Detecting incipient radial deformations of power transformer windings using polar plot and digital image processing

One of the main drawbacks of the frequency response analysis (FRA) technique that is widely accepted as the most reliable tool to detect transformer internal mechanical deformations is the inconsistent interpretation of the measured signature because of its reliance on personal expertise more than s...

Full description

Bibliographic Details
Main Authors: Abu-Siada, Ahmed, Aljohani, O.
Format: Journal Article
Published: Institution of Engineering and Technology 2018
Online Access:http://hdl.handle.net/20.500.11937/69867
_version_ 1848762154427088896
author Abu-Siada, Ahmed
Aljohani, O.
author_facet Abu-Siada, Ahmed
Aljohani, O.
author_sort Abu-Siada, Ahmed
building Curtin Institutional Repository
collection Online Access
description One of the main drawbacks of the frequency response analysis (FRA) technique that is widely accepted as the most reliable tool to detect transformer internal mechanical deformations is the inconsistent interpretation of the measured signature because of its reliance on personal expertise more than standard codes. Moreover, conventional FRA signature has a very low accuracy in detecting incipient and low mechanical fault levels. In order to avoid inconsistent interpretation for the transformer FRA signatures and improve its accuracy to detect minor fault levels, a reliable automated technique has become essential. This study investigates the feasibility of utilising FRA polar plot to detect minor radial deformation levels within two, three-phase power transformers of different ratings and winding configurations simulated using three-dimensional finite-element analysis software. Simulation results are validated through experimental measurements. Results of this study are also compared with the results obtained for other types of transformer winding deformations that are published in the literature in order to identify unique impact for each fault type on the proposed method. Findings reveal the superiority of the proposed approach over existing conventional technique in terms of accurate identification and quantification for minor transformer winding deformations.
first_indexed 2025-11-14T10:43:03Z
format Journal Article
id curtin-20.500.11937-69867
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T10:43:03Z
publishDate 2018
publisher Institution of Engineering and Technology
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-698672018-09-04T00:09:53Z Detecting incipient radial deformations of power transformer windings using polar plot and digital image processing Abu-Siada, Ahmed Aljohani, O. One of the main drawbacks of the frequency response analysis (FRA) technique that is widely accepted as the most reliable tool to detect transformer internal mechanical deformations is the inconsistent interpretation of the measured signature because of its reliance on personal expertise more than standard codes. Moreover, conventional FRA signature has a very low accuracy in detecting incipient and low mechanical fault levels. In order to avoid inconsistent interpretation for the transformer FRA signatures and improve its accuracy to detect minor fault levels, a reliable automated technique has become essential. This study investigates the feasibility of utilising FRA polar plot to detect minor radial deformation levels within two, three-phase power transformers of different ratings and winding configurations simulated using three-dimensional finite-element analysis software. Simulation results are validated through experimental measurements. Results of this study are also compared with the results obtained for other types of transformer winding deformations that are published in the literature in order to identify unique impact for each fault type on the proposed method. Findings reveal the superiority of the proposed approach over existing conventional technique in terms of accurate identification and quantification for minor transformer winding deformations. 2018 Journal Article http://hdl.handle.net/20.500.11937/69867 10.1049/iet-smt.2017.0412 Institution of Engineering and Technology fulltext
spellingShingle Abu-Siada, Ahmed
Aljohani, O.
Detecting incipient radial deformations of power transformer windings using polar plot and digital image processing
title Detecting incipient radial deformations of power transformer windings using polar plot and digital image processing
title_full Detecting incipient radial deformations of power transformer windings using polar plot and digital image processing
title_fullStr Detecting incipient radial deformations of power transformer windings using polar plot and digital image processing
title_full_unstemmed Detecting incipient radial deformations of power transformer windings using polar plot and digital image processing
title_short Detecting incipient radial deformations of power transformer windings using polar plot and digital image processing
title_sort detecting incipient radial deformations of power transformer windings using polar plot and digital image processing
url http://hdl.handle.net/20.500.11937/69867