Comparison of optimal designs of steel portal frames including topological asymmetry considering rolled, fabricated and tapered sections

A structural design optimisation has been carried out to allow for asymmetry and fully tapered portal frames. The additional weight of an asymmetric structural shape was found to be on average 5–13% with additional photovoltaic (PV) loading having a negligible effect on the optimum design. It was al...

Full description

Bibliographic Details
Main Authors: McKinstray, R., Lim, J., Tanyimboh, T., Phan, D., Sha, W., Phan, Thanh Duoc
Format: Journal Article
Published: Pergamon 2016
Online Access:http://hdl.handle.net/20.500.11937/7189
Description
Summary:A structural design optimisation has been carried out to allow for asymmetry and fully tapered portal frames. The additional weight of an asymmetric structural shape was found to be on average 5–13% with additional photovoltaic (PV) loading having a negligible effect on the optimum design. It was also shown that fabricated and tapered frames achieved an average percentage weight reduction of 9% and 11%, respectively, as compared to comparable hot-rolled steel frames. When the deflection limits recommended by the Steel Construction Institute were used, frames were shown to be deflection controlled with industrial limits yielding up to 40% saving.