Optimal sizing, siting and operation of custom power devices with STATCOM and APLC functions for real-time reactive power and network voltage quality control of smart grid

© 2010-2012 IEEE. A new custom power device (CPD) is introduced for real-time control of reactive power and improving the overall network voltage quality of smart grid (SG) at fundamental and harmonic frequencies, respectively. The idea is to take advantage of the online smart meter data transmitted...

Full description

Bibliographic Details
Main Authors: Moghbel, M., Masoum, Mohammad Sherkat, Fereidouni, A., Deilami, Sara
Format: Journal Article
Published: The Institute of Electrical and Electronics Engineers, Inc 2018
Online Access:http://hdl.handle.net/20.500.11937/71617
_version_ 1848762527870091264
author Moghbel, M.
Masoum, Mohammad Sherkat
Fereidouni, A.
Deilami, Sara
author_facet Moghbel, M.
Masoum, Mohammad Sherkat
Fereidouni, A.
Deilami, Sara
author_sort Moghbel, M.
building Curtin Institutional Repository
collection Online Access
description © 2010-2012 IEEE. A new custom power device (CPD) is introduced for real-time control of reactive power and improving the overall network voltage quality of smart grid (SG) at fundamental and harmonic frequencies, respectively. The idea is to take advantage of the online smart meter data transmitted from each bus to the SG central control to concurrently perform the static synchronous compensator and the active power line conditioner operations by optimal compensations of fundamental reactive power and harmonic currents at selected optimal buses. The proposed strategy involves two particle swarm optimization algorithms. The first algorithm is implemented for the worse operating condition to determine the optimal locations and sizes of CPDs while the second algorithm relies on smart meter information to continuously compute fundamental and harmonic reference currents for real-time operation and control of the allocated CPDs. The objective functions are cost minimizations associated with bus voltage regulations, network total harmonic distortions voltage and custom device sizing while the constraints include upper limits for CPD sizes, fundamental, and harmonic bus voltages. Detailed simulations are performed in MATLAB/Simulink to evaluate the performances of allocated CPDs in controlling the reactive power and voltage quality of a distorted 15-bus SG with six nonlinear loads according to the IEEE-519 standard.
first_indexed 2025-11-14T10:48:59Z
format Journal Article
id curtin-20.500.11937-71617
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T10:48:59Z
publishDate 2018
publisher The Institute of Electrical and Electronics Engineers, Inc
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-716172018-12-13T09:32:39Z Optimal sizing, siting and operation of custom power devices with STATCOM and APLC functions for real-time reactive power and network voltage quality control of smart grid Moghbel, M. Masoum, Mohammad Sherkat Fereidouni, A. Deilami, Sara © 2010-2012 IEEE. A new custom power device (CPD) is introduced for real-time control of reactive power and improving the overall network voltage quality of smart grid (SG) at fundamental and harmonic frequencies, respectively. The idea is to take advantage of the online smart meter data transmitted from each bus to the SG central control to concurrently perform the static synchronous compensator and the active power line conditioner operations by optimal compensations of fundamental reactive power and harmonic currents at selected optimal buses. The proposed strategy involves two particle swarm optimization algorithms. The first algorithm is implemented for the worse operating condition to determine the optimal locations and sizes of CPDs while the second algorithm relies on smart meter information to continuously compute fundamental and harmonic reference currents for real-time operation and control of the allocated CPDs. The objective functions are cost minimizations associated with bus voltage regulations, network total harmonic distortions voltage and custom device sizing while the constraints include upper limits for CPD sizes, fundamental, and harmonic bus voltages. Detailed simulations are performed in MATLAB/Simulink to evaluate the performances of allocated CPDs in controlling the reactive power and voltage quality of a distorted 15-bus SG with six nonlinear loads according to the IEEE-519 standard. 2018 Journal Article http://hdl.handle.net/20.500.11937/71617 10.1109/TSG.2017.2690681 The Institute of Electrical and Electronics Engineers, Inc restricted
spellingShingle Moghbel, M.
Masoum, Mohammad Sherkat
Fereidouni, A.
Deilami, Sara
Optimal sizing, siting and operation of custom power devices with STATCOM and APLC functions for real-time reactive power and network voltage quality control of smart grid
title Optimal sizing, siting and operation of custom power devices with STATCOM and APLC functions for real-time reactive power and network voltage quality control of smart grid
title_full Optimal sizing, siting and operation of custom power devices with STATCOM and APLC functions for real-time reactive power and network voltage quality control of smart grid
title_fullStr Optimal sizing, siting and operation of custom power devices with STATCOM and APLC functions for real-time reactive power and network voltage quality control of smart grid
title_full_unstemmed Optimal sizing, siting and operation of custom power devices with STATCOM and APLC functions for real-time reactive power and network voltage quality control of smart grid
title_short Optimal sizing, siting and operation of custom power devices with STATCOM and APLC functions for real-time reactive power and network voltage quality control of smart grid
title_sort optimal sizing, siting and operation of custom power devices with statcom and aplc functions for real-time reactive power and network voltage quality control of smart grid
url http://hdl.handle.net/20.500.11937/71617