Serum-protein effects on the detection of the B-blocker propranolol by ion-transfer voltammetry at a micro-ITIES array

In this work, the effect of the serum protein, bovine serum albumin (BSA), on the detection of propranololin artificial serum by ion-transfer voltammetry at an array of micro-interfaces between two immiscibleelectrolyte solutions (ITIES) is presented. Cyclic voltammetry (CV), differential pulse volt...

Full description

Bibliographic Details
Main Authors: Collins, C., Lyons, C., Strutwolf, J., Arrigan, Damien
Format: Journal Article
Published: Elsevier 2010
Subjects:
Online Access:http://hdl.handle.net/20.500.11937/9749
_version_ 1848746039445553152
author Collins, C.
Lyons, C.
Strutwolf, J.
Arrigan, Damien
author_facet Collins, C.
Lyons, C.
Strutwolf, J.
Arrigan, Damien
author_sort Collins, C.
building Curtin Institutional Repository
collection Online Access
description In this work, the effect of the serum protein, bovine serum albumin (BSA), on the detection of propranololin artificial serum by ion-transfer voltammetry at an array of micro-interfaces between two immiscibleelectrolyte solutions (ITIES) is presented. Cyclic voltammetry (CV), differential pulse voltammetry(DPV), and differential pulse stripping voltammetry (DPSV) were examined for the detection of low concentrationsof propranolol. Both CV and DPV had an interference effect from BSA, manifested as lowercurrents in the presence of the protein. DPSV proved to be the most effective technique, enabling thedetection of 0.05M propranolol in the presence of BSA. The DPSV method employed a preconditioningstep as well as a preconcentration step followed by the analytical signal generation step. The latterwas based on the back-transfer of the drug across the ITIES. The preconcentration step was crucialto prevention of the adverse effects of BSA on the voltammetric detection. These results demonstratethat serum-protein effects on drug detection at low concentrations can be eliminated by use of DPSV atarrays of ITIES. CVs of propranolol with increasing concentrations of BSA revealed the influence of thedrug–protein binding interaction, with decreases in current but no change in transfer potential. Therapeuticconcentrations of propranolol were detected, demonstrating the viability of this approach forbioanalytical investigations.
first_indexed 2025-11-14T06:26:55Z
format Journal Article
id curtin-20.500.11937-9749
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T06:26:55Z
publishDate 2010
publisher Elsevier
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-97492017-09-13T14:50:15Z Serum-protein effects on the detection of the B-blocker propranolol by ion-transfer voltammetry at a micro-ITIES array Collins, C. Lyons, C. Strutwolf, J. Arrigan, Damien Immiscible electrolyte solutions Bioanalytical Drug monitoring Liquid/liquid interface Voltammetry In this work, the effect of the serum protein, bovine serum albumin (BSA), on the detection of propranololin artificial serum by ion-transfer voltammetry at an array of micro-interfaces between two immiscibleelectrolyte solutions (ITIES) is presented. Cyclic voltammetry (CV), differential pulse voltammetry(DPV), and differential pulse stripping voltammetry (DPSV) were examined for the detection of low concentrationsof propranolol. Both CV and DPV had an interference effect from BSA, manifested as lowercurrents in the presence of the protein. DPSV proved to be the most effective technique, enabling thedetection of 0.05M propranolol in the presence of BSA. The DPSV method employed a preconditioningstep as well as a preconcentration step followed by the analytical signal generation step. The latterwas based on the back-transfer of the drug across the ITIES. The preconcentration step was crucialto prevention of the adverse effects of BSA on the voltammetric detection. These results demonstratethat serum-protein effects on drug detection at low concentrations can be eliminated by use of DPSV atarrays of ITIES. CVs of propranolol with increasing concentrations of BSA revealed the influence of thedrug–protein binding interaction, with decreases in current but no change in transfer potential. Therapeuticconcentrations of propranolol were detected, demonstrating the viability of this approach forbioanalytical investigations. 2010 Journal Article http://hdl.handle.net/20.500.11937/9749 10.1016/j.talanta.2009.10.060 Elsevier restricted
spellingShingle Immiscible electrolyte solutions
Bioanalytical
Drug monitoring
Liquid/liquid interface
Voltammetry
Collins, C.
Lyons, C.
Strutwolf, J.
Arrigan, Damien
Serum-protein effects on the detection of the B-blocker propranolol by ion-transfer voltammetry at a micro-ITIES array
title Serum-protein effects on the detection of the B-blocker propranolol by ion-transfer voltammetry at a micro-ITIES array
title_full Serum-protein effects on the detection of the B-blocker propranolol by ion-transfer voltammetry at a micro-ITIES array
title_fullStr Serum-protein effects on the detection of the B-blocker propranolol by ion-transfer voltammetry at a micro-ITIES array
title_full_unstemmed Serum-protein effects on the detection of the B-blocker propranolol by ion-transfer voltammetry at a micro-ITIES array
title_short Serum-protein effects on the detection of the B-blocker propranolol by ion-transfer voltammetry at a micro-ITIES array
title_sort serum-protein effects on the detection of the b-blocker propranolol by ion-transfer voltammetry at a micro-ities array
topic Immiscible electrolyte solutions
Bioanalytical
Drug monitoring
Liquid/liquid interface
Voltammetry
url http://hdl.handle.net/20.500.11937/9749