Report on the Assessment of Thermal Insulator for RFoF Optical Link Cable

This report documents the selection process, characterisation and analysis of insulating solutions for surface-laid fibre optic cable from outdoor elements (ambient temperature fluctuations, wind and solar irradiation) in the field at the Murchison Radio-astronomy Observatory (MRO), in the context o...

Full description

Bibliographic Details
Main Author: Juswardy, Budi
Format: Report
Language:English
Published: 2019
Subjects:
Online Access:http://hdl.handle.net/20.500.11937/84208
_version_ 1848764623587639296
author Juswardy, Budi
author_facet Juswardy, Budi
author_sort Juswardy, Budi
building Curtin Institutional Repository
collection Online Access
description This report documents the selection process, characterisation and analysis of insulating solutions for surface-laid fibre optic cable from outdoor elements (ambient temperature fluctuations, wind and solar irradiation) in the field at the Murchison Radio-astronomy Observatory (MRO), in the context of SKA Bridging Array activity. The objective of the investigation is to find a solution that potentially mimic the response of underground cable burial (1.5 m) in reducing thermal effect on the fibre cable, to achieve reasonable phase stability of the transmitted RF signal, without actually trenching the cable. Worst-case estimates of the relative phase variation and the 24-hour relative phase drift of the installation (with and without the insulator) are provided, which are derived from actual cable measurements in the field, as well as calculated from characterisations of insulation sample in the lab. These estimates can then be used to predict the performance of future fibre cable installations for any given length, and to make an informed decision whether or not trenching the cable underground/ cable insulation is required, or weather cable performance is acceptable without any insulation. For SKA Bridging Array station with 200 m length fibre transmission distance, the worst-case estimate for the 24-hour relative RF phase drift between two RF links at 160 MHz would be in the order of: 1.5° (phase) for surface laid cable without insulation. Depending on the thickness of the insulator as evaluated, the relative phase drift is calculated to potentially be reduced down to approximately: 0.9° - 0.45° (phase) for insulator thickness between 25 mm – 75 mm, and the 50 mm wall thickness is found to be capable of providing damping and delayed temperature response, similar to the profile of cable buried 1.5 m underground.
first_indexed 2025-11-14T11:22:18Z
format Report
id curtin-20.500.11937-84208
institution Curtin University Malaysia
institution_category Local University
language English
last_indexed 2025-11-14T11:22:18Z
publishDate 2019
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-842082021-07-01T07:53:37Z Report on the Assessment of Thermal Insulator for RFoF Optical Link Cable Juswardy, Budi 0906 - Electrical and Electronic Engineering 1005 - Communications Technologies This report documents the selection process, characterisation and analysis of insulating solutions for surface-laid fibre optic cable from outdoor elements (ambient temperature fluctuations, wind and solar irradiation) in the field at the Murchison Radio-astronomy Observatory (MRO), in the context of SKA Bridging Array activity. The objective of the investigation is to find a solution that potentially mimic the response of underground cable burial (1.5 m) in reducing thermal effect on the fibre cable, to achieve reasonable phase stability of the transmitted RF signal, without actually trenching the cable. Worst-case estimates of the relative phase variation and the 24-hour relative phase drift of the installation (with and without the insulator) are provided, which are derived from actual cable measurements in the field, as well as calculated from characterisations of insulation sample in the lab. These estimates can then be used to predict the performance of future fibre cable installations for any given length, and to make an informed decision whether or not trenching the cable underground/ cable insulation is required, or weather cable performance is acceptable without any insulation. For SKA Bridging Array station with 200 m length fibre transmission distance, the worst-case estimate for the 24-hour relative RF phase drift between two RF links at 160 MHz would be in the order of: 1.5° (phase) for surface laid cable without insulation. Depending on the thickness of the insulator as evaluated, the relative phase drift is calculated to potentially be reduced down to approximately: 0.9° - 0.45° (phase) for insulator thickness between 25 mm – 75 mm, and the 50 mm wall thickness is found to be capable of providing damping and delayed temperature response, similar to the profile of cable buried 1.5 m underground. 2019 Report http://hdl.handle.net/20.500.11937/84208 English http://creativecommons.org/licenses/by/4.0/ fulltext
spellingShingle 0906 - Electrical and Electronic Engineering
1005 - Communications Technologies
Juswardy, Budi
Report on the Assessment of Thermal Insulator for RFoF Optical Link Cable
title Report on the Assessment of Thermal Insulator for RFoF Optical Link Cable
title_full Report on the Assessment of Thermal Insulator for RFoF Optical Link Cable
title_fullStr Report on the Assessment of Thermal Insulator for RFoF Optical Link Cable
title_full_unstemmed Report on the Assessment of Thermal Insulator for RFoF Optical Link Cable
title_short Report on the Assessment of Thermal Insulator for RFoF Optical Link Cable
title_sort report on the assessment of thermal insulator for rfof optical link cable
topic 0906 - Electrical and Electronic Engineering
1005 - Communications Technologies
url http://hdl.handle.net/20.500.11937/84208