Validity and reliability of a freehand 3D ultrasound system for the determination of triceps surae muscle volume in children with cerebral palsy

This study assessed the validity, intra-rater and inter-rater reliability of segmentation of in vivo medial gastrocnemius (MG), lateral gastrocnemius (LG) and soleus (SOL) muscle volume measurement using a single sweep freehand 3D ultrasound (3DUS) in children with cerebral palsy (CP). The MG, LG an...

Full description

Bibliographic Details
Main Authors: Barber, L., Alexander, C., Shipman, P., Boyd, Roslyn, Reid, S., Elliott, Catherine
Format: Journal Article
Published: Wiley Blackwell Publishing Ltd 2018
Online Access:http://hdl.handle.net/20.500.11937/74164
_version_ 1848763197501210624
author Barber, L.
Alexander, C.
Shipman, P.
Boyd, Roslyn
Reid, S.
Elliott, Catherine
author_facet Barber, L.
Alexander, C.
Shipman, P.
Boyd, Roslyn
Reid, S.
Elliott, Catherine
author_sort Barber, L.
building Curtin Institutional Repository
collection Online Access
description This study assessed the validity, intra-rater and inter-rater reliability of segmentation of in vivo medial gastrocnemius (MG), lateral gastrocnemius (LG) and soleus (SOL) muscle volume measurement using a single sweep freehand 3D ultrasound (3DUS) in children with cerebral palsy (CP). The MG, LG and SOL of both limbs of 18 children with CP (age 8 years 4 months ± 1 year 10 months, 11 males, unilateral CP = 9, bilateral CP = 9, Gross Motor Functional Classification System I = 11, II = 7) were scanned using freehand 3DUS and magnetic resonance imaging (MRI). All freehand 3DUS and MRI images were segmented and volumes rendered by two raters. Validity was assessed using limits of agreement method. Intra-rater and inter-rater reliability was assessed using intra-class correlation (ICC), coefficient of variance (CV) and minimal detectable change (MDC). Freehand 3DUS overestimated muscle volume of the MG and LG by < 0.3 mL (1%) and underestimated SOL by < 1.3 mL (1.5%) compared with MRI. ICCs for intra-rater reliability of the segmentation process for the freehand 3DUS system and MRI for muscle volume were > 0.98 and 0.99, respectively, for all muscles. ICCs for inter-rater reliability of the segmentation process for freehand 3DUS and MRI volumes were > 0.96 and 0.98, respectively, for all muscles. MDCs for single rater freehand 3DUS and MRI were < 4.0 mL (14%) and 3.2 mL (11%), respectively, in all muscles. Freehand 3DUS is a valid and reliable method for the measurement of lower leg muscle volume that can be measured with a single sweep in children with CP in vivo. It can be used as an alternative to MRI for the detection of clinically relevant changes in calf muscle volume as the result of growth and interventions.
first_indexed 2025-11-14T10:59:38Z
format Journal Article
id curtin-20.500.11937-74164
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T10:59:38Z
publishDate 2018
publisher Wiley Blackwell Publishing Ltd
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-741642019-05-01T02:59:21Z Validity and reliability of a freehand 3D ultrasound system for the determination of triceps surae muscle volume in children with cerebral palsy Barber, L. Alexander, C. Shipman, P. Boyd, Roslyn Reid, S. Elliott, Catherine This study assessed the validity, intra-rater and inter-rater reliability of segmentation of in vivo medial gastrocnemius (MG), lateral gastrocnemius (LG) and soleus (SOL) muscle volume measurement using a single sweep freehand 3D ultrasound (3DUS) in children with cerebral palsy (CP). The MG, LG and SOL of both limbs of 18 children with CP (age 8 years 4 months ± 1 year 10 months, 11 males, unilateral CP = 9, bilateral CP = 9, Gross Motor Functional Classification System I = 11, II = 7) were scanned using freehand 3DUS and magnetic resonance imaging (MRI). All freehand 3DUS and MRI images were segmented and volumes rendered by two raters. Validity was assessed using limits of agreement method. Intra-rater and inter-rater reliability was assessed using intra-class correlation (ICC), coefficient of variance (CV) and minimal detectable change (MDC). Freehand 3DUS overestimated muscle volume of the MG and LG by < 0.3 mL (1%) and underestimated SOL by < 1.3 mL (1.5%) compared with MRI. ICCs for intra-rater reliability of the segmentation process for the freehand 3DUS system and MRI for muscle volume were > 0.98 and 0.99, respectively, for all muscles. ICCs for inter-rater reliability of the segmentation process for freehand 3DUS and MRI volumes were > 0.96 and 0.98, respectively, for all muscles. MDCs for single rater freehand 3DUS and MRI were < 4.0 mL (14%) and 3.2 mL (11%), respectively, in all muscles. Freehand 3DUS is a valid and reliable method for the measurement of lower leg muscle volume that can be measured with a single sweep in children with CP in vivo. It can be used as an alternative to MRI for the detection of clinically relevant changes in calf muscle volume as the result of growth and interventions. 2018 Journal Article http://hdl.handle.net/20.500.11937/74164 10.1111/joa.12927 Wiley Blackwell Publishing Ltd restricted
spellingShingle Barber, L.
Alexander, C.
Shipman, P.
Boyd, Roslyn
Reid, S.
Elliott, Catherine
Validity and reliability of a freehand 3D ultrasound system for the determination of triceps surae muscle volume in children with cerebral palsy
title Validity and reliability of a freehand 3D ultrasound system for the determination of triceps surae muscle volume in children with cerebral palsy
title_full Validity and reliability of a freehand 3D ultrasound system for the determination of triceps surae muscle volume in children with cerebral palsy
title_fullStr Validity and reliability of a freehand 3D ultrasound system for the determination of triceps surae muscle volume in children with cerebral palsy
title_full_unstemmed Validity and reliability of a freehand 3D ultrasound system for the determination of triceps surae muscle volume in children with cerebral palsy
title_short Validity and reliability of a freehand 3D ultrasound system for the determination of triceps surae muscle volume in children with cerebral palsy
title_sort validity and reliability of a freehand 3d ultrasound system for the determination of triceps surae muscle volume in children with cerebral palsy
url http://hdl.handle.net/20.500.11937/74164