Age effects on retinal blood flow assessed using spectral-domain optical coherence tomography doppler

Purpose: To determine the impact of healthy aging upon total retinal blood flow as derived by Spectral-Domain, Optical Coherence Tomography Doppler SD-OCT. Methods: SD-OCT Doppler blood flow was non-invasively measured using the RTVue system (Optovue Inc., USA). One eye of each of 6 healthy young (...

Full description

Bibliographic Details
Main Authors: Yusof @ Alias, Firdaus, Tayyari, Faryan, Flanagan, John G, Hudson, Christopher
Format: Proceeding Paper
Language:English
Published: 2012
Subjects:
Online Access:http://irep.iium.edu.my/40365/
http://irep.iium.edu.my/40365/1/Binder1.pdf
_version_ 1848781941279555584
author Yusof @ Alias, Firdaus
Tayyari, Faryan
Flanagan, John G
Hudson, Christopher
author_facet Yusof @ Alias, Firdaus
Tayyari, Faryan
Flanagan, John G
Hudson, Christopher
author_sort Yusof @ Alias, Firdaus
building IIUM Repository
collection Online Access
description Purpose: To determine the impact of healthy aging upon total retinal blood flow as derived by Spectral-Domain, Optical Coherence Tomography Doppler SD-OCT. Methods: SD-OCT Doppler blood flow was non-invasively measured using the RTVue system (Optovue Inc., USA). One eye of each of 6 healthy young (mean age 25.7; SD 3.5 years) and 6 healthy elderly (mean age 63.5; SD 1.8 years) subjects was randomly selected for the study and dilated using Mydriacyl 1%. A double circular scanning pattern was employed. A minimum of six separate SD-OCT Doppler measurements (i.e. each separate measurement comprising a superior nasal pupil scan and an inferior nasal pupil scan) were acquired. Total retinal blood flow was calculated, using data from valid scans only, by summing flow from all detectable venules. Results: 117 of 170 images (68.82%) were determined to be valid using the DOCTORC software (Centre for Ophthalmic Optics and Lasers, CA,USA). Mean total retinal blood flow for the young group was 44.96±15.59μl/min, while for the elderly group it was 39.45±13.20 μl/min. Two-sided t-test showed no significant difference between both groups (p=0.52). Linear regression analysis showed no significant correlation between total retinal blood flow and age (r=-0.31, p=0.33). Conclusions: Preliminary data acquired using SD-OCT Doppler shows no significant difference in retinal blood flow between a young and elderly group.
first_indexed 2025-11-14T15:57:33Z
format Proceeding Paper
id iium-40365
institution International Islamic University Malaysia
institution_category Local University
language English
last_indexed 2025-11-14T15:57:33Z
publishDate 2012
recordtype eprints
repository_type Digital Repository
spelling iium-403652015-03-04T02:12:45Z http://irep.iium.edu.my/40365/ Age effects on retinal blood flow assessed using spectral-domain optical coherence tomography doppler Yusof @ Alias, Firdaus Tayyari, Faryan Flanagan, John G Hudson, Christopher QC Physics RE Ophthalmology Purpose: To determine the impact of healthy aging upon total retinal blood flow as derived by Spectral-Domain, Optical Coherence Tomography Doppler SD-OCT. Methods: SD-OCT Doppler blood flow was non-invasively measured using the RTVue system (Optovue Inc., USA). One eye of each of 6 healthy young (mean age 25.7; SD 3.5 years) and 6 healthy elderly (mean age 63.5; SD 1.8 years) subjects was randomly selected for the study and dilated using Mydriacyl 1%. A double circular scanning pattern was employed. A minimum of six separate SD-OCT Doppler measurements (i.e. each separate measurement comprising a superior nasal pupil scan and an inferior nasal pupil scan) were acquired. Total retinal blood flow was calculated, using data from valid scans only, by summing flow from all detectable venules. Results: 117 of 170 images (68.82%) were determined to be valid using the DOCTORC software (Centre for Ophthalmic Optics and Lasers, CA,USA). Mean total retinal blood flow for the young group was 44.96±15.59μl/min, while for the elderly group it was 39.45±13.20 μl/min. Two-sided t-test showed no significant difference between both groups (p=0.52). Linear regression analysis showed no significant correlation between total retinal blood flow and age (r=-0.31, p=0.33). Conclusions: Preliminary data acquired using SD-OCT Doppler shows no significant difference in retinal blood flow between a young and elderly group. 2012 Proceeding Paper PeerReviewed application/pdf en http://irep.iium.edu.my/40365/1/Binder1.pdf Yusof @ Alias, Firdaus and Tayyari, Faryan and Flanagan, John G and Hudson, Christopher (2012) Age effects on retinal blood flow assessed using spectral-domain optical coherence tomography doppler. In: ARVO 2012 Annual Meeting, 10 May 2012, Fort Lauderdale, FL, USA. http://www.arvo.org/Annual_Meeting/2012/Program/
spellingShingle QC Physics
RE Ophthalmology
Yusof @ Alias, Firdaus
Tayyari, Faryan
Flanagan, John G
Hudson, Christopher
Age effects on retinal blood flow assessed using spectral-domain optical coherence tomography doppler
title Age effects on retinal blood flow assessed using spectral-domain optical coherence tomography doppler
title_full Age effects on retinal blood flow assessed using spectral-domain optical coherence tomography doppler
title_fullStr Age effects on retinal blood flow assessed using spectral-domain optical coherence tomography doppler
title_full_unstemmed Age effects on retinal blood flow assessed using spectral-domain optical coherence tomography doppler
title_short Age effects on retinal blood flow assessed using spectral-domain optical coherence tomography doppler
title_sort age effects on retinal blood flow assessed using spectral-domain optical coherence tomography doppler
topic QC Physics
RE Ophthalmology
url http://irep.iium.edu.my/40365/
http://irep.iium.edu.my/40365/
http://irep.iium.edu.my/40365/1/Binder1.pdf