Experiments of Bubbling Fluidized Bed using ECVT Measurements

Gas-solid bubbling fluidized bed (BFB) is widely applied in industrial processes such as combustion, polymerization, cracking, etc. In BFB, gas-solid flow depends on formation of bubbles and its characteristics such as shape, size and frequency. This study estimates bubble size in a lab-scale BFB (F...

Full description

Bibliographic Details
Main Authors: Shah, Milin, Agrawal, Vaibhav, Shinde, Yogesh, Utikar, Ranjeet, Pareek, Vishnu
Format: Conference Paper
Published: 2017
Online Access:http://hdl.handle.net/20.500.11937/75933
_version_ 1848763587711991808
author Shah, Milin
Agrawal, Vaibhav
Shinde, Yogesh
Utikar, Ranjeet
Pareek, Vishnu
author_facet Shah, Milin
Agrawal, Vaibhav
Shinde, Yogesh
Utikar, Ranjeet
Pareek, Vishnu
author_sort Shah, Milin
building Curtin Institutional Repository
collection Online Access
description Gas-solid bubbling fluidized bed (BFB) is widely applied in industrial processes such as combustion, polymerization, cracking, etc. In BFB, gas-solid flow depends on formation of bubbles and its characteristics such as shape, size and frequency. This study estimates bubble size in a lab-scale BFB (Figure-1a) at three different fluidization velocity using non-invasive measurements from electrical capacitance volume tomography (ECVT). The experimented bed is a cylindrical column of 20 cm diameter and 120 cm height. The measurement section covered by ECVT sensors is 35 cm height and placed at 5 cm above the distributor. Typically, ECVT or any other tomographic technique provides volume fraction distribution in the test section at a resolution that depends primarily on sensor configurations and reconstruction algorithm. In this experiments, the ECVT sensor has 24 electrodes (Figure-1a) which gives 3D image having 20 × 20 × 20 voxels. At such low resolution of the ECVT, estimation of bubble size strongly depends on a threshold solids volume fraction that is used to distinguish the bubble from the dense phase in post-processing of data. Previous studies used a single threshold value to postprocess the captured data. This study finds that use of a single threshold value to post-process all captured data leads to inaccurate estimation of bubble diameter and sometimes can’t even capture smaller bubbles. This has been a major drawback of previous studies on estimation of bubble size using ECVT. In this work, we conducted a series of calibration experiments of static bed with a known size beaker at the centre of the bed. The calibration experiments show that lower values of the threshold underestimate the beaker size, whereas higher value of threshold overestimate the size. It is found that higher value of threshold should be used to capture the small size beakers. The measurements from these calibration experiments are further used to develop an iterative algorithm to determine optimum threshold value for a given ECVT image. The developed algorithm is used to estimate bubble size under dynamic fluidization. It is found that variable thresholding from the iterative algorithm is able to capture bubbles as small as 2.3 cm in 20 cm diameter bed and also gave estimated bubble size consistent with those calculated from empirical correlations with ±20% error.
first_indexed 2025-11-14T11:05:50Z
format Conference Paper
id curtin-20.500.11937-75933
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T11:05:50Z
publishDate 2017
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-759332019-07-09T01:55:58Z Experiments of Bubbling Fluidized Bed using ECVT Measurements Shah, Milin Agrawal, Vaibhav Shinde, Yogesh Utikar, Ranjeet Pareek, Vishnu Gas-solid bubbling fluidized bed (BFB) is widely applied in industrial processes such as combustion, polymerization, cracking, etc. In BFB, gas-solid flow depends on formation of bubbles and its characteristics such as shape, size and frequency. This study estimates bubble size in a lab-scale BFB (Figure-1a) at three different fluidization velocity using non-invasive measurements from electrical capacitance volume tomography (ECVT). The experimented bed is a cylindrical column of 20 cm diameter and 120 cm height. The measurement section covered by ECVT sensors is 35 cm height and placed at 5 cm above the distributor. Typically, ECVT or any other tomographic technique provides volume fraction distribution in the test section at a resolution that depends primarily on sensor configurations and reconstruction algorithm. In this experiments, the ECVT sensor has 24 electrodes (Figure-1a) which gives 3D image having 20 × 20 × 20 voxels. At such low resolution of the ECVT, estimation of bubble size strongly depends on a threshold solids volume fraction that is used to distinguish the bubble from the dense phase in post-processing of data. Previous studies used a single threshold value to postprocess the captured data. This study finds that use of a single threshold value to post-process all captured data leads to inaccurate estimation of bubble diameter and sometimes can’t even capture smaller bubbles. This has been a major drawback of previous studies on estimation of bubble size using ECVT. In this work, we conducted a series of calibration experiments of static bed with a known size beaker at the centre of the bed. The calibration experiments show that lower values of the threshold underestimate the beaker size, whereas higher value of threshold overestimate the size. It is found that higher value of threshold should be used to capture the small size beakers. The measurements from these calibration experiments are further used to develop an iterative algorithm to determine optimum threshold value for a given ECVT image. The developed algorithm is used to estimate bubble size under dynamic fluidization. It is found that variable thresholding from the iterative algorithm is able to capture bubbles as small as 2.3 cm in 20 cm diameter bed and also gave estimated bubble size consistent with those calculated from empirical correlations with ±20% error. 2017 Conference Paper http://hdl.handle.net/20.500.11937/75933 restricted
spellingShingle Shah, Milin
Agrawal, Vaibhav
Shinde, Yogesh
Utikar, Ranjeet
Pareek, Vishnu
Experiments of Bubbling Fluidized Bed using ECVT Measurements
title Experiments of Bubbling Fluidized Bed using ECVT Measurements
title_full Experiments of Bubbling Fluidized Bed using ECVT Measurements
title_fullStr Experiments of Bubbling Fluidized Bed using ECVT Measurements
title_full_unstemmed Experiments of Bubbling Fluidized Bed using ECVT Measurements
title_short Experiments of Bubbling Fluidized Bed using ECVT Measurements
title_sort experiments of bubbling fluidized bed using ecvt measurements
url http://hdl.handle.net/20.500.11937/75933