A case study on the structural assessment of fire damaged building

© Published under licence by IOP Publishing Ltd. This paper presents a case study on the structural assessment of building damaged by fire and discussed on the site investigations and test results prior to determine the existing condition of the building. The building was on fire for about one hour...

Full description

Bibliographic Details
Main Authors: Osman, M., Sarbini, N., Ibrahim, I., Ma, C., Ismail, Mohamed, Mohd, M.
Format: Conference Paper
Published: 2017
Online Access:http://hdl.handle.net/20.500.11937/67870
_version_ 1848761680710860800
author Osman, M.
Sarbini, N.
Ibrahim, I.
Ma, C.
Ismail, Mohamed
Mohd, M.
author_facet Osman, M.
Sarbini, N.
Ibrahim, I.
Ma, C.
Ismail, Mohamed
Mohd, M.
author_sort Osman, M.
building Curtin Institutional Repository
collection Online Access
description © Published under licence by IOP Publishing Ltd. This paper presents a case study on the structural assessment of building damaged by fire and discussed on the site investigations and test results prior to determine the existing condition of the building. The building was on fire for about one hour before it was extinguished. In order to ascertain the integrity of the building, a visual inspection was conducted for all elements (truss, beam, column and wall), followed by non-destructive, load and material tests. The load test was conducted to determine the ability of truss to resist service load, while the material test to determine the residual strength of the material. At the end of the investigation, a structural analysis was carried out to determine the new factor of safety by considering the residual strength. The highlighted was on the truss element due to steel behaviour that is hardly been predicted. Meanwhile, reinforced concrete elements (beam, column and wall) were found externally affected and caused its strength to be considered as sufficient for further used of building. The new factor of safety is equal to 2, considered as the minimum calculated value for the truss member. Therefore, this fire damaged building was found safe and can be used for further application.
first_indexed 2025-11-14T10:35:32Z
format Conference Paper
id curtin-20.500.11937-67870
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T10:35:32Z
publishDate 2017
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-678702018-05-18T08:05:33Z A case study on the structural assessment of fire damaged building Osman, M. Sarbini, N. Ibrahim, I. Ma, C. Ismail, Mohamed Mohd, M. © Published under licence by IOP Publishing Ltd. This paper presents a case study on the structural assessment of building damaged by fire and discussed on the site investigations and test results prior to determine the existing condition of the building. The building was on fire for about one hour before it was extinguished. In order to ascertain the integrity of the building, a visual inspection was conducted for all elements (truss, beam, column and wall), followed by non-destructive, load and material tests. The load test was conducted to determine the ability of truss to resist service load, while the material test to determine the residual strength of the material. At the end of the investigation, a structural analysis was carried out to determine the new factor of safety by considering the residual strength. The highlighted was on the truss element due to steel behaviour that is hardly been predicted. Meanwhile, reinforced concrete elements (beam, column and wall) were found externally affected and caused its strength to be considered as sufficient for further used of building. The new factor of safety is equal to 2, considered as the minimum calculated value for the truss member. Therefore, this fire damaged building was found safe and can be used for further application. 2017 Conference Paper http://hdl.handle.net/20.500.11937/67870 10.1088/1757-899X/271/1/012100 restricted
spellingShingle Osman, M.
Sarbini, N.
Ibrahim, I.
Ma, C.
Ismail, Mohamed
Mohd, M.
A case study on the structural assessment of fire damaged building
title A case study on the structural assessment of fire damaged building
title_full A case study on the structural assessment of fire damaged building
title_fullStr A case study on the structural assessment of fire damaged building
title_full_unstemmed A case study on the structural assessment of fire damaged building
title_short A case study on the structural assessment of fire damaged building
title_sort case study on the structural assessment of fire damaged building
url http://hdl.handle.net/20.500.11937/67870