Application of DSTATCOM for surplus power circulation in MV and LV distribution networks with single-phase distributed energy resources

Single-phase distributed energy resources (DERs), such as rooftop photovoltaic arrays, are usually installed based on the need and affordability of clients without any regard to the power demand of the connected phase of a three-phase system. It might so happen that the power generation in a particu...

Full description

Bibliographic Details
Main Authors: Shahnia, Farhad, Chandrasena, R., Ghosh, Arindam, Rajakaruna, Sumedha
Format: Journal Article
Published: Elsevier S.A. 2014
Subjects:
Online Access:http://hdl.handle.net/20.500.11937/8645
_version_ 1848745718446030848
author Shahnia, Farhad
Chandrasena, R.
Ghosh, Arindam
Rajakaruna, Sumedha
author_facet Shahnia, Farhad
Chandrasena, R.
Ghosh, Arindam
Rajakaruna, Sumedha
author_sort Shahnia, Farhad
building Curtin Institutional Repository
collection Online Access
description Single-phase distributed energy resources (DERs), such as rooftop photovoltaic arrays, are usually installed based on the need and affordability of clients without any regard to the power demand of the connected phase of a three-phase system. It might so happen that the power generation in a particular phase is more than its load demand. This may cause a reverse power flow in a particular phase, especially in a three-phase, four-wire distribution system. If now the load demand in the other two phases is more than their respective generations, then these two phases will see a forward power flow, while there will be a reverse power flow in the third phase. This will create severe unbalance in the upstream network. In this paper, a distribution static compensator (DSTATCOM) is used to circulate the excess generation from one phase to the others such that a set of balanced currents flow from or into the upstream network. Two different topologies of DSTATCOM are proposed in this paper for the low and medium voltage feeders. Two different power circulation strategies are developed for this purpose. Furthermore, a suitable feedback scheme is developed for each topology for power converter control. The performance of the proposed topologies and the control schemes for the DSTATCOM is evaluated through computer simulation studies using PSCAD/EMTDC.
first_indexed 2025-11-14T06:21:49Z
format Journal Article
id curtin-20.500.11937-8645
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T06:21:49Z
publishDate 2014
publisher Elsevier S.A.
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-86452019-02-19T05:35:29Z Application of DSTATCOM for surplus power circulation in MV and LV distribution networks with single-phase distributed energy resources Shahnia, Farhad Chandrasena, R. Ghosh, Arindam Rajakaruna, Sumedha Power circulation Single-phase DERs Distribution static compensator (DSTATCOM) Medium voltage feeders Low voltage feeders Distributed energy resource (DER) Single-phase distributed energy resources (DERs), such as rooftop photovoltaic arrays, are usually installed based on the need and affordability of clients without any regard to the power demand of the connected phase of a three-phase system. It might so happen that the power generation in a particular phase is more than its load demand. This may cause a reverse power flow in a particular phase, especially in a three-phase, four-wire distribution system. If now the load demand in the other two phases is more than their respective generations, then these two phases will see a forward power flow, while there will be a reverse power flow in the third phase. This will create severe unbalance in the upstream network. In this paper, a distribution static compensator (DSTATCOM) is used to circulate the excess generation from one phase to the others such that a set of balanced currents flow from or into the upstream network. Two different topologies of DSTATCOM are proposed in this paper for the low and medium voltage feeders. Two different power circulation strategies are developed for this purpose. Furthermore, a suitable feedback scheme is developed for each topology for power converter control. The performance of the proposed topologies and the control schemes for the DSTATCOM is evaluated through computer simulation studies using PSCAD/EMTDC. 2014 Journal Article http://hdl.handle.net/20.500.11937/8645 10.1016/j.epsr.2014.08.010 Elsevier S.A. fulltext
spellingShingle Power circulation
Single-phase DERs
Distribution static compensator (DSTATCOM)
Medium voltage feeders
Low voltage feeders
Distributed energy resource (DER)
Shahnia, Farhad
Chandrasena, R.
Ghosh, Arindam
Rajakaruna, Sumedha
Application of DSTATCOM for surplus power circulation in MV and LV distribution networks with single-phase distributed energy resources
title Application of DSTATCOM for surplus power circulation in MV and LV distribution networks with single-phase distributed energy resources
title_full Application of DSTATCOM for surplus power circulation in MV and LV distribution networks with single-phase distributed energy resources
title_fullStr Application of DSTATCOM for surplus power circulation in MV and LV distribution networks with single-phase distributed energy resources
title_full_unstemmed Application of DSTATCOM for surplus power circulation in MV and LV distribution networks with single-phase distributed energy resources
title_short Application of DSTATCOM for surplus power circulation in MV and LV distribution networks with single-phase distributed energy resources
title_sort application of dstatcom for surplus power circulation in mv and lv distribution networks with single-phase distributed energy resources
topic Power circulation
Single-phase DERs
Distribution static compensator (DSTATCOM)
Medium voltage feeders
Low voltage feeders
Distributed energy resource (DER)
url http://hdl.handle.net/20.500.11937/8645