How to deal with impulsive noise in OFDM-based PLC: A survey
© 2017 IEEE. Power-line communications (PLC) is a favorable technology for smart grid systems due to the wide penetration of power-line infrastructure. Broadband PLC (BB-PLC) is required for future smart grid applications as the data traffic may be high. However, BB-PLC performance is degraded by th...
| Main Authors: | , , , |
|---|---|
| Format: | Conference Paper |
| Published: |
2018
|
| Online Access: | http://hdl.handle.net/20.500.11937/72507 |
| _version_ | 1848762768569663488 |
|---|---|
| author | Mariyam, P. Juwono, Filbert Hilman Pamungkasari, P. Gunawan, D. |
| author_facet | Mariyam, P. Juwono, Filbert Hilman Pamungkasari, P. Gunawan, D. |
| author_sort | Mariyam, P. |
| building | Curtin Institutional Repository |
| collection | Online Access |
| description | © 2017 IEEE. Power-line communications (PLC) is a favorable technology for smart grid systems due to the wide penetration of power-line infrastructure. Broadband PLC (BB-PLC) is required for future smart grid applications as the data traffic may be high. However, BB-PLC performance is degraded by the occurrence of impulsive noise. Some methods have been proposed to reduce the effect of the impulsive noise in BB-PLC. In the liteature, the classification of impulsive noise mitigation methods has not been available. In this paper, we aim to develop a classification of the impulsive mitigation methods and provide a brief discussion of each method. The classification is useful as a further reference of designing BB-PLC systems under impulsive noise environment. |
| first_indexed | 2025-11-14T10:52:49Z |
| format | Conference Paper |
| id | curtin-20.500.11937-72507 |
| institution | Curtin University Malaysia |
| institution_category | Local University |
| last_indexed | 2025-11-14T10:52:49Z |
| publishDate | 2018 |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | curtin-20.500.11937-725072018-12-13T09:31:55Z How to deal with impulsive noise in OFDM-based PLC: A survey Mariyam, P. Juwono, Filbert Hilman Pamungkasari, P. Gunawan, D. © 2017 IEEE. Power-line communications (PLC) is a favorable technology for smart grid systems due to the wide penetration of power-line infrastructure. Broadband PLC (BB-PLC) is required for future smart grid applications as the data traffic may be high. However, BB-PLC performance is degraded by the occurrence of impulsive noise. Some methods have been proposed to reduce the effect of the impulsive noise in BB-PLC. In the liteature, the classification of impulsive noise mitigation methods has not been available. In this paper, we aim to develop a classification of the impulsive mitigation methods and provide a brief discussion of each method. The classification is useful as a further reference of designing BB-PLC systems under impulsive noise environment. 2018 Conference Paper http://hdl.handle.net/20.500.11937/72507 10.1109/ICELTICS.2017.8253260 restricted |
| spellingShingle | Mariyam, P. Juwono, Filbert Hilman Pamungkasari, P. Gunawan, D. How to deal with impulsive noise in OFDM-based PLC: A survey |
| title | How to deal with impulsive noise in OFDM-based PLC: A survey |
| title_full | How to deal with impulsive noise in OFDM-based PLC: A survey |
| title_fullStr | How to deal with impulsive noise in OFDM-based PLC: A survey |
| title_full_unstemmed | How to deal with impulsive noise in OFDM-based PLC: A survey |
| title_short | How to deal with impulsive noise in OFDM-based PLC: A survey |
| title_sort | how to deal with impulsive noise in ofdm-based plc: a survey |
| url | http://hdl.handle.net/20.500.11937/72507 |