Application of STATCOM to improve the LVRT of DFIG during RSC Fire-through Fault

The use of doubly fed induction generators (DFIGs) in large wind energy conversion systems (WECS) has significantly increased during the last few years. The DFIG is interfaced to the AC network through a grid side voltage source converter (GSC) and a rotor side voltage source converter (RSC) to enab...

Full description

Bibliographic Details
Main Authors: Abdou, A., Abu-Siada, Ahmed, Pota, H.
Other Authors: Mochamad Ashari
Format: Conference Paper
Published: Institut Teknologi Sepuluh Nopember (ITS) 2012
Online Access:http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6360266
http://hdl.handle.net/20.500.11937/7524
_version_ 1848745393117986816
author Abdou, A.
Abu-Siada, Ahmed
Pota, H.
author2 Mochamad Ashari
author_facet Mochamad Ashari
Abdou, A.
Abu-Siada, Ahmed
Pota, H.
author_sort Abdou, A.
building Curtin Institutional Repository
collection Online Access
description The use of doubly fed induction generators (DFIGs) in large wind energy conversion systems (WECS) has significantly increased during the last few years. The DFIG is interfaced to the AC network through a grid side voltage source converter (GSC) and a rotor side voltage source converter (RSC) to enable the variable speed operation of the wind turbine. Moreover, it provides reactive power support to the AC grid during disturbances. The sensitivity of DFIGs to external faults has motivated researchers to investigate the impact of various grid disturbances, such as voltage sag and short circuit faults, on the low voltage ride through (LVRT) capability of DFIGs. However, no attempts have been made to investigate the impact of converter internal faults on the LVRT of the DFIG-based WECS. In this paper, the impact of a fire-through fault when it occurs in the RSC on the DC-capacitor voltage, rotor current, and the LVRT capability of the DFIG is investigated. A STATCOM controller to mitigate the effects of this fault is proposed. The DFIG compliance with various recently released LVRT grid codes under the fire-through fault with and without the STATCOM is examined and compared. Simulation results indicate that fire-through fault has a severe impact on the DFIG voltage profile and the proposed controller is capable of bringing the voltage profile at the point of common coupling (PCC) to the nominal steady state level.
first_indexed 2025-11-14T06:16:38Z
format Conference Paper
id curtin-20.500.11937-7524
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T06:16:38Z
publishDate 2012
publisher Institut Teknologi Sepuluh Nopember (ITS)
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-75242017-01-30T11:00:23Z Application of STATCOM to improve the LVRT of DFIG during RSC Fire-through Fault Abdou, A. Abu-Siada, Ahmed Pota, H. Mochamad Ashari The use of doubly fed induction generators (DFIGs) in large wind energy conversion systems (WECS) has significantly increased during the last few years. The DFIG is interfaced to the AC network through a grid side voltage source converter (GSC) and a rotor side voltage source converter (RSC) to enable the variable speed operation of the wind turbine. Moreover, it provides reactive power support to the AC grid during disturbances. The sensitivity of DFIGs to external faults has motivated researchers to investigate the impact of various grid disturbances, such as voltage sag and short circuit faults, on the low voltage ride through (LVRT) capability of DFIGs. However, no attempts have been made to investigate the impact of converter internal faults on the LVRT of the DFIG-based WECS. In this paper, the impact of a fire-through fault when it occurs in the RSC on the DC-capacitor voltage, rotor current, and the LVRT capability of the DFIG is investigated. A STATCOM controller to mitigate the effects of this fault is proposed. The DFIG compliance with various recently released LVRT grid codes under the fire-through fault with and without the STATCOM is examined and compared. Simulation results indicate that fire-through fault has a severe impact on the DFIG voltage profile and the proposed controller is capable of bringing the voltage profile at the point of common coupling (PCC) to the nominal steady state level. 2012 Conference Paper http://hdl.handle.net/20.500.11937/7524 http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6360266 Institut Teknologi Sepuluh Nopember (ITS) fulltext
spellingShingle Abdou, A.
Abu-Siada, Ahmed
Pota, H.
Application of STATCOM to improve the LVRT of DFIG during RSC Fire-through Fault
title Application of STATCOM to improve the LVRT of DFIG during RSC Fire-through Fault
title_full Application of STATCOM to improve the LVRT of DFIG during RSC Fire-through Fault
title_fullStr Application of STATCOM to improve the LVRT of DFIG during RSC Fire-through Fault
title_full_unstemmed Application of STATCOM to improve the LVRT of DFIG during RSC Fire-through Fault
title_short Application of STATCOM to improve the LVRT of DFIG during RSC Fire-through Fault
title_sort application of statcom to improve the lvrt of dfig during rsc fire-through fault
url http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6360266
http://hdl.handle.net/20.500.11937/7524