Fire safety and protection measures in heritage buildings with special consideration on museum buildings in Malaysia

Fire is one of the greatest threats to heritage buildings not only to the buildings’ occupants but also to the buildings’ fabrics and contents. Heritage buildings are irreplaceable, in addition to being vulnerable to fire due to several factors: large scale buildings, flammable priceless contents, a...

Full description

Bibliographic Details
Main Author: Salleh, Nurul Hamiruddin
Format: Proceeding Paper
Language:English
Published: 2012
Subjects:
Online Access:http://irep.iium.edu.my/24302/
http://irep.iium.edu.my/24302/1/Fire_safety_and_protection.pdf
_version_ 1848779279852109824
author Salleh, Nurul Hamiruddin
author_facet Salleh, Nurul Hamiruddin
author_sort Salleh, Nurul Hamiruddin
building IIUM Repository
collection Online Access
description Fire is one of the greatest threats to heritage buildings not only to the buildings’ occupants but also to the buildings’ fabrics and contents. Heritage buildings are irreplaceable, in addition to being vulnerable to fire due to several factors: large scale buildings, flammable priceless contents, and weak existing structures to fire resistance. Unfortunately, until today, there are no sufficient legislations or guidelines on fire safety for heritage buildings in Malaysia. This study audits the current fire safety measures and examines the management of fire safety in Malaysian heritage buildings that focuses on museum buildings. A combination of observations, interviews, questionnaires and case studies was employed to provide primary data in this study. Three museums were selected as case studies; each of them represented different criteria in order to gather various information and comparison as much as possible. Fire safety and protection measures in the studied buildings have been audited with reference to the requirements of the UBBL 1984, the Fire Services Act 1988, the Occupational Safety and Health Act 1994 and four relevant Malaysian Standards. The finding shows that there are several fire safety weaknesses in the heritage buildings that could put people and heritage properties on fire risks.
first_indexed 2025-11-14T15:15:15Z
format Proceeding Paper
id iium-24302
institution International Islamic University Malaysia
institution_category Local University
language English
last_indexed 2025-11-14T15:15:15Z
publishDate 2012
recordtype eprints
repository_type Digital Repository
spelling iium-243022021-07-22T17:21:28Z http://irep.iium.edu.my/24302/ Fire safety and protection measures in heritage buildings with special consideration on museum buildings in Malaysia Salleh, Nurul Hamiruddin NA Architecture NA2400 Museums. Exhibitions Fire is one of the greatest threats to heritage buildings not only to the buildings’ occupants but also to the buildings’ fabrics and contents. Heritage buildings are irreplaceable, in addition to being vulnerable to fire due to several factors: large scale buildings, flammable priceless contents, and weak existing structures to fire resistance. Unfortunately, until today, there are no sufficient legislations or guidelines on fire safety for heritage buildings in Malaysia. This study audits the current fire safety measures and examines the management of fire safety in Malaysian heritage buildings that focuses on museum buildings. A combination of observations, interviews, questionnaires and case studies was employed to provide primary data in this study. Three museums were selected as case studies; each of them represented different criteria in order to gather various information and comparison as much as possible. Fire safety and protection measures in the studied buildings have been audited with reference to the requirements of the UBBL 1984, the Fire Services Act 1988, the Occupational Safety and Health Act 1994 and four relevant Malaysian Standards. The finding shows that there are several fire safety weaknesses in the heritage buildings that could put people and heritage properties on fire risks. 2012 Proceeding Paper PeerReviewed application/pdf en http://irep.iium.edu.my/24302/1/Fire_safety_and_protection.pdf Salleh, Nurul Hamiruddin (2012) Fire safety and protection measures in heritage buildings with special consideration on museum buildings in Malaysia. In: 1st International Conference on Innovation and Technology for Sustainable Built Environment 2012 (ICITSBE 2012), 16-17 April 2012, Sri Iskandar, Perak. http://www.perak.uitm.edu.my/ncitsbe2012/
spellingShingle NA Architecture
NA2400 Museums. Exhibitions
Salleh, Nurul Hamiruddin
Fire safety and protection measures in heritage buildings with special consideration on museum buildings in Malaysia
title Fire safety and protection measures in heritage buildings with special consideration on museum buildings in Malaysia
title_full Fire safety and protection measures in heritage buildings with special consideration on museum buildings in Malaysia
title_fullStr Fire safety and protection measures in heritage buildings with special consideration on museum buildings in Malaysia
title_full_unstemmed Fire safety and protection measures in heritage buildings with special consideration on museum buildings in Malaysia
title_short Fire safety and protection measures in heritage buildings with special consideration on museum buildings in Malaysia
title_sort fire safety and protection measures in heritage buildings with special consideration on museum buildings in malaysia
topic NA Architecture
NA2400 Museums. Exhibitions
url http://irep.iium.edu.my/24302/
http://irep.iium.edu.my/24302/
http://irep.iium.edu.my/24302/1/Fire_safety_and_protection.pdf