Hemodynamic response to exercise and head-up tilt of patients implanted with a Rotary Blood Pump : a computational modeling study
The present study investigates the response of implantable rotary blood pump (IRBP)-assisted patients to exercise and head-up tilt (HUT), as well as the effect of alterations in the model parameter values on this response, using validated numerical models. Furthermore, we comparatively evaluate th...
| Main Authors: | Lim, Einly, Salamonsen, Robert Francis, Mansouri, Mahdi, Gaddum, Nicholas, Mason, David Glen, Timms, Daniel L., Stevens, Michael Charles, Fraser, John, Akmeliawati, Rini, Lovell, Nigel Hamilton |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
4 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
2015
|
| Subjects: | |
| Online Access: | http://irep.iium.edu.my/39284/ http://irep.iium.edu.my/39284/1/Lim2014_Hemodynamic_Response_to_Exercise_and_Head-Up_Tilt_of_Patients_Implanted_With_a_Rotary_Blood_Pump_A_Computational_Modeling_Study.pdf |
Similar Items
Preload-based starling-like control of rotary blood pumps: an in-vitro evaluation
by: Mansouri, Mahdi, et al.
Published: (2017)
by: Mansouri, Mahdi, et al.
Published: (2017)
Preload-based starling-like control for rotary blood pumps: numerical comparison with pulsatility control and constant speed operation
by: Mansouri, Mahdi, et al.
Published: (2015)
by: Mansouri, Mahdi, et al.
Published: (2015)
Physiological control of an implantable rotary blood pump
/ Mahdi Mansouri
by: Mahdi , Mansouri
Published: (2016)
by: Mahdi , Mansouri
Published: (2016)
Noninvasive detection of physiologically significant pumping states in an implantable rotary blood pump / Ooi Hui Lee
by: Ooi , Hui Lee
Published: (2014)
by: Ooi , Hui Lee
Published: (2014)
PSO-Based robust controller design for a rotary inverted pendulum stabilization
by: Solihin, Mahmud Iwan, et al.
Published: (2011)
by: Solihin, Mahmud Iwan, et al.
Published: (2011)
Vibration control of two-mass rotary system using improved NCTF controller for positioning systems
by: Mohd. Yakub, Mohd. Fitri, et al.
Published: (2010)
by: Mohd. Yakub, Mohd. Fitri, et al.
Published: (2010)
A Perspective Review on Numerical Simulations of Hemodynamics in Aortic Dissection
by: Wan Ab Naim, Naimah, et al.
Published: (2014)
by: Wan Ab Naim, Naimah, et al.
Published: (2014)
The hemodynamic effects of paravalvular leakage using fluid structure interaction; transcatheter aortic valve implantation patient
by: Basri, Adi Azriff, et al.
Published: (2016)
by: Basri, Adi Azriff, et al.
Published: (2016)
Proposal for a cost-effective centrifugal rotary blood pump: design of a hybrid magnetic/hydrodynamic bearing
by: Hilton, Andrew
Published: (2010)
by: Hilton, Andrew
Published: (2010)
Tilt Detection Of Connectors Using Phase Shifting.
by: Retnasamy, V, et al.
Published: (2007)
by: Retnasamy, V, et al.
Published: (2007)
Computer simulation of rotary forging
by: Grieve, David G.
Published: (1991)
by: Grieve, David G.
Published: (1991)
Visual Inspection System To Detect
Connector Tilts In Pcbas
by: Retnasamy, Vithyacharan
Published: (2005)
by: Retnasamy, Vithyacharan
Published: (2005)
Simulation & documentation on cardiovascular & hemodynamic status of patients
by: Jamaludin, Sumaiyah @ ThandarSoe
Published: (2016)
by: Jamaludin, Sumaiyah @ ThandarSoe
Published: (2016)
Visit from Rotary Club of Season - Rotary International District (South Korea), 21 January 2016
by: Universiti Malaysia Sarawak, Centre for Academic Information Services
Published: (2016)
by: Universiti Malaysia Sarawak, Centre for Academic Information Services
Published: (2016)
Hemodynamic effect of calcifed plaque on blood flow in carotid artery disease: A preliminary study - Hemodynamic effect of calcified plaque
by: Sun, Zhonghua, et al.
Published: (2009)
by: Sun, Zhonghua, et al.
Published: (2009)
Dripping dynamics from a tilted nozzle / Amaraja Taur
by: Amaraja, Taur
Published: (2014)
by: Amaraja, Taur
Published: (2014)
Adaptation to implied tilt: extensive spatial extrapolation of orientation gradients
by: Roach, Neil W., et al.
Published: (2013)
by: Roach, Neil W., et al.
Published: (2013)
On tilt and curvature dependent errors and the calibration of coherence scanning interferometry
by: Su, Rong, et al.
Published: (2017)
by: Su, Rong, et al.
Published: (2017)
Analytical investigation of collector optimum tilt angle at low latitude
by: Aja, Aja, et al.
Published: (2013)
by: Aja, Aja, et al.
Published: (2013)
Autonomous control of tilt tri-rotor unmanned aerial vehicle
by: Olanrewaju, Rashidah Funke, et al.
Published: (2016)
by: Olanrewaju, Rashidah Funke, et al.
Published: (2016)
Automatic pan-tilt camera positioning system for motion tracking
by: Wong, Teck Chang
Published: (2004)
by: Wong, Teck Chang
Published: (2004)
Optimised intelligent tilt controller scheme using genetic algorithms
by: Zamzuri, Hairi, et al.
Published: (2006)
by: Zamzuri, Hairi, et al.
Published: (2006)
Hemodynamic Solution Computation and Pathological Analysis in the Circle of Willis
by: Sui, J., et al.
Published: (2018)
by: Sui, J., et al.
Published: (2018)
Computation of hemodynamics in the left coronary artery with variable angulations
by: Chachaina, Thanapong, et al.
Published: (2011)
by: Chachaina, Thanapong, et al.
Published: (2011)
The effect of stent void area on hemodynamics in cerebral aneurysm
by: Suriani, Abd Rahman
Published: (2009)
by: Suriani, Abd Rahman
Published: (2009)
Input shaping and PID controller for rotary crane
by: Enti Nashila, Riazuddin
Published: (2012)
by: Enti Nashila, Riazuddin
Published: (2012)
Development of an image rotary encoder for motion control
by: Ismayuzri, Ishak
Published: (2013)
by: Ismayuzri, Ishak
Published: (2013)
Evaluation of a Laboratory Asphalt Rotary Compactor
by: Haghighi, Hamed
Published: (2009)
by: Haghighi, Hamed
Published: (2009)
Solar energy and daylight on tilt planes under CIE standard skies
by: Lou, Siwei, et al.
Published: (2020)
by: Lou, Siwei, et al.
Published: (2020)
Properties of tilted univalent analytic functions of order δ / Sidik Rathi
by: Rathi, Sidik
Published: (2015)
by: Rathi, Sidik
Published: (2015)
Optimisation of tilt angles for fixed PV Panel via computational algorithm
by: Tang, Hong Wei
Published: (2022)
by: Tang, Hong Wei
Published: (2022)
Reconfigurable metamaterial structure for 5G beam tilting antenna applications
by: F. Esmail, Bashar A., et al.
Published: (2020)
by: F. Esmail, Bashar A., et al.
Published: (2020)
Drone fault tolerance strategy by allowing remaining rotor to pan and tilt
by: Zaludin, Zairil
Published: (2024)
by: Zaludin, Zairil
Published: (2024)
Effect of mould tilt angle on the mechanical properties of as-cast aluminum alloy
by: Hamzah, E., et al.
Published: (2002)
by: Hamzah, E., et al.
Published: (2002)
Computational hemodynamic analysis of stenosed coronary artery / Sarfaraz Kamangar
by: Sarfaraz , Kamangar
Published: (2016)
by: Sarfaraz , Kamangar
Published: (2016)
Gabapentin for the hemodynamic response to intubation: systematic review and meta-analysis
by: Doleman, Brett, et al.
Published: (2016)
by: Doleman, Brett, et al.
Published: (2016)
Modeling the effect of different locations of carotid atherosclerosis on hemodynamics parameters
by: A. Fahmi Huwaidi, M. Noor, et al.
Published: (2022)
by: A. Fahmi Huwaidi, M. Noor, et al.
Published: (2022)
Kinematic analysis of rotary car parking system mechanism
by: Nursalim, Iim, et al.
Published: (2018)
by: Nursalim, Iim, et al.
Published: (2018)
A computer package for simulation and analysis of rotary forging
by: Mansour, Saeed
Published: (1988)
by: Mansour, Saeed
Published: (1988)
Design and development of controller of a rotary crane system
by: Ali Azhar, F.E., et al.
Published: (2012)
by: Ali Azhar, F.E., et al.
Published: (2012)
Similar Items
-
Preload-based starling-like control of rotary blood pumps: an in-vitro evaluation
by: Mansouri, Mahdi, et al.
Published: (2017) -
Preload-based starling-like control for rotary blood pumps: numerical comparison with pulsatility control and constant speed operation
by: Mansouri, Mahdi, et al.
Published: (2015) -
Physiological control of an implantable rotary blood pump
/ Mahdi Mansouri
by: Mahdi , Mansouri
Published: (2016) -
Noninvasive detection of physiologically significant pumping states in an implantable rotary blood pump / Ooi Hui Lee
by: Ooi , Hui Lee
Published: (2014) -
PSO-Based robust controller design for a rotary inverted pendulum stabilization
by: Solihin, Mahmud Iwan, et al.
Published: (2011)