Top-of-the-line corrosion control by continuous chemical treatment

Top-of-the-Line (TOL) corrosion was investigated under different carbon dioxide partial pressures, acetic acid concentrations, and temperatures in order to understand the impact of these different parameters on TOL corrosion.16 generic amines were tested as possible volatile corrosion inhibitor (VCI...

Full description

Bibliographic Details
Main Author: Oehler, Mike C.
Format: Thesis
Language:English
Published: Curtin University 2012
Online Access:http://hdl.handle.net/20.500.11937/703
_version_ 1848743455818252288
author Oehler, Mike C.
author_facet Oehler, Mike C.
author_sort Oehler, Mike C.
building Curtin Institutional Repository
collection Online Access
description Top-of-the-Line (TOL) corrosion was investigated under different carbon dioxide partial pressures, acetic acid concentrations, and temperatures in order to understand the impact of these different parameters on TOL corrosion.16 generic amines were tested as possible volatile corrosion inhibitor (VCI) candidates in a variety of TOL corrosion test set-ups. Properties of a working TOL corrosion inhibitor were identified and TOL corrosion laboratory test methods were improved.
first_indexed 2025-11-14T05:45:51Z
format Thesis
id curtin-20.500.11937-703
institution Curtin University Malaysia
institution_category Local University
language English
last_indexed 2025-11-14T05:45:51Z
publishDate 2012
publisher Curtin University
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-7032017-02-20T06:41:33Z Top-of-the-line corrosion control by continuous chemical treatment Oehler, Mike C. Top-of-the-Line (TOL) corrosion was investigated under different carbon dioxide partial pressures, acetic acid concentrations, and temperatures in order to understand the impact of these different parameters on TOL corrosion.16 generic amines were tested as possible volatile corrosion inhibitor (VCI) candidates in a variety of TOL corrosion test set-ups. Properties of a working TOL corrosion inhibitor were identified and TOL corrosion laboratory test methods were improved. 2012 Thesis http://hdl.handle.net/20.500.11937/703 en Curtin University fulltext
spellingShingle Oehler, Mike C.
Top-of-the-line corrosion control by continuous chemical treatment
title Top-of-the-line corrosion control by continuous chemical treatment
title_full Top-of-the-line corrosion control by continuous chemical treatment
title_fullStr Top-of-the-line corrosion control by continuous chemical treatment
title_full_unstemmed Top-of-the-line corrosion control by continuous chemical treatment
title_short Top-of-the-line corrosion control by continuous chemical treatment
title_sort top-of-the-line corrosion control by continuous chemical treatment
url http://hdl.handle.net/20.500.11937/703