Partial Discharge Analysis on-site in Various High Voltage Apparatus

© 2018 IEEE. Partial discharge (PD) analysis is one of the most reliable non-destructive tests to clarify the quality of the insulation and to evaluate the life expectancy of high voltage (HV) devices. To perform PD testing and analysis accurately, it is important to select the correct method with r...

Full description

Bibliographic Details
Main Authors: Kim, D., Abu-Siada, Ahmed
Format: Conference Paper
Published: 2018
Online Access:http://hdl.handle.net/20.500.11937/74239
_version_ 1848763217990385664
author Kim, D.
Abu-Siada, Ahmed
author_facet Kim, D.
Abu-Siada, Ahmed
author_sort Kim, D.
building Curtin Institutional Repository
collection Online Access
description © 2018 IEEE. Partial discharge (PD) analysis is one of the most reliable non-destructive tests to clarify the quality of the insulation and to evaluate the life expectancy of high voltage (HV) devices. To perform PD testing and analysis accurately, it is important to select the correct method with respect to various sorts of the specimen. This paper aims at supporting HV engineers and asset managers to select a correct PD method and to make a clear maintenance plan. Also, this paper presents the difference between on and off PD analysis techniques, and the proper PD testing for rotating machines, switchgears and power cables with a case study and practical suggestions.
first_indexed 2025-11-14T10:59:58Z
format Conference Paper
id curtin-20.500.11937-74239
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T10:59:58Z
publishDate 2018
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-742392019-02-19T04:26:41Z Partial Discharge Analysis on-site in Various High Voltage Apparatus Kim, D. Abu-Siada, Ahmed © 2018 IEEE. Partial discharge (PD) analysis is one of the most reliable non-destructive tests to clarify the quality of the insulation and to evaluate the life expectancy of high voltage (HV) devices. To perform PD testing and analysis accurately, it is important to select the correct method with respect to various sorts of the specimen. This paper aims at supporting HV engineers and asset managers to select a correct PD method and to make a clear maintenance plan. Also, this paper presents the difference between on and off PD analysis techniques, and the proper PD testing for rotating machines, switchgears and power cables with a case study and practical suggestions. 2018 Conference Paper http://hdl.handle.net/20.500.11937/74239 10.1109/CMD.2018.8535987 restricted
spellingShingle Kim, D.
Abu-Siada, Ahmed
Partial Discharge Analysis on-site in Various High Voltage Apparatus
title Partial Discharge Analysis on-site in Various High Voltage Apparatus
title_full Partial Discharge Analysis on-site in Various High Voltage Apparatus
title_fullStr Partial Discharge Analysis on-site in Various High Voltage Apparatus
title_full_unstemmed Partial Discharge Analysis on-site in Various High Voltage Apparatus
title_short Partial Discharge Analysis on-site in Various High Voltage Apparatus
title_sort partial discharge analysis on-site in various high voltage apparatus
url http://hdl.handle.net/20.500.11937/74239