Box-counting fractal dimension algorithm variations on retina images

This research work investigates the influences of FD algorithm variation on the measurement of retinal vasculature complexity. Forty retinal vasculature images from publicly available dataset were subjected to four variations of 8 box-counting FD algorithm. Different positions of box-grid were found...

Full description

Bibliographic Details
Main Authors: Che Azemin, Mohd Zulfaezal, Abd Hamid, Fadilah, Jie, Jin Wang, Kawasaki, Ryo, Kumar, Dinesh Kant
Format: Proceeding Paper
Language:English
English
Published: Springer International Publishing 2016
Subjects:
Online Access:http://irep.iium.edu.my/46904/
http://irep.iium.edu.my/46904/1/46904.pdf
http://irep.iium.edu.my/46904/4/46904_Box-counting%20fractal%20dimension_scopus.pdf
_version_ 1848783048727855104
author Che Azemin, Mohd Zulfaezal
Abd Hamid, Fadilah
Jie, Jin Wang
Kawasaki, Ryo
Kumar, Dinesh Kant
author_facet Che Azemin, Mohd Zulfaezal
Abd Hamid, Fadilah
Jie, Jin Wang
Kawasaki, Ryo
Kumar, Dinesh Kant
author_sort Che Azemin, Mohd Zulfaezal
building IIUM Repository
collection Online Access
description This research work investigates the influences of FD algorithm variation on the measurement of retinal vasculature complexity. Forty retinal vasculature images from publicly available dataset were subjected to four variations of 8 box-counting FD algorithm. Different positions of box-grid were found to significantly affect the measurement of FD (p < 0.0001, d = 0.746) due to non-identical vessels captured for measurement. By averaging multiple box-grid placements the FD mean shows no significant difference (p = 0.12, d = 0.124). Using different smoothing effect (big versus small) results in significantly different FD mean, the variation however was small (d = 0.211). The FD of skeletonized vasculature is significantly different than the segmentation (p < 0.0001) with a modest effect size (d = 0.613). More reliable FD measurement on retinal vasculature could be obtained by averaging the FD values using multiple positions of the grid.
first_indexed 2025-11-14T16:15:10Z
format Proceeding Paper
id iium-46904
institution International Islamic University Malaysia
institution_category Local University
language English
English
last_indexed 2025-11-14T16:15:10Z
publishDate 2016
publisher Springer International Publishing
recordtype eprints
repository_type Digital Repository
spelling iium-469042017-10-22T09:32:43Z http://irep.iium.edu.my/46904/ Box-counting fractal dimension algorithm variations on retina images Che Azemin, Mohd Zulfaezal Abd Hamid, Fadilah Jie, Jin Wang Kawasaki, Ryo Kumar, Dinesh Kant RE Ophthalmology TK7885 Computer engineering This research work investigates the influences of FD algorithm variation on the measurement of retinal vasculature complexity. Forty retinal vasculature images from publicly available dataset were subjected to four variations of 8 box-counting FD algorithm. Different positions of box-grid were found to significantly affect the measurement of FD (p < 0.0001, d = 0.746) due to non-identical vessels captured for measurement. By averaging multiple box-grid placements the FD mean shows no significant difference (p = 0.12, d = 0.124). Using different smoothing effect (big versus small) results in significantly different FD mean, the variation however was small (d = 0.211). The FD of skeletonized vasculature is significantly different than the segmentation (p < 0.0001) with a modest effect size (d = 0.613). More reliable FD measurement on retinal vasculature could be obtained by averaging the FD values using multiple positions of the grid. Springer International Publishing 2016 Proceeding Paper PeerReviewed application/pdf en http://irep.iium.edu.my/46904/1/46904.pdf application/pdf en http://irep.iium.edu.my/46904/4/46904_Box-counting%20fractal%20dimension_scopus.pdf Che Azemin, Mohd Zulfaezal and Abd Hamid, Fadilah and Jie, Jin Wang and Kawasaki, Ryo and Kumar, Dinesh Kant (2016) Box-counting fractal dimension algorithm variations on retina images. In: 2nd International Conference on Communication and Computer Engineering, ICOCOE 2015, 9-11 June 2015, Phuket; Thailand. http://link.springer.com/chapter/10.1007/978-3-319-24584-3_27 10.1007/978-3-319-24
spellingShingle RE Ophthalmology
TK7885 Computer engineering
Che Azemin, Mohd Zulfaezal
Abd Hamid, Fadilah
Jie, Jin Wang
Kawasaki, Ryo
Kumar, Dinesh Kant
Box-counting fractal dimension algorithm variations on retina images
title Box-counting fractal dimension algorithm variations on retina images
title_full Box-counting fractal dimension algorithm variations on retina images
title_fullStr Box-counting fractal dimension algorithm variations on retina images
title_full_unstemmed Box-counting fractal dimension algorithm variations on retina images
title_short Box-counting fractal dimension algorithm variations on retina images
title_sort box-counting fractal dimension algorithm variations on retina images
topic RE Ophthalmology
TK7885 Computer engineering
url http://irep.iium.edu.my/46904/
http://irep.iium.edu.my/46904/
http://irep.iium.edu.my/46904/