Portuguese Study Of Mean Glandular Dose In Mammography And Comparison With European References

To characterise the mean glandular dose (MGD) in a sample of healthcare providers for digital mammography in Portugal. To compare the achieved values with European references. The MGD was measured on a poly-methyl-methacrylate phantom (45 mm) for each system using dosimeters. In addition, MGD was es...

Full description

Bibliographic Details
Main Authors: Sá dos Reis, Cláudia, Fartaria, M., Garcia Alves, J., Pascoal, A.
Format: Journal Article
Published: Oxford University Press 2018
Online Access:http://hdl.handle.net/20.500.11937/70259
_version_ 1848762257210605568
author Sá dos Reis, Cláudia
Fartaria, M.
Garcia Alves, J.
Pascoal, A.
author_facet Sá dos Reis, Cláudia
Fartaria, M.
Garcia Alves, J.
Pascoal, A.
author_sort Sá dos Reis, Cláudia
building Curtin Institutional Repository
collection Online Access
description To characterise the mean glandular dose (MGD) in a sample of healthcare providers for digital mammography in Portugal. To compare the achieved values with European references. The MGD was measured on a poly-methyl-methacrylate phantom (45 mm) for each system using dosimeters. In addition, MGD was estimated using exposure settings collected from mammography exams in clinical context. Data were collected from 25 computed-radiography systems (CR) and 13 integrated digital (DR). For both measurements (phantom and clinical exposures), the average MGD for CR was higher compared to the DR. For CR the mean MGD was 1.85 mGy (CC projection) and 2.10 mGy (MLO projection). For DR systems the corresponding values were 1.54 mGy (CC) and 1.68 mGy (MLO). The average MGD obtained using both methods and for both technologies is within the acceptable reference range proposed by European guidelines (<2.5 mGy). Dose Reference Levels implementation should be the next step to optimise mammography practice in Portugal.
first_indexed 2025-11-14T10:44:41Z
format Journal Article
id curtin-20.500.11937-70259
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T10:44:41Z
publishDate 2018
publisher Oxford University Press
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-702592018-10-02T01:38:52Z Portuguese Study Of Mean Glandular Dose In Mammography And Comparison With European References Sá dos Reis, Cláudia Fartaria, M. Garcia Alves, J. Pascoal, A. To characterise the mean glandular dose (MGD) in a sample of healthcare providers for digital mammography in Portugal. To compare the achieved values with European references. The MGD was measured on a poly-methyl-methacrylate phantom (45 mm) for each system using dosimeters. In addition, MGD was estimated using exposure settings collected from mammography exams in clinical context. Data were collected from 25 computed-radiography systems (CR) and 13 integrated digital (DR). For both measurements (phantom and clinical exposures), the average MGD for CR was higher compared to the DR. For CR the mean MGD was 1.85 mGy (CC projection) and 2.10 mGy (MLO projection). For DR systems the corresponding values were 1.54 mGy (CC) and 1.68 mGy (MLO). The average MGD obtained using both methods and for both technologies is within the acceptable reference range proposed by European guidelines (<2.5 mGy). Dose Reference Levels implementation should be the next step to optimise mammography practice in Portugal. 2018 Journal Article http://hdl.handle.net/20.500.11937/70259 10.1093/rpd/ncx300 Oxford University Press restricted
spellingShingle Sá dos Reis, Cláudia
Fartaria, M.
Garcia Alves, J.
Pascoal, A.
Portuguese Study Of Mean Glandular Dose In Mammography And Comparison With European References
title Portuguese Study Of Mean Glandular Dose In Mammography And Comparison With European References
title_full Portuguese Study Of Mean Glandular Dose In Mammography And Comparison With European References
title_fullStr Portuguese Study Of Mean Glandular Dose In Mammography And Comparison With European References
title_full_unstemmed Portuguese Study Of Mean Glandular Dose In Mammography And Comparison With European References
title_short Portuguese Study Of Mean Glandular Dose In Mammography And Comparison With European References
title_sort portuguese study of mean glandular dose in mammography and comparison with european references
url http://hdl.handle.net/20.500.11937/70259