Utilizing an alternative composite material for effective copper(II) ion capturing from wastewater

The novel ligand based functionalized composite materials (CpMA) was fabricated using a highly porous silica and deployed as an effective materials for the effective monitoring and adsorption of copper (Cu(II)) ions from contaminated water. The application of CpMA was significantly intensified the m...

Full description

Bibliographic Details
Main Authors: Kubra, K.T., Salman, M.S., Hasan, M.N., Islam, A., Hasan, M.M., Awual, Rabiul
Format: Journal Article
Language:English
Published: ELSEVIER 2021
Subjects:
Online Access:http://hdl.handle.net/20.500.11937/88596
_version_ 1848765048965562368
author Kubra, K.T.
Salman, M.S.
Hasan, M.N.
Islam, A.
Hasan, M.M.
Awual, Rabiul
author_facet Kubra, K.T.
Salman, M.S.
Hasan, M.N.
Islam, A.
Hasan, M.M.
Awual, Rabiul
author_sort Kubra, K.T.
building Curtin Institutional Repository
collection Online Access
description The novel ligand based functionalized composite materials (CpMA) was fabricated using a highly porous silica and deployed as an effective materials for the effective monitoring and adsorption of copper (Cu(II)) ions from contaminated water. The application of CpMA was significantly intensified the monitoring and adsorption of Cu(II) ion at optimum experimental protocol. The organic ligand onto the mesoporous silica was the key factor for an efficient monitoring and adsorption of Cu(II) ion with optimum color formation. The effects of diverse experimental parameters such as solution pH, contact time, initial concentration, selectivity and sensitivity were measured systematically. The solution pH was played the key role for monitoring and adsorption and the present CpMA was worked well in acidic pH region at 3.50. The data clarified that the CpMA was able to detected with significant color formation even in the presence of ultra–trace Cu(II) ions, which was unique feature of the CpMA. The CpMA was offered simple, one–step monitoring procedure without the need of highly sophisticated apparatus. The low limit of detection was 0.36 µg/L based on the calibration curve. The CpMA was exhibited significant ion–selectivity toward the Cu(II) ion in the multi-mixture solution as environmental samples. The data revealed that the CpMA was selectively captured Cu(II) ions from binary and multi mixtures even in the presence of various competing ions. The adsorption isotherm was well described and the maximum adsorption capacity was as high as 189.35 mg/g. The elution of Cu(II) ions from the saturated CpMA was desorbed successfully with 0.30 M HCl. The regenerated material that remained maintained the high selectivity to Cu(II) ions and exhibited almost the same functionality as that of the original adsorbent. Therefore, the proposed CpMA offered a cost-effective and considered an alternative for effectively toxic Cu(II) ion capturing in real sample treatment.
first_indexed 2025-11-14T11:29:04Z
format Journal Article
id curtin-20.500.11937-88596
institution Curtin University Malaysia
institution_category Local University
language English
last_indexed 2025-11-14T11:29:04Z
publishDate 2021
publisher ELSEVIER
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-885962022-06-14T06:55:36Z Utilizing an alternative composite material for effective copper(II) ion capturing from wastewater Kubra, K.T. Salman, M.S. Hasan, M.N. Islam, A. Hasan, M.M. Awual, Rabiul Science & Technology Physical Sciences Chemistry, Physical Physics, Atomic, Molecular & Chemical Chemistry Physics Composite material Copper(II) ion Sensitive monitoring and adsorption Optical approach High efficiency IRON-OXIDE NANOPARTICLES CONJUGATE ADSORBENT AQUEOUS-SOLUTIONS REMOVAL EFFICIENT ADSORPTION SENSOR KINETICS LEAD NANOFILTRATION The novel ligand based functionalized composite materials (CpMA) was fabricated using a highly porous silica and deployed as an effective materials for the effective monitoring and adsorption of copper (Cu(II)) ions from contaminated water. The application of CpMA was significantly intensified the monitoring and adsorption of Cu(II) ion at optimum experimental protocol. The organic ligand onto the mesoporous silica was the key factor for an efficient monitoring and adsorption of Cu(II) ion with optimum color formation. The effects of diverse experimental parameters such as solution pH, contact time, initial concentration, selectivity and sensitivity were measured systematically. The solution pH was played the key role for monitoring and adsorption and the present CpMA was worked well in acidic pH region at 3.50. The data clarified that the CpMA was able to detected with significant color formation even in the presence of ultra–trace Cu(II) ions, which was unique feature of the CpMA. The CpMA was offered simple, one–step monitoring procedure without the need of highly sophisticated apparatus. The low limit of detection was 0.36 µg/L based on the calibration curve. The CpMA was exhibited significant ion–selectivity toward the Cu(II) ion in the multi-mixture solution as environmental samples. The data revealed that the CpMA was selectively captured Cu(II) ions from binary and multi mixtures even in the presence of various competing ions. The adsorption isotherm was well described and the maximum adsorption capacity was as high as 189.35 mg/g. The elution of Cu(II) ions from the saturated CpMA was desorbed successfully with 0.30 M HCl. The regenerated material that remained maintained the high selectivity to Cu(II) ions and exhibited almost the same functionality as that of the original adsorbent. Therefore, the proposed CpMA offered a cost-effective and considered an alternative for effectively toxic Cu(II) ion capturing in real sample treatment. 2021 Journal Article http://hdl.handle.net/20.500.11937/88596 10.1016/j.molliq.2021.116325 English ELSEVIER restricted
spellingShingle Science & Technology
Physical Sciences
Chemistry, Physical
Physics, Atomic, Molecular & Chemical
Chemistry
Physics
Composite material
Copper(II) ion
Sensitive monitoring and adsorption
Optical approach
High efficiency
IRON-OXIDE NANOPARTICLES
CONJUGATE ADSORBENT
AQUEOUS-SOLUTIONS
REMOVAL
EFFICIENT
ADSORPTION
SENSOR
KINETICS
LEAD
NANOFILTRATION
Kubra, K.T.
Salman, M.S.
Hasan, M.N.
Islam, A.
Hasan, M.M.
Awual, Rabiul
Utilizing an alternative composite material for effective copper(II) ion capturing from wastewater
title Utilizing an alternative composite material for effective copper(II) ion capturing from wastewater
title_full Utilizing an alternative composite material for effective copper(II) ion capturing from wastewater
title_fullStr Utilizing an alternative composite material for effective copper(II) ion capturing from wastewater
title_full_unstemmed Utilizing an alternative composite material for effective copper(II) ion capturing from wastewater
title_short Utilizing an alternative composite material for effective copper(II) ion capturing from wastewater
title_sort utilizing an alternative composite material for effective copper(ii) ion capturing from wastewater
topic Science & Technology
Physical Sciences
Chemistry, Physical
Physics, Atomic, Molecular & Chemical
Chemistry
Physics
Composite material
Copper(II) ion
Sensitive monitoring and adsorption
Optical approach
High efficiency
IRON-OXIDE NANOPARTICLES
CONJUGATE ADSORBENT
AQUEOUS-SOLUTIONS
REMOVAL
EFFICIENT
ADSORPTION
SENSOR
KINETICS
LEAD
NANOFILTRATION
url http://hdl.handle.net/20.500.11937/88596