium.edu.my/60278/
http://irep.iium.edu.my/60278/1/357-813-1-PB.pdf
http://irep.iium.edu.my/60278/7/An%20enhanced%20zero%20crossing%20based%20HVAC%20phase%20synchronous%20inverter%20for%20electrostatic%20generator%20in%20microgrid%20systems_SCOPUS.pdf