Minimally invasive haemodynamic monitoring: PiCCO

Resuscitation of critically ill patients in the intensive care setting is a complex process requiring the accurate measurement of haemodynamic parameters i.e. cardiac output, stroke volume variation and systemic vascular resistance. Haemodynamic monitoring data is used to optimize the balance betwee...

Full description

Bibliographic Details
Main Author: Mat Nor, Mohd Basri
Format: Proceeding Paper
Language:English
English
Published: 2013
Subjects:
Online Access:http://irep.iium.edu.my/35229/
http://irep.iium.edu.my/35229/1/ASMIC2013_book_picco.pdf
http://irep.iium.edu.my/35229/2/PiCCO_Technology_03-2013_BASRI.pdf
_version_ 1848781024806305792
author Mat Nor, Mohd Basri
author_facet Mat Nor, Mohd Basri
author_sort Mat Nor, Mohd Basri
building IIUM Repository
collection Online Access
description Resuscitation of critically ill patients in the intensive care setting is a complex process requiring the accurate measurement of haemodynamic parameters i.e. cardiac output, stroke volume variation and systemic vascular resistance. Haemodynamic monitoring data is used to optimize the balance between tissue oxygenation supply and demand and effectively combat global tissue hypoxia, shock and multi organ failure in critically ill patients. This information guides treatment and prevents morbidity and mortality. Invasive haemodynamic monitoring has been the connerstone of the care of the critically ill and haemodynamically unstable patient. Nevertheless, several concerns have been raised regarding its invasiveness and associated complications. This has led to the development of a number of less invasive technologies for cardiac output determination.
first_indexed 2025-11-14T15:42:59Z
format Proceeding Paper
id iium-35229
institution International Islamic University Malaysia
institution_category Local University
language English
English
last_indexed 2025-11-14T15:42:59Z
publishDate 2013
recordtype eprints
repository_type Digital Repository
spelling iium-352292020-07-15T03:02:29Z http://irep.iium.edu.my/35229/ Minimally invasive haemodynamic monitoring: PiCCO Mat Nor, Mohd Basri R Medicine (General) Resuscitation of critically ill patients in the intensive care setting is a complex process requiring the accurate measurement of haemodynamic parameters i.e. cardiac output, stroke volume variation and systemic vascular resistance. Haemodynamic monitoring data is used to optimize the balance between tissue oxygenation supply and demand and effectively combat global tissue hypoxia, shock and multi organ failure in critically ill patients. This information guides treatment and prevents morbidity and mortality. Invasive haemodynamic monitoring has been the connerstone of the care of the critically ill and haemodynamically unstable patient. Nevertheless, several concerns have been raised regarding its invasiveness and associated complications. This has led to the development of a number of less invasive technologies for cardiac output determination. 2013-09-19 Proceeding Paper NonPeerReviewed application/pdf en http://irep.iium.edu.my/35229/1/ASMIC2013_book_picco.pdf application/pdf en http://irep.iium.edu.my/35229/2/PiCCO_Technology_03-2013_BASRI.pdf Mat Nor, Mohd Basri (2013) Minimally invasive haemodynamic monitoring: PiCCO. In: Annual Scientifc Meeting on Intensive Care (ASMIC 2013), 19-22 September 2013, Shangri-La Hotel, Kuala Lumpur. (Unpublished) http://www.acadmed.org.my/eventsmaster.cfm?&menuid=33&action=viewevent&retrieveid=205
spellingShingle R Medicine (General)
Mat Nor, Mohd Basri
Minimally invasive haemodynamic monitoring: PiCCO
title Minimally invasive haemodynamic monitoring: PiCCO
title_full Minimally invasive haemodynamic monitoring: PiCCO
title_fullStr Minimally invasive haemodynamic monitoring: PiCCO
title_full_unstemmed Minimally invasive haemodynamic monitoring: PiCCO
title_short Minimally invasive haemodynamic monitoring: PiCCO
title_sort minimally invasive haemodynamic monitoring: picco
topic R Medicine (General)
url http://irep.iium.edu.my/35229/
http://irep.iium.edu.my/35229/
http://irep.iium.edu.my/35229/1/ASMIC2013_book_picco.pdf
http://irep.iium.edu.my/35229/2/PiCCO_Technology_03-2013_BASRI.pdf