Top-of-the-line corrosion control by continuous chemical treatment
Top-of-the-Line (TOL) corrosion was investigated under different carbon dioxide partial pressures, acetic acid concentrations, and temperatures in order to understand the impact of these different parameters on TOL corrosion.16 generic amines were tested as possible volatile corrosion inhibitor (VCI...
| Main Author: | |
|---|---|
| Format: | Thesis |
| Language: | English |
| Published: |
Curtin University
2012
|
| Online Access: | http://hdl.handle.net/20.500.11937/703 |
| _version_ | 1848743455818252288 |
|---|---|
| author | Oehler, Mike C. |
| author_facet | Oehler, Mike C. |
| author_sort | Oehler, Mike C. |
| building | Curtin Institutional Repository |
| collection | Online Access |
| description | Top-of-the-Line (TOL) corrosion was investigated under different carbon dioxide partial pressures, acetic acid concentrations, and temperatures in order to understand the impact of these different parameters on TOL corrosion.16 generic amines were tested as possible volatile corrosion inhibitor (VCI) candidates in a variety of TOL corrosion test set-ups. Properties of a working TOL corrosion inhibitor were identified and TOL corrosion laboratory test methods were improved. |
| first_indexed | 2025-11-14T05:45:51Z |
| format | Thesis |
| id | curtin-20.500.11937-703 |
| institution | Curtin University Malaysia |
| institution_category | Local University |
| language | English |
| last_indexed | 2025-11-14T05:45:51Z |
| publishDate | 2012 |
| publisher | Curtin University |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | curtin-20.500.11937-7032017-02-20T06:41:33Z Top-of-the-line corrosion control by continuous chemical treatment Oehler, Mike C. Top-of-the-Line (TOL) corrosion was investigated under different carbon dioxide partial pressures, acetic acid concentrations, and temperatures in order to understand the impact of these different parameters on TOL corrosion.16 generic amines were tested as possible volatile corrosion inhibitor (VCI) candidates in a variety of TOL corrosion test set-ups. Properties of a working TOL corrosion inhibitor were identified and TOL corrosion laboratory test methods were improved. 2012 Thesis http://hdl.handle.net/20.500.11937/703 en Curtin University fulltext |
| spellingShingle | Oehler, Mike C. Top-of-the-line corrosion control by continuous chemical treatment |
| title | Top-of-the-line corrosion control by continuous chemical treatment |
| title_full | Top-of-the-line corrosion control by continuous chemical treatment |
| title_fullStr | Top-of-the-line corrosion control by continuous chemical treatment |
| title_full_unstemmed | Top-of-the-line corrosion control by continuous chemical treatment |
| title_short | Top-of-the-line corrosion control by continuous chemical treatment |
| title_sort | top-of-the-line corrosion control by continuous chemical treatment |