Event-Related Potentials of Single-Sided Deaf Cochlear Implant Users: Using a Semantic Oddball Paradigm in Noise

Introduction: In individuals with single-sided deafness (SSD), who are characterised by profound hearing loss in one ear and normal hearing in the contralateral ear, binaural input is no longer present. A cochlear implant (CI) can restore functional hearing in the profoundly deaf ear, with previous...

Full description

Bibliographic Details
Main Authors: Voola, M., Wedekind, A., Nguyen, An, Marinovic, Welber, Rajan, G., Tavora-Vieira, D.
Format: Journal Article
Language:English
Published: 2023
Subjects:
Online Access:http://purl.org/au-research/grants/arc/DP180100394
http://hdl.handle.net/20.500.11937/91783
_version_ 1848765591127588864
author Voola, M.
Wedekind, A.
Nguyen, An
Marinovic, Welber
Rajan, G.
Tavora-Vieira, D.
author_facet Voola, M.
Wedekind, A.
Nguyen, An
Marinovic, Welber
Rajan, G.
Tavora-Vieira, D.
author_sort Voola, M.
building Curtin Institutional Repository
collection Online Access
description Introduction: In individuals with single-sided deafness (SSD), who are characterised by profound hearing loss in one ear and normal hearing in the contralateral ear, binaural input is no longer present. A cochlear implant (CI) can restore functional hearing in the profoundly deaf ear, with previous literature demonstrating improvements in speech-in-noise intelligibility with the CI. However, we currently have limited understanding of the neural processes involved (e.g., how the brain integrates the electrical signal produced by the CI with the acoustic signal produced by the normal hearing ear) and how modulation of these processes with a CI contributes to improved speech-in-noise intelligibility. Using a semantic oddball paradigm presented in the presence of background noise, this study aims to investigate how the provision of CI impacts speech-in-noise perception of SSD-CI users. Method: Task performance (reaction time, reaction time variability, target accuracy, subjective listening effort) and high density electroencephalography from twelve SSD-CI participants were recorded, while they completed a semantic acoustic oddball task. Reaction time was defined as the time taken for a participant to press the response button after stimulus onset. All participants completed the oddball task in three different free-field conditions with the speech and noise coming from different speakers. The three tasks were: (1) CI-On in background noise, (2) CI-Off in background noise, and (3) CI-On without background noise (Control). Task performance and electroencephalography data (N2N4 and P3b) were recorded for each condition. Speech in noise and sound localisation ability were also measured. Results: Reaction time was significantly different between all tasks with CI-On (M [SE] = 809 [39.9] ms) having faster RTs than CI-Off (M [SE] = 845 [39.9] ms) and Control (M [SE] = 785 [39.9] ms) being the fastest condition. The Control condition exhibited significantly shorter N2N4 and P3b area latency compared to the other two conditions. However, despite these differences noticed in RTs and area latency, we observed similar results between all three conditions for N2N4 and P3b difference area. Conclusion: The inconsistency between the behavioural and neural results suggests that EEG may not be a reliable measure of cognitive effort. This rationale is further supported by different explanations used in past studies to explain N2N4 and P3b effects. Future studies should look to alternative measures of auditory processing (e.g., pupillometry) to gain a deeper understanding of the underlying auditory processes that facilitate speech-in-noise intelligibility.
first_indexed 2025-11-14T11:37:41Z
format Journal Article
id curtin-20.500.11937-91783
institution Curtin University Malaysia
institution_category Local University
language eng
last_indexed 2025-11-14T11:37:41Z
publishDate 2023
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-917832023-06-06T04:14:04Z Event-Related Potentials of Single-Sided Deaf Cochlear Implant Users: Using a Semantic Oddball Paradigm in Noise Voola, M. Wedekind, A. Nguyen, An Marinovic, Welber Rajan, G. Tavora-Vieira, D. Cochlear implants Event-related potentials Oddball Single-sided deafness Introduction: In individuals with single-sided deafness (SSD), who are characterised by profound hearing loss in one ear and normal hearing in the contralateral ear, binaural input is no longer present. A cochlear implant (CI) can restore functional hearing in the profoundly deaf ear, with previous literature demonstrating improvements in speech-in-noise intelligibility with the CI. However, we currently have limited understanding of the neural processes involved (e.g., how the brain integrates the electrical signal produced by the CI with the acoustic signal produced by the normal hearing ear) and how modulation of these processes with a CI contributes to improved speech-in-noise intelligibility. Using a semantic oddball paradigm presented in the presence of background noise, this study aims to investigate how the provision of CI impacts speech-in-noise perception of SSD-CI users. Method: Task performance (reaction time, reaction time variability, target accuracy, subjective listening effort) and high density electroencephalography from twelve SSD-CI participants were recorded, while they completed a semantic acoustic oddball task. Reaction time was defined as the time taken for a participant to press the response button after stimulus onset. All participants completed the oddball task in three different free-field conditions with the speech and noise coming from different speakers. The three tasks were: (1) CI-On in background noise, (2) CI-Off in background noise, and (3) CI-On without background noise (Control). Task performance and electroencephalography data (N2N4 and P3b) were recorded for each condition. Speech in noise and sound localisation ability were also measured. Results: Reaction time was significantly different between all tasks with CI-On (M [SE] = 809 [39.9] ms) having faster RTs than CI-Off (M [SE] = 845 [39.9] ms) and Control (M [SE] = 785 [39.9] ms) being the fastest condition. The Control condition exhibited significantly shorter N2N4 and P3b area latency compared to the other two conditions. However, despite these differences noticed in RTs and area latency, we observed similar results between all three conditions for N2N4 and P3b difference area. Conclusion: The inconsistency between the behavioural and neural results suggests that EEG may not be a reliable measure of cognitive effort. This rationale is further supported by different explanations used in past studies to explain N2N4 and P3b effects. Future studies should look to alternative measures of auditory processing (e.g., pupillometry) to gain a deeper understanding of the underlying auditory processes that facilitate speech-in-noise intelligibility. 2023 Journal Article http://hdl.handle.net/20.500.11937/91783 10.1159/000529485 eng http://purl.org/au-research/grants/arc/DP180100394 http://creativecommons.org/licenses/by-nc/4.0/ fulltext
spellingShingle Cochlear implants
Event-related potentials
Oddball
Single-sided deafness
Voola, M.
Wedekind, A.
Nguyen, An
Marinovic, Welber
Rajan, G.
Tavora-Vieira, D.
Event-Related Potentials of Single-Sided Deaf Cochlear Implant Users: Using a Semantic Oddball Paradigm in Noise
title Event-Related Potentials of Single-Sided Deaf Cochlear Implant Users: Using a Semantic Oddball Paradigm in Noise
title_full Event-Related Potentials of Single-Sided Deaf Cochlear Implant Users: Using a Semantic Oddball Paradigm in Noise
title_fullStr Event-Related Potentials of Single-Sided Deaf Cochlear Implant Users: Using a Semantic Oddball Paradigm in Noise
title_full_unstemmed Event-Related Potentials of Single-Sided Deaf Cochlear Implant Users: Using a Semantic Oddball Paradigm in Noise
title_short Event-Related Potentials of Single-Sided Deaf Cochlear Implant Users: Using a Semantic Oddball Paradigm in Noise
title_sort event-related potentials of single-sided deaf cochlear implant users: using a semantic oddball paradigm in noise
topic Cochlear implants
Event-related potentials
Oddball
Single-sided deafness
url http://purl.org/au-research/grants/arc/DP180100394
http://hdl.handle.net/20.500.11937/91783