Development of a micromolding process

This paper presents the simulating and experimental results of a micromolding process for fabrication of threedimensional (3D) microcomponents. The maskless process utilizes a micro electrical discharging system for bulk machining, then finish machining using focused-ion beam to sputter the mold m...

Full description

Bibliographic Details
Main Authors: Hung, N. P., Yuan, S., Lee, E. C. W., Ali, Mohammad Yeakub
Format: Proceeding Paper
Language:English
Published: 2001
Subjects:
Online Access:http://irep.iium.edu.my/27139/
http://irep.iium.edu.my/27139/1/035_DTIP-SPIE_France_2001_317-328_Hung.pdf
_version_ 1848779767078191104
author Hung, N. P.
Yuan, S.
Lee, E. C. W.
Ali, Mohammad Yeakub
author_facet Hung, N. P.
Yuan, S.
Lee, E. C. W.
Ali, Mohammad Yeakub
author_sort Hung, N. P.
building IIUM Repository
collection Online Access
description This paper presents the simulating and experimental results of a micromolding process for fabrication of threedimensional (3D) microcomponents. The maskless process utilizes a micro electrical discharging system for bulk machining, then finish machining using focused-ion beam to sputter the mold microcavity, which is then filled with various types of plastics. Simulation using commercially available software reveals possible problems in micromolding, and the simulation results of microgears (φ100-1000μm diameter, 1:1 aspect ratio) are compared with those from actually molded microgears. Although the software prohibits modeling of a stand-alone microgear with diameter below φ1000μm when using a 2.5D model and φ220μm for a 3D model, the simulation succeeds upon integrating a microgear of φ100μm with a larger base. Selecting the polymers from the built-in data bank, the simulation pinpoints locations for trapped gas, predicts filling time, volumetric shrinkage, uniformity, and distribution of pressure, shear rate, stress.... It correctly predicts underfilling of the cavity when the mold temperature is below a threshold, but fails to locate the weld lines. Minimum channel sizes for proper flow of several plastics are presented, and the mold temperature must be controlled for proper flow of polymer into a microcavity. The measured viscosity of tested polymers compliments the experimental and simulating results.
first_indexed 2025-11-14T15:23:00Z
format Proceeding Paper
id iium-27139
institution International Islamic University Malaysia
institution_category Local University
language English
last_indexed 2025-11-14T15:23:00Z
publishDate 2001
recordtype eprints
repository_type Digital Repository
spelling iium-271392013-09-06T07:42:45Z http://irep.iium.edu.my/27139/ Development of a micromolding process Hung, N. P. Yuan, S. Lee, E. C. W. Ali, Mohammad Yeakub TS Manufactures This paper presents the simulating and experimental results of a micromolding process for fabrication of threedimensional (3D) microcomponents. The maskless process utilizes a micro electrical discharging system for bulk machining, then finish machining using focused-ion beam to sputter the mold microcavity, which is then filled with various types of plastics. Simulation using commercially available software reveals possible problems in micromolding, and the simulation results of microgears (φ100-1000μm diameter, 1:1 aspect ratio) are compared with those from actually molded microgears. Although the software prohibits modeling of a stand-alone microgear with diameter below φ1000μm when using a 2.5D model and φ220μm for a 3D model, the simulation succeeds upon integrating a microgear of φ100μm with a larger base. Selecting the polymers from the built-in data bank, the simulation pinpoints locations for trapped gas, predicts filling time, volumetric shrinkage, uniformity, and distribution of pressure, shear rate, stress.... It correctly predicts underfilling of the cavity when the mold temperature is below a threshold, but fails to locate the weld lines. Minimum channel sizes for proper flow of several plastics are presented, and the mold temperature must be controlled for proper flow of polymer into a microcavity. The measured viscosity of tested polymers compliments the experimental and simulating results. 2001 Proceeding Paper PeerReviewed application/pdf en http://irep.iium.edu.my/27139/1/035_DTIP-SPIE_France_2001_317-328_Hung.pdf Hung, N. P. and Yuan, S. and Lee, E. C. W. and Ali, Mohammad Yeakub (2001) Development of a micromolding process. In: International Symposium on Design, Test, Integration and Packaging of MEMS/MOEMS 2001, 25-27 April 2001, Cannes, France.
spellingShingle TS Manufactures
Hung, N. P.
Yuan, S.
Lee, E. C. W.
Ali, Mohammad Yeakub
Development of a micromolding process
title Development of a micromolding process
title_full Development of a micromolding process
title_fullStr Development of a micromolding process
title_full_unstemmed Development of a micromolding process
title_short Development of a micromolding process
title_sort development of a micromolding process
topic TS Manufactures
url http://irep.iium.edu.my/27139/
http://irep.iium.edu.my/27139/1/035_DTIP-SPIE_France_2001_317-328_Hung.pdf