Chlorine decay prediction in bulk water using the parallel second order model: An analytical solution development

All distributed drinking water receives some form of disinfection and a minimum disinfectant residual should be maintained at the customer tap. The most popular disinfectant is chlorine. Chlorine reacts with compounds in water and hence decays. Description of chlorine decay is often difficult, due t...

Full description

Bibliographic Details
Main Authors: Jabari Kohpaei, Ahmad, Sathasivan, Arumugam
Format: Journal Article
Published: Elsevier BV 2011
Subjects:
Online Access:http://hdl.handle.net/20.500.11937/7854
_version_ 1848745489258774528
author Jabari Kohpaei, Ahmad
Sathasivan, Arumugam
author_facet Jabari Kohpaei, Ahmad
Sathasivan, Arumugam
author_sort Jabari Kohpaei, Ahmad
building Curtin Institutional Repository
collection Online Access
description All distributed drinking water receives some form of disinfection and a minimum disinfectant residual should be maintained at the customer tap. The most popular disinfectant is chlorine. Chlorine reacts with compounds in water and hence decays. Description of chlorine decay is often difficult, due to a complex set of reactions and an initial fast reaction followed by a slower reaction. Before any attempt could be made to understand the decay characteristics in the distribution system, chlorine decay in bulk water has to be correctly described. The parallel second order reaction model was found to be one of the most suitable models for this purpose. However, widespread use of this model is hindered by its complexity, most importantly the non-existence of an analytical solution. In this paper, an analytical solution for this model was developed by initially assuming that the ratio (α) of slow and fast reaction rate coefficients is small. The estimated parameters and the chlorine residuals predicted by the numerical analysis and the proposed solution were compared for the chlorine decay data sets obtained from the literature as well as laboratory analysis. The results showed that the proposed analytical solution was very accurate for the prediction of chlorine decay behaviour in all samples.
first_indexed 2025-11-14T06:18:10Z
format Journal Article
id curtin-20.500.11937-7854
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T06:18:10Z
publishDate 2011
publisher Elsevier BV
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-78542017-09-13T15:53:52Z Chlorine decay prediction in bulk water using the parallel second order model: An analytical solution development Jabari Kohpaei, Ahmad Sathasivan, Arumugam Chlorine decay Analytical solution Accurate prediction Parallel second order kinetics Modelling All distributed drinking water receives some form of disinfection and a minimum disinfectant residual should be maintained at the customer tap. The most popular disinfectant is chlorine. Chlorine reacts with compounds in water and hence decays. Description of chlorine decay is often difficult, due to a complex set of reactions and an initial fast reaction followed by a slower reaction. Before any attempt could be made to understand the decay characteristics in the distribution system, chlorine decay in bulk water has to be correctly described. The parallel second order reaction model was found to be one of the most suitable models for this purpose. However, widespread use of this model is hindered by its complexity, most importantly the non-existence of an analytical solution. In this paper, an analytical solution for this model was developed by initially assuming that the ratio (α) of slow and fast reaction rate coefficients is small. The estimated parameters and the chlorine residuals predicted by the numerical analysis and the proposed solution were compared for the chlorine decay data sets obtained from the literature as well as laboratory analysis. The results showed that the proposed analytical solution was very accurate for the prediction of chlorine decay behaviour in all samples. 2011 Journal Article http://hdl.handle.net/20.500.11937/7854 10.1016/j.cej.2011.03.034 Elsevier BV restricted
spellingShingle Chlorine decay
Analytical solution
Accurate prediction
Parallel second order kinetics
Modelling
Jabari Kohpaei, Ahmad
Sathasivan, Arumugam
Chlorine decay prediction in bulk water using the parallel second order model: An analytical solution development
title Chlorine decay prediction in bulk water using the parallel second order model: An analytical solution development
title_full Chlorine decay prediction in bulk water using the parallel second order model: An analytical solution development
title_fullStr Chlorine decay prediction in bulk water using the parallel second order model: An analytical solution development
title_full_unstemmed Chlorine decay prediction in bulk water using the parallel second order model: An analytical solution development
title_short Chlorine decay prediction in bulk water using the parallel second order model: An analytical solution development
title_sort chlorine decay prediction in bulk water using the parallel second order model: an analytical solution development
topic Chlorine decay
Analytical solution
Accurate prediction
Parallel second order kinetics
Modelling
url http://hdl.handle.net/20.500.11937/7854