Detection of sulfur dioxide at low parts-per-million concentrations using low-cost planar electrodes with ionic liquid electrolytes

© 2020 Elsevier B.V. Sulfur dioxide (SO2) is a toxic gas at low parts-per-million (ppm) concentrations, with a permissible exposure limit (PEL) of 2 ppm. Its detection is mandatory, particularly in the fields of occupational health and safety, and environmental pollution. In this work, ppm conce...

Full description

Bibliographic Details
Main Authors: Doblinger, Simon, Lee, Juni, Gurnah, Zoe, Silvester-Dean, Debbie
Format: Journal Article
Language:English
Published: 2020
Subjects:
Online Access:http://purl.org/au-research/grants/arc/FT170100315
http://hdl.handle.net/20.500.11937/79830
_version_ 1848764112664788992
author Doblinger, Simon
Lee, Juni
Gurnah, Zoe
Silvester-Dean, Debbie
author_facet Doblinger, Simon
Lee, Juni
Gurnah, Zoe
Silvester-Dean, Debbie
author_sort Doblinger, Simon
building Curtin Institutional Repository
collection Online Access
description © 2020 Elsevier B.V. Sulfur dioxide (SO2) is a toxic gas at low parts-per-million (ppm) concentrations, with a permissible exposure limit (PEL) of 2 ppm. Its detection is mandatory, particularly in the fields of occupational health and safety, and environmental pollution. In this work, ppm concentration detection of sulfur dioxide was performed in six room temperature ionic liquids (RTILs), as well as on two different electrode materials – platinum and gold – and with two different electrode geometries, i.e. macro thin-film electrodes (TFEs) and microarray thin-film electrodes (MATFEs). Calibration curves were established for 10–200 ppm SO2 using cyclic voltammetry to determine the optimum combination of RTIL, electrode surface and geometry for the sensing. The RTIL 1-butyl-1-methylpyrrolidinium bis(trifluoromethylsulfonium)imide ([C4mpyrr][NTf2]) with a platinum thin-film electrode was found to give the best response due to the relatively low viscosity of the RTIL combined with the high sensitivity and a clean blank response. On MATFEs, deposited sulfur particles – confirmed using scanning electron microscopy (SEM) coupled to an energy dispersive spectrometer – were found to passivate and block some of the microholes, leading to unstable long-term chronoamperometric responses. To the best of our knowledge, this is the first observation of sulfur deposition from SO2 reduction in aprotic ionic liquids. Consecutive additions of 2 ppm SO2 were studied in [C4mpyrr][NTf2] on a TFE using long-term chronoamperometry, showing excellent reproducibility upon successive additions. This demonstrates that small volumes of RTILs can be combined with miniaturized, low-cost TFEs and applied for the reliable and continuous monitoring of sulfur dioxide gas at concentrations lower than the permissible exposure limit of 2 ppm.
first_indexed 2025-11-14T11:14:11Z
format Journal Article
id curtin-20.500.11937-79830
institution Curtin University Malaysia
institution_category Local University
language eng
last_indexed 2025-11-14T11:14:11Z
publishDate 2020
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-798302021-05-25T05:16:24Z Detection of sulfur dioxide at low parts-per-million concentrations using low-cost planar electrodes with ionic liquid electrolytes Doblinger, Simon Lee, Juni Gurnah, Zoe Silvester-Dean, Debbie Cyclic voltammetry Gas sensing Long-term chronoamperometry Room temperature ionic liquids Sulfur dioxide Thin-film electrodes © 2020 Elsevier B.V. Sulfur dioxide (SO2) is a toxic gas at low parts-per-million (ppm) concentrations, with a permissible exposure limit (PEL) of 2 ppm. Its detection is mandatory, particularly in the fields of occupational health and safety, and environmental pollution. In this work, ppm concentration detection of sulfur dioxide was performed in six room temperature ionic liquids (RTILs), as well as on two different electrode materials – platinum and gold – and with two different electrode geometries, i.e. macro thin-film electrodes (TFEs) and microarray thin-film electrodes (MATFEs). Calibration curves were established for 10–200 ppm SO2 using cyclic voltammetry to determine the optimum combination of RTIL, electrode surface and geometry for the sensing. The RTIL 1-butyl-1-methylpyrrolidinium bis(trifluoromethylsulfonium)imide ([C4mpyrr][NTf2]) with a platinum thin-film electrode was found to give the best response due to the relatively low viscosity of the RTIL combined with the high sensitivity and a clean blank response. On MATFEs, deposited sulfur particles – confirmed using scanning electron microscopy (SEM) coupled to an energy dispersive spectrometer – were found to passivate and block some of the microholes, leading to unstable long-term chronoamperometric responses. To the best of our knowledge, this is the first observation of sulfur deposition from SO2 reduction in aprotic ionic liquids. Consecutive additions of 2 ppm SO2 were studied in [C4mpyrr][NTf2] on a TFE using long-term chronoamperometry, showing excellent reproducibility upon successive additions. This demonstrates that small volumes of RTILs can be combined with miniaturized, low-cost TFEs and applied for the reliable and continuous monitoring of sulfur dioxide gas at concentrations lower than the permissible exposure limit of 2 ppm. 2020 Journal Article http://hdl.handle.net/20.500.11937/79830 10.1016/j.aca.2020.05.037 eng http://purl.org/au-research/grants/arc/FT170100315 http://creativecommons.org/licenses/by-nc-nd/4.0/ fulltext
spellingShingle Cyclic voltammetry
Gas sensing
Long-term chronoamperometry
Room temperature ionic liquids
Sulfur dioxide
Thin-film electrodes
Doblinger, Simon
Lee, Juni
Gurnah, Zoe
Silvester-Dean, Debbie
Detection of sulfur dioxide at low parts-per-million concentrations using low-cost planar electrodes with ionic liquid electrolytes
title Detection of sulfur dioxide at low parts-per-million concentrations using low-cost planar electrodes with ionic liquid electrolytes
title_full Detection of sulfur dioxide at low parts-per-million concentrations using low-cost planar electrodes with ionic liquid electrolytes
title_fullStr Detection of sulfur dioxide at low parts-per-million concentrations using low-cost planar electrodes with ionic liquid electrolytes
title_full_unstemmed Detection of sulfur dioxide at low parts-per-million concentrations using low-cost planar electrodes with ionic liquid electrolytes
title_short Detection of sulfur dioxide at low parts-per-million concentrations using low-cost planar electrodes with ionic liquid electrolytes
title_sort detection of sulfur dioxide at low parts-per-million concentrations using low-cost planar electrodes with ionic liquid electrolytes
topic Cyclic voltammetry
Gas sensing
Long-term chronoamperometry
Room temperature ionic liquids
Sulfur dioxide
Thin-film electrodes
url http://purl.org/au-research/grants/arc/FT170100315
http://hdl.handle.net/20.500.11937/79830