Evaluating energy efficiency of lighting system in university library building
Library buildings consume a large quantity of energy for user services and ensuring the comfort in the building which these have produced a considerable waste on the energy usage. Lighting system is one of the largest contributors in the energy consumption and operational cost of a library buildi...
| Main Authors: | , |
|---|---|
| Format: | Proceeding Paper |
| Language: | English English |
| Published: |
2015
|
| Subjects: | |
| Online Access: | http://irep.iium.edu.my/45745/ http://irep.iium.edu.my/45745/7/SLIDES-EVALUATING_ENERGY_EFFICIENCY_OF_LIGHTING_SYSTEM_IN_UNIVERSITY.pdf http://irep.iium.edu.my/45745/17/45745.pdf |
| _version_ | 1848782840862343168 |
|---|---|
| author | Ahmad Jasmi, Siti Zulaiha Ayob, Mohd Fairullazi |
| author_facet | Ahmad Jasmi, Siti Zulaiha Ayob, Mohd Fairullazi |
| author_sort | Ahmad Jasmi, Siti Zulaiha |
| building | IIUM Repository |
| collection | Online Access |
| description | Library buildings consume a large quantity of energy for user services and ensuring the
comfort in the building which these have produced a considerable waste on the energy usage.
Lighting system is one of the largest contributors in the energy consumption and operational
cost of a library building. The implementation of energy efficiency of lighting system is
needed in order to reduce the energy consumption of lighting system. Therefore, the purpose
of this paper is to study energy efficiency of lighting system in the university library building.
The library building at the International Islamic University Malaysia (IIUM) is chosen as the
subject matter of the study. A semi-structured interview was carried out to interview four
respondents who currently in-charge in the IIUM library building operation. The results
revealed the majority of the respondents agreed that the IIUM Library building did not
implement the energy efficient criteria in fixing the lighting system which lead to high energy
consumption. A proper guideline to improve the energy efficiency of lighting system in IIUM
library was identified as the top priority strategy which proposed by the majority of the
respondents in the study. |
| first_indexed | 2025-11-14T16:11:51Z |
| format | Proceeding Paper |
| id | iium-45745 |
| institution | International Islamic University Malaysia |
| institution_category | Local University |
| language | English English |
| last_indexed | 2025-11-14T16:11:51Z |
| publishDate | 2015 |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | iium-457452021-07-19T09:00:00Z http://irep.iium.edu.my/45745/ Evaluating energy efficiency of lighting system in university library building Ahmad Jasmi, Siti Zulaiha Ayob, Mohd Fairullazi T58.4 Managerial control systems TH3301 Maintenance and repair TH7700 Illumination. Lighting TJ163.26 Energy conservation TK4125 Electric lighting TX955 Building operation and maintenance Library buildings consume a large quantity of energy for user services and ensuring the comfort in the building which these have produced a considerable waste on the energy usage. Lighting system is one of the largest contributors in the energy consumption and operational cost of a library building. The implementation of energy efficiency of lighting system is needed in order to reduce the energy consumption of lighting system. Therefore, the purpose of this paper is to study energy efficiency of lighting system in the university library building. The library building at the International Islamic University Malaysia (IIUM) is chosen as the subject matter of the study. A semi-structured interview was carried out to interview four respondents who currently in-charge in the IIUM library building operation. The results revealed the majority of the respondents agreed that the IIUM Library building did not implement the energy efficient criteria in fixing the lighting system which lead to high energy consumption. A proper guideline to improve the energy efficiency of lighting system in IIUM library was identified as the top priority strategy which proposed by the majority of the respondents in the study. 2015-11-13 Proceeding Paper NonPeerReviewed application/pdf en http://irep.iium.edu.my/45745/7/SLIDES-EVALUATING_ENERGY_EFFICIENCY_OF_LIGHTING_SYSTEM_IN_UNIVERSITY.pdf application/pdf en http://irep.iium.edu.my/45745/17/45745.pdf Ahmad Jasmi, Siti Zulaiha and Ayob, Mohd Fairullazi (2015) Evaluating energy efficiency of lighting system in university library building. In: 14th Management in Construction Research Association (MiCRA 2015) Conference and Annual General Meeting, 12th-13th Nov. 2015, Kulliyyah of Architecture and Environmental Design (KAED) International Islamic University Malaysia (IIUM). (Unpublished) https://micra14.wordpress.com/ |
| spellingShingle | T58.4 Managerial control systems TH3301 Maintenance and repair TH7700 Illumination. Lighting TJ163.26 Energy conservation TK4125 Electric lighting TX955 Building operation and maintenance Ahmad Jasmi, Siti Zulaiha Ayob, Mohd Fairullazi Evaluating energy efficiency of lighting system in university library building |
| title | Evaluating energy efficiency of lighting system in university library building |
| title_full | Evaluating energy efficiency of lighting system in university library building |
| title_fullStr | Evaluating energy efficiency of lighting system in university library building |
| title_full_unstemmed | Evaluating energy efficiency of lighting system in university library building |
| title_short | Evaluating energy efficiency of lighting system in university library building |
| title_sort | evaluating energy efficiency of lighting system in university library building |
| topic | T58.4 Managerial control systems TH3301 Maintenance and repair TH7700 Illumination. Lighting TJ163.26 Energy conservation TK4125 Electric lighting TX955 Building operation and maintenance |
| url | http://irep.iium.edu.my/45745/ http://irep.iium.edu.my/45745/ http://irep.iium.edu.my/45745/7/SLIDES-EVALUATING_ENERGY_EFFICIENCY_OF_LIGHTING_SYSTEM_IN_UNIVERSITY.pdf http://irep.iium.edu.my/45745/17/45745.pdf |