Compressed ECG biometric using cardioid graph based feature extraction

In this paper, a Cardioid graph based feature extraction technique is applied to perform compressed Electrocardiogram (ECG) biometric. To the best of our knowledge, Cardioid graph based method has not been implemented on compressed ECG before. Another merit of this methodology is that no decompressi...

Full description

Bibliographic Details
Main Authors: Iqbal, Fatema-tuz-Zohra, Sidek, Khairul Azami
Format: Article
Language:English
Published: Asian Research Publishing Network (ARPN) 2015
Subjects:
Online Access:http://irep.iium.edu.my/46654/
http://irep.iium.edu.my/46654/1/jeas_1215_3154.pdf
_version_ 1848783007022841856
author Iqbal, Fatema-tuz-Zohra
Sidek, Khairul Azami
author_facet Iqbal, Fatema-tuz-Zohra
Sidek, Khairul Azami
author_sort Iqbal, Fatema-tuz-Zohra
building IIUM Repository
collection Online Access
description In this paper, a Cardioid graph based feature extraction technique is applied to perform compressed Electrocardiogram (ECG) biometric. To the best of our knowledge, Cardioid graph based method has not been implemented on compressed ECG before. Another merit of this methodology is that no decompression of the compressed ECG signal is necessary before the recognition step. The QRS complexes obtained from the ECG signal is compressed using Discrete Wavelet Transform (DWT), followed by the Cardioid graph retrieval procedure. Compression is performed in three decomposition levels and with the first two Daubechies wavelets. Classification is conducted on all the three levels using Multilayer Perceptron (MLP) Neural Network. Maximum compression of 87.5% is achieved with an accuracy rate of 93.75%. For compression rate of 85%, the identification rate obtained is 98.75%. The same highest recognition rate of 98.75% is attained both with non-compressed and compressed data. The classification accuracy rates suggest that compressed ECG biometric with Cardioid graph based feature extraction is feasible and is capable of producing a robust biometric system.
first_indexed 2025-11-14T16:14:30Z
format Article
id iium-46654
institution International Islamic University Malaysia
institution_category Local University
language English
last_indexed 2025-11-14T16:14:30Z
publishDate 2015
publisher Asian Research Publishing Network (ARPN)
recordtype eprints
repository_type Digital Repository
spelling iium-466542017-11-16T09:45:16Z http://irep.iium.edu.my/46654/ Compressed ECG biometric using cardioid graph based feature extraction Iqbal, Fatema-tuz-Zohra Sidek, Khairul Azami TK7885 Computer engineering In this paper, a Cardioid graph based feature extraction technique is applied to perform compressed Electrocardiogram (ECG) biometric. To the best of our knowledge, Cardioid graph based method has not been implemented on compressed ECG before. Another merit of this methodology is that no decompression of the compressed ECG signal is necessary before the recognition step. The QRS complexes obtained from the ECG signal is compressed using Discrete Wavelet Transform (DWT), followed by the Cardioid graph retrieval procedure. Compression is performed in three decomposition levels and with the first two Daubechies wavelets. Classification is conducted on all the three levels using Multilayer Perceptron (MLP) Neural Network. Maximum compression of 87.5% is achieved with an accuracy rate of 93.75%. For compression rate of 85%, the identification rate obtained is 98.75%. The same highest recognition rate of 98.75% is attained both with non-compressed and compressed data. The classification accuracy rates suggest that compressed ECG biometric with Cardioid graph based feature extraction is feasible and is capable of producing a robust biometric system. Asian Research Publishing Network (ARPN) 2015 Article PeerReviewed application/pdf en http://irep.iium.edu.my/46654/1/jeas_1215_3154.pdf Iqbal, Fatema-tuz-Zohra and Sidek, Khairul Azami (2015) Compressed ECG biometric using cardioid graph based feature extraction. ARPN Journal of Engineering and Applied Sciences, 10 (22). pp. 17219-17224. ISSN 1819-6608 http://www.arpnjournals.org/jeas/research_papers/rp_2015/jeas_1215_3154.pdf
spellingShingle TK7885 Computer engineering
Iqbal, Fatema-tuz-Zohra
Sidek, Khairul Azami
Compressed ECG biometric using cardioid graph based feature extraction
title Compressed ECG biometric using cardioid graph based feature extraction
title_full Compressed ECG biometric using cardioid graph based feature extraction
title_fullStr Compressed ECG biometric using cardioid graph based feature extraction
title_full_unstemmed Compressed ECG biometric using cardioid graph based feature extraction
title_short Compressed ECG biometric using cardioid graph based feature extraction
title_sort compressed ecg biometric using cardioid graph based feature extraction
topic TK7885 Computer engineering
url http://irep.iium.edu.my/46654/
http://irep.iium.edu.my/46654/
http://irep.iium.edu.my/46654/1/jeas_1215_3154.pdf