A novel mitigation technique to eliminate the harmonic effects on over-current relays

In this thesis, overcurrent relay performance and relay co-ordination were analyzed with and without the presence of harmonic contents in the power system network using the IEEE 30 bus network. The two analyses proved the different results of overcurrent relay performance under a fault condition. In...

Full description

Bibliographic Details
Main Author: Tin, Hillary
Format: Thesis
Language:English
Published: Curtin University 2013
Online Access:http://hdl.handle.net/20.500.11937/93
_version_ 1848743287366615040
author Tin, Hillary
author_facet Tin, Hillary
author_sort Tin, Hillary
building Curtin Institutional Repository
collection Online Access
description In this thesis, overcurrent relay performance and relay co-ordination were analyzed with and without the presence of harmonic contents in the power system network using the IEEE 30 bus network. The two analyses proved the different results of overcurrent relay performance under a fault condition. Initially, shunt passive filters were used to overcome the problem, but they become unreliable and active filters were proposed. However, the active filters became dissatisfaction and Hybrid Filters become more in interest. This project implemented and analyzed the Hybrid Filters and its results which were desirable.
first_indexed 2025-11-14T05:43:10Z
format Thesis
id curtin-20.500.11937-93
institution Curtin University Malaysia
institution_category Local University
language English
last_indexed 2025-11-14T05:43:10Z
publishDate 2013
publisher Curtin University
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-932017-02-20T06:42:17Z A novel mitigation technique to eliminate the harmonic effects on over-current relays Tin, Hillary In this thesis, overcurrent relay performance and relay co-ordination were analyzed with and without the presence of harmonic contents in the power system network using the IEEE 30 bus network. The two analyses proved the different results of overcurrent relay performance under a fault condition. Initially, shunt passive filters were used to overcome the problem, but they become unreliable and active filters were proposed. However, the active filters became dissatisfaction and Hybrid Filters become more in interest. This project implemented and analyzed the Hybrid Filters and its results which were desirable. 2013 Thesis http://hdl.handle.net/20.500.11937/93 en Curtin University fulltext
spellingShingle Tin, Hillary
A novel mitigation technique to eliminate the harmonic effects on over-current relays
title A novel mitigation technique to eliminate the harmonic effects on over-current relays
title_full A novel mitigation technique to eliminate the harmonic effects on over-current relays
title_fullStr A novel mitigation technique to eliminate the harmonic effects on over-current relays
title_full_unstemmed A novel mitigation technique to eliminate the harmonic effects on over-current relays
title_short A novel mitigation technique to eliminate the harmonic effects on over-current relays
title_sort novel mitigation technique to eliminate the harmonic effects on over-current relays
url http://hdl.handle.net/20.500.11937/93